9
INSTALLATION
6.4
Sensor connection
Fix the connectors to the relevant functions according to the initials indicated in your assembly general diagram (par. 5.1).
Harness cables are marked with a symbol denoting their functions: please see the table for correct harness connection.
Use ARAG sensors: use of unsuitable sensors not provided by ARAG automatically voids the warranty.
ARAG is not liable for damage to the equipment, persons or animals caused by failure to observe the above instructions.
ITEM
MAIN CONNECTION
ALTERNATIVE
CONNECTION
F
Flowmeter
-
M
Pressure sensor
-
S
Speed sensor
-
T
Filling flowmeter
Level sensor
X
RPM sensor
-
- The products are supplied with the sensor installation instructions.
The following speed sensors can also be used as RPM sensors:
• inductive speed sensor
(code 467100.086)
;
• magnetic speed sensor
(code 467100.100)
.
- Connection of:
• flowmeter;
• pressure sensor;
• level sensor
• filling flowmeter;
• RPM sensor.
All ARAG sensors use the same type of connector. Connect the sensor connector to the relevant harness; make sure it is correctly fitted and push it
until locking it.
Fig. 12
Fig. 13
6.5
Auxiliary functions
Depending on the auxiliary functions requested, various harnesses are available for connecting cameras, spraying activation
signal and treatment status (ARAG general catalog).
• Camera connection
Bravo 400S LT can be connected to one or two cameras
code 46700100
(purchased separately) using the suitable cables listed in the ARAG general
catalog. Connect the connector to the computer (see connection points at par. 5.2) and the other cable end to the camera: ensure it is correctly in
place and turn the ring nut clockwise until blocking it.
• Enable spraying
The harness that connects Bravo 400S LT to a spraying activation control is available on the ARAG general catalog.
CABLE
COLOR
FUNCTION
LABEL
STATUS
1
RED
Enable spraying
SERVICE IN
Active low
2
GREEN
General status
SERVICE OUT
12Vdc
3
BLACK
Ground
GND
--
Fig. 14