background image

INSTALLATION

4674L0701

4674L0713

COMPUTER BRAVO 400S LT

WITH INTEGRATED GPS NAVIGATOR

Summary of Contents for Bravo 400S LT

Page 1: ...INSTALLATION 4674L0701 4674L0713 COMPUTER BRAVO 400S LT WITH INTEGRATED GPS NAVIGATOR...

Page 2: ...Position on farming machine 4 5 1 System recommended composition 4 5 2 Computer positioning 5 5 3 Bracket fixing 6 5 4 Control unit position 6 5 5 Hydraulic unit positioning 6 6 Wiring connections 7 6...

Page 3: ...tic compatibility Forestry and farming machines harmonized with 2004 108 EC Directive 3 PRECAUTIONS Do not aim water jets at the equipment Do not use solvents or fuel to clean the case outer surface D...

Page 4: ...M Pressure sensor P Control valve S Speed sensor T Filling flowmeter Level sensor V1 Camera 1 V2 Camera 2 X RPM sensor 1 7 Section valves ASSEMBLY DIAGRAM FOR CROP SPRAYER WITH CENTRIFUGAL PUMP Fig 4...

Page 5: ...reach by hand bear in mind that the computer should not obstruct the operator s freedom of movement or block his view Consider all necessary connections of the computer Fig 5 the cable length and mak...

Page 6: ...tion The control unit must be fixed with the special brackets supplied and fitted to the unit positioning it as shown in the manual provided with the assembly MAKE SURE TO FOLLOW ALL THE SAFETY INSTRU...

Page 7: ...y failure to observe the above instructions 6 1 General precautions for a correct harness position Securing the cables secure the harness so that it does not interfere with moving parts route the harn...

Page 8: ...ing to the initials indicated in your assembly general diagram par 5 1 System recommended composition Remove the protection cap 1 Fig 10 from the electric valve Place the seal 2 onto the connector 3 a...

Page 9: ...e sensor level sensor filling flowmeter RPM sensor All ARAG sensors use the same type of connector Connect the sensor connector to the relevant harness make sure it is correctly fitted and push it unt...

Page 10: ...achine battery 12 Vdc ALWAYS switch on the computer through the monitor and then remember to switch it off using the specific key on the control panel If Bravo 400S LT remains on for a long time with...

Page 11: ...20 Fig 21 Insertion Insert the memory card making sure to orient it correctly the card cut edge A must be face down Push the card until it engages into place and close the slot with the cover Removal...

Page 12: ...umption valves excluded 0 5 A 12 Vdc Operating temperature 0 C 45 C 32 F 113 F Storage temperature 10 C 60 C 14 F 140 F Weight without cables 1300 g cod 4674L0701 1720 g cod 4674L0713 Digital inputs f...

Page 13: ...other conditions damage due to the use of unsuitable chemical products for spraying watering weedkilling or any other crop treatment that may damage the apparatus malfunctioning caused by negligence m...

Page 14: ...a Palladio 5 A Tel 39 0522 622011 Fax 39 0522 628944 http www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are m...