15
GB
5.6
Wiring connections
To connect the valve, use the cable with Tyco Superseal® 4-pole connector for CAN-BUS.
1
2
3
4
1
GND
2
+12 Vdc
3
CAN L
4
CAN H
Fig. IX
Connect the valve connector to that of the relevant harness; make sure it is correctly fitted and push
it until it locks in place (
).
WARNING: CHECK THAT THE CONNECTOR IS FITTED CORRECTLY TO ENSURE A
PROPER SEALING.
WARNING: If the gasket is not positioned correctly, there may be infiltrations of water
in the connector and in the valve, with the consequent risk of damage to the device.
6
USE
6.1
Commands
The specifications of SAEJ1939 and A-Net protocols to send commands to the valve can be
requested by contacting the ARAG technical support department to the following address: support@
aragnet.com.
6.2
LED signals
A LED positioned on valve connector indicates the relevant status:
GREEN BLINKING
An intermittent flashing lasting 10 seconds indicates that the valve is
waiting to acquire a CAN-BUS address.
After the aforementioned
period, the LED turns solid green, even if the address has not yet
been acquired
.
GREEN STEADY
ON
The valve is configured and functioning.
RED
BLINKING
A red flashing indicates a malfunction.
An error code is identified according to the number of blinks
(refer to