Vertical foam markers
5.6
Mounting the pneumo-hydraulic circuit
- Connect the white tube (air) and the blue tube (fluid) to the foam marker which is the farthest from
the compressor unit. Ensure that each tube is connected to a connector of the same color.
- Lay the piping along the framework of the boom as far as the electric compressor unit, leaving
plenty of it by the joints.
- Connect the tubes to the compressor unit ensuring that each tube is connected to a connector
of the same color.
- Connect the foam marker which is the nearest to the compressor unit and repeat the above
procedure.
- Connect the dark blue pipes (liquid) and the white ones (air) to the fittings of the same colour on
the tank cap.
- Cap the tank.
•
Drill two Ø 6 mm holes at a distance of 100 mm
on bar (
A
).
•
Fix the bracket (
B
) to the bar with the supplied
M6 screws.
•
Fit the foam maker (
D
) onto the knurled section
of the bar (
B
) and fix with the supplied screw
(
E
).
•
Repeat the operation with the other boom.
Fig. 7b
Fig. 8