7
4 USE
CAUTION:
For the implementation on already operating systems it is necessary to follow all safety
rules described herein. System assembly and start-up must be carried out by expert per
-
sonnel according to the safety rules so as to ensure the same safety level of the system
the control box is going to be installed in.
Push up the switch (ON position) to open the relevant valve and start the delivery. The LED ON
indicates the switch is in spraying position (Fig. 4).
5 MAINTENANCE
In case of failure, check the fuse and the wiring (Fig. 2).
5.1
Troubleshooting
FAULT
CAUSE
REMEDY
The LEDs turn on but are
unable to control the relevant
valves
Disconnected connectors
• Connect the connectors.
All LEDs are OFF and the
valves do not work
The internal protection is
active
• Cut-off the supply and wait for at least 20 seconds
before switching the control box on. If the problem
persists, please contact the nearest Assistance
Centre.
Burnt fuse inside electric
circuit (Fig. 2)
• Replace the fuse. If the problem persists, please
contact the nearest Assistance Centre.
Power supply failure
• Check power supply.
6
TECHNICAL DATA
Description
Control box for Seletron electric valves
Power supply
12 Vdc (Vmin 9 / Vmax 16)
Max. switching current per each output
1,5 A
Working temperature
-20 °C ÷ 55 °C / -4 °F ÷ +131 °F
Stocking temperature
-20 °C ÷ 55 °C / -4 °F ÷ +131 °F
Output protection through resettable fuse
•
Dimensions
80 x 115 x 93 mm (harness excluded)
Weight
742 g (harness included)
7
DISPOSAL AT THE END OF SERVICE
Dispose of the system in compliance with the established legislation in the country of use.
Tab. 1