Super Shuffle Operating Manual
15
Section 9: Troubleshooting
.Problem
Possible Cause
Solution
Unable to Communicate with IOB
a. Parallel cable is unplugged either from
the IOB or the Motherboard.
a. Check connections. Reattach cable if
necessary.
Lasers are blocked
Left Laser Blocked
Right Laser Blocked
Both Lasers Blocked
a. Laser is blocked.
b. Lasers unaligned.
c. Laser light is dim.
a. Remove blockage. If none is evident
check the laser and sensor ports. Clean
the sensor and laser.
b. See 7.1 for instructions.
c. Check connections for laser. Make sure
the laser is plugged in to the IOB. If it is
it could be a bad laser. Replace laser.
No Video
a. VGA Cable is not attached.
b. The power cable is not attached.
c. The external powerswitch on the back of
the Super Shuffle is switched to off.
d. The monitor is not plugged into the
junction box in the rear of the Super
Shuffle.
e. Power to the mainboard may be off.
f. Possible CMOS setting issue.
a. Check the connections at monitor and
the motherboard.
b. Check the connections at monitor and
the motherboard.
c. Flip the external power switch on the
back side of the Super Shuffle to
ON.
d. Make sure all connections are inplace
and secure.
e. Press the red button on the back of the
machine.
f. Check CMOS Power Setting. Change
APM configuration to Power On.
The Dollar Bill Accepter
is not Functioning
a. The powercord to the Dollar Bill
Accepter is not plugged in.
b. The Dollar Bill Accepter is not
configured properly.
a. Plug in the Dollar Bill Accepter
powercord into the powersupply
underneath the playing field. See
Section 7.4
.
b. Configure the Dollar Bill Accepter
using it’s manual.