Model 500T8G18
Rev B
25
Table 3-7. Catalog of Fault Codes Returned by RDFLT Command
(The RDFLT command causes the TWTA to return a string in the form flt=[
code
], where [
code
] is an ACSII
number whose meaning is given below).
Fault Code
Meaning
0 No
fault
7 System
Fault
8 Heater
Fault
9 Low
Line
10
Cathode overvoltage
11 Body
overcurrent
12 Cathode
undervoltage
15 Collector
undervoltage
16 Inverter
fault
17
Internal interlock open
18 Tube
arc
19 TWT
(hardware)
overtemperature
20
Power supply (hardware) overtemperature
22 External
inhibit
23
Over reflected power
26 Panel
Open
27 Latched
Fault
30 Grid
Overvoltage
49 TWT
(software)
overtemperature
50
Cabinet (software) overtemperature