3.8 REMOTE IEEE-488 OPERATION
The TWTA is provided with a communication interface that conforms electrically to the IEEE-488 standard.
It permits remote emulation of OPERATE, STANDBY, and RESET push-buttons as well as access to
parameter measurements, system faults, gain adjustment, and control unit status. The following tables
summarize the commands and the return codes.
Table 3-5. Catalog of IEEE-488 Commands
Command Function
Units
Response
format
RDSTAT
Returns status code of processing of previous command (see
Table 3-6)
STATUS=[
]
RDFLT
Returns system fault code (see Table 3-7)
flt=[ ]
OPERATE;
Emulates OPERATE push-button
STANDBY;
Emulate STANDBY push-button
POWER:OFF;
Emulate STANDBY push-button
RESET;
Emulates RESET softkey
RDS/N
Returns serial number
s/n=[ ]
RDCONHR
Returns console hours
ConHr=[ ]
RDRFHR
Returns RF hours
RfHr=[ ]
RDEK
Returns cathode voltage
KV
Ek=[ ]
RDEB
Returns collector voltage
KV
Eb=[ ]
RDEF
Returns heater voltage
V
Ef=[ ]
RDIF
Returns heater current
A
If=[ ]
RDIW
Returns helix current
mA
Iw=[ ]
RDTMPTWTF
Returns TWT temp (°F)
°F
TWTF=[ ]F
RDTMPTWTC
Returns TWT temp (°C)
°C
TWTC=[ ]C
RDTMPPSF
Returns power supply temp (°F)
°F
PSF=[ ]F
RDTMPPSC
Returns power supply temp (°C)
°C
PSC=[ ]C
RDTWTOTF
Returns TWT overtemp warning setpoint (°F)
°F
TWTOTF=[ ]F
STWTOTF
Sets TWT overtemp warning setpoint (°F)
°F
RDTWTOTC
Returns TWT overtemp warning setpoint (°C)
°C
TWTOTC=[ ]C
STWTOTC
Sets TWT overtemp warning setpoint (°C)
°C
RDPSOTF
Returns power supply overtemp warning setpoint (°F)
°F
PSOTF=[ ]F
SPSOTF
Sets p. s. overtemp warning setpoint (°F)
°F
RDPSOTC
Returns p. s. overtemp warning setpoint (°C)
°C
PSOTC=[ ]C
SPSOTC
Sets p. s. overtemp warning setpoint (°C)
°C
RDIWOC
Returns helix overcurrent warning setpoint
mA
IwOC=[ ]
SIWOC
Sets helix overcurrent warning setpoint
mA
RDLOGIC
Returns logic state code (see Table 3-8)
Sys=[ ]
RDA
Returns gain
%
A=[ ]
SA Sets
gain
%
RDHTDREM
Returns remaining heater time delay
sec.
HTD=[ ]s
RDPOD
Returns forward power out (dBm)
dBm
Po=[ ]dBm
RDPOW
Returns forward power out (W)
watts
Po=[ ]W
RDPRD
Returns reflected power out (dBm)
dBm
Pr=[ ]dBm
Summary of Contents for 10012342
Page 2: ......
Page 4: ......
Page 8: ......
Page 12: ......
Page 20: ......
Page 44: ...Model 500T8G18 30 Rev B ...
Page 48: ...Model 500T8G18 34 Rev B ...
Page 50: ...Model 500T8G18 36 Rev B ...
Page 56: ...Model 500T8G18 42 Rev B ...
Page 70: ...Model 500T8G18 56 Rev B ...
Page 72: ......