![AR 10012342 Operating And Service Manual Download Page 29](http://html1.mh-extra.com/html/ar/10012342/10012342_operating-and-service-manual_2962339029.webp)
Model 500T8G18
Rev B
15
3.3 FRONT PANEL FEATURES
Refer to Figure 3-3 below.
1
6
7
9
8
12
5
11
10
3
4
2
Figure 3-3. Front Panel Features
Table 3-2. Front Panel Features
Item Title
Function
1 MAIN
POWER
Switchable 15 A. circuit breaker; connects primary power-to-power supplies (3-
phase shown). Single-phase model uses 30A circuit breaker.
2. OPERATE
Push-button; turns on high voltage and SSA when all faults and heater delay are
cleared.
3.
STANDBY
Push-button; shuts off SSA and turns off high voltage.
4.
ADJUST
Rotary knob used as an input device to change values of a variety of parameters.
5. EXIT
Push-button; terminates various menu selection routines and returns to the previous
menu level.
6-9.
S1...S4
“Soft Key” push-buttons; various menu selection functions.
10.
Display
Displays numerous parameter values and fault messages.
11. Keylock
Switch
Allows operator to inhibit the TWTA, to enable front panel control, or to enable
computer control.
12.
Emergency switch cover
Provides access to emergency bypass switches, which permit manual control of the
amplifier.
Summary of Contents for 10012342
Page 2: ......
Page 4: ......
Page 8: ......
Page 12: ......
Page 20: ......
Page 44: ...Model 500T8G18 30 Rev B ...
Page 48: ...Model 500T8G18 34 Rev B ...
Page 50: ...Model 500T8G18 36 Rev B ...
Page 56: ...Model 500T8G18 42 Rev B ...
Page 70: ...Model 500T8G18 56 Rev B ...
Page 72: ......