Aquion RainSoft EC4 OXYTECH 150 PLUS MM Owner'S Manual Download Page 15

• Press the 

Menu Forward key

to advance to 

CURRENT DAY

; the

computer will display:

• Use the 

Adjust Up

and 

Adjust Down keys

to select the current day.

• Press the 

Menu Forward key

to advance to 

CURRENT DATE

; the

computer will display:

• Use the 

Adjust Up

and 

Adjust Down keys

to change the month.

• Press the 

Menu Forward key

to access the day. Use the 

Adjust Up

and 

Adjust Down keys

to change the day.

• Press the 

Menu Forward key

to access the year. Use the 

Adjust Up

and 

Adjust Down keys

to change the year.

• Press the 

Menu Forward key

to advance to 

AUTO DAYLIGHT

SAVINGS TIME

; the computer will display:

• To leave this setting 

ON

, press the 

Menu Forward key

to advance

to 

FILTER WK1

.

• To select 

OFF

, press the 

Adjust Up

or 

Adjust Down key

. Press the

Menu Forward key

to advance to 

FILTER WK1

; the computer

will display:

• Use the 

Adjust Up

and 

Adjust Down keys

to select 

ON 

or

OFF 

for

each day of the week. Use the 

Menu Forward key

to advance to

each day of the week.

• Press the 

Menu Forward key

to advance to 

FILTER WK2

; the

computer will display:

• Use the 

Adjust Up

and 

Adjust Down keys

to select 

ON 

or

OFF 

for

each day of the week. Use the 

Menu Forward key

to advance to

each day of the week.

• Press the 

Menu Forward key

to advance to 

TIME OF FILTER

REGEN

; the computer will display:

• Use the 

Adjust Up

or 

Adjust Down key

to change the hour of

regeneration, if desired.

• Press the 

Menu Forward key

to advance to 

TIME OF AIR REGEN

;

the computer will display:

• Use the 

Adjust Up

or 

Adjust Down key

to change the hour of

regeneration, if desired.

• Press the 

Menu Forward key

to advance to 

NUMBER OF PURGE

;

the computer will display:

• Use the 

Adjust Up

or 

Adjust Down key

to change the number of

air purges per day, if desired.

• Press the 

Menu Forward key

to exit the Customer Settings.

CURRENT DATE

AUTO DAYLIGHT SAVINGS TIME: ON

FILTER WK1: ON    SU  TU  TH  S

FILTER WK2: ON    M  W  F

Helpful Tip: If auto daylight savings time is
“ON”, the system will automatically adjust
the clock in the spring and fall. Only set the
daylight savings time to “OFF” if daylight
savings time is not observed in your area.

Helpful Tip: Use the Menu Back key to edit
your selection.

Helpful Tip: We recommend the default
setting of every other day.

Helpful Tip: We recommend the default
setting of every other day.

TIME OF FILTER REGEN: 11:00 

P

.

M

.

Helpful Tip: Filter default setting is 11:00 

P

.

M

.

We recommend that you do not change the
default setting. Changing the default
setting may interfere with other RainSoft
products. The filter and air regenerations
should not be set for the same time of day.

TIME OF FILTER REGEN: 1:00 

A

.

M

.

Helpful Tip: Air default setting is 1:00 

A

.

M

.

We recommend that you do not change the
default setting. Changing the default
setting may interfere with other RainSoft
products. The filter and air regenerations
should not be set for the same time of day.

NUMBER OF PURGE: 1 PER DAY

15

CURRENT DAY

Helpful Tip: We recommend the default
setting of once per day. Multiple purges per
day may be required for high levels of iron
or hydrogen sulfide.

Summary of Contents for RainSoft EC4 OXYTECH 150 PLUS MM

Page 1: ...EC C4 4 O OX XY YT TE EC CH H C Ch he em mi ic ca al l f fr re ee e i ir ro on n s su ul lf fu ur r a an nd d m ma an ng ga an ne es se e r re ed du uc ct ti io on n W WA AT TE ER R T TR RE EA AT TM M...

Page 2: ...fication Information 4 Installation Instructions 5_11 System Start Up 12 Understanding the Customer Settings 13 Programming the Customer Settings 14 15 Understanding a Manual Regeneration 16 System Al...

Page 3: ...ld be limited to a maximum of 1 0 ppm Operational Specifications Plumbing 3 4 to 11 4 Drain Line 1 2 Water Pressure 20 psi 120 psi 137 89 kPa 827 37 kPa Actual Influent Flow Rate Water available from...

Page 4: ...alarms press any key on the computer Maintenance Requirements Cleaning the Valves Annually Your system will sound an alarm when this service is required Please follow the on screen prompts and contact...

Page 5: ...well pump flow rate 4 Locate a Site for the System The installation site must have a level smooth and clean surface see Figure 1 The two tanks should be installed after the pressure tank and as close...

Page 6: ...2 WARNING THE RISER PIPES ARE NOT INTERCHANGEABLE Close off the top of the filter tank riser pipe see Helpful Tip With the funnel provided add fills 1 4 to the filter tank see Figure 3 Before adding...

Page 7: ...alve O ring seals against the aeration tank WARNING THE CONTROL VALVES ARE NOT INTERCHANGEABLE 7 Turn Off the Water and Drain the Plumbing Turn off the water at the meter or the pressure tank Open all...

Page 8: ...1 check valve on the raw water supply feeding the aeration tank see Figures 5 1 5 2 The check valve must be installed in vertical upflow position with a minimum 12 water column above the check valve s...

Page 9: ...t pipes with water in them or while attached to the system steam will damage the plastic parts in the valves Do not point the soldering torch directly at the tanks or valves These composite mate rials...

Page 10: ...ing and air in take screen see Figure 9 After assembly push the elbow into the brass adapter see Figure 9 Run the drain lines to an approved air gap and drain see Figure 10 SPRING CLIP 1 2 DRAIN LINE...

Page 11: ...gether see Figure 12 One way connection only Plug the 24VAC transformer into a 110 VAC 60 Hz or 230 VAC 50 Hz outlet The installation is complete Please proceed to System Startup on page 12 11 Importa...

Page 12: ...l will display Press the Enter key to select NOW the computer will provide a 10 second countdown before regeneration During regeneration the aeration system will purge water from the aeration tank and...

Page 13: ...lt setting may interfere with other RainSoft products The filter and air regenerations should not be set for the same time of day Time of Air Regeneration Sets the time of day only on the hour that th...

Page 14: ...TIME OF DAY the computer will display Use the Adjust Up and Adjust Down keys to change the hour of day Press the Menu Forward key to access the minutes of day Use the Adjust Up and Adjust Down keys to...

Page 15: ...R REGEN the computer will display Use the Adjust Up or Adjust Down key to change the hour of regeneration if desired Press the Menu Forward key to advance to NUMBER OF PURGE the computer will display...

Page 16: ...will provide a 10 second countdown before regeneration To select LATER press the Menu Forward key and then the Enter key the computer will display 16 MANUAL REGEN FILTER AIR BOTH FILTER REGEN NOW OR...

Page 17: ...ration Avg Water Use Displays the average water use gallons per day Current Flow Rate Displays the flow rate through the system when water is used gallons per minute Vacation Mode Displays the ON OFF...

Page 18: ...18 Filter Valve Exploded View 19 25 12 13 A B 22 14 3 2 1 4 5 7 8 6 24 21 20 23 18 16 17 18 15 11 10 9...

Page 19: ...Aeration Valve Exploded View 38 36 37 22 33 29 28 27 21 C 7 8 6 5 4 13 14 2 12 1 11 15 9 10 3 17 16 18 30 31 32 19...

Page 20: ...20 Filter Control Exploded View 11 8 9 Pin 1 2 3 Pin 1 2 10 6B 6A 5 1 5 4 7...

Page 21: ...21 Aeration Control Exploded View Pin 3 2 1 Pin 2 1 2 3 7 4 5 1 8 5 12 8 6A 6B 13 14...

Page 22: ...2 17950 INJECTOR CAP SOFTENER 17 4 17951 10 24 X 1 SCREW HEX WASHER HEAD 18 2 17617 C INJECTOR PLUG ASSEMBLY 19 2 17557 COMPOSITE BYPASS VALVE 20 2 17958 O RING 015 21 2 13329 O RING 014 22 1 17939 1...

Page 23: ...19536 SEALED SWITCH C NC MALE CONNECTOR RED 6B 2 19537 SEALED SWITCH C NO FEMALE CONN BROWN 7 4 18135 4 X 1 1 4 SLOTTED HEX WASHER TYPE 25 8 6 17542 4 20 X 3 8 SCR PAN H PHIL SS 9 1 19732 OUTDOOR EC4...

Page 24: ...er for service 1 Reset the time of day hour of regenerations 2 Verify that auto daylight savings time is set to ON 2 Systems regenerate at the wrong time 1 The raw water has changed 2 The bypass valve...

Page 25: ...itation of incidental or consequential damages so parts of the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which...

Page 26: ...26 26 26 26 26 NOTES NOTES...

Page 27: ...27 NOTES...

Page 28: ...inSoft Division of Aquion Inc 2080 East Lunt Avenue Elk Grove Village Illinois 60007 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2011 RAINSOFT DIVISION OF AQUION I...

Reviews: