13

Understanding the Customer Settings

Programming Options

Vacation Mode:

Puts the system into hibernation while you are on

vacation or gone for extended period of time.

System Alarm:

Sets the audio alarm to “ON/OFF” and the time it will

sound. The default setting for “ON” is 5:00 

P

.

M

.

Time of Day:

Sets the current time of day.

Current Day:

Sets the current day of the week.

Current Date:

Sets the current date by month/day/year.

Auto Daylight Savings Time:

Allows the computer to automati-

cally adjust for daylight savings time in applicable areas. The default
setting is “ON”.

Filter Schedule WK1/WK2: 

Sets the days of the week that the filter

will clean. The default setting is every other day, starting with
Sunday.

Time of Filter Regeneration:

Sets the time of day (only on the

hour) that the filter will regenerate/clean. The default setting is
11:00 

P

.

M

. We recommend that you do not change the default

setting. Changing the default setting may interfere with other
RainSoft products. The filter and air regenerations should not be set
for the same time of day.

Time of Air Regeneration:

Sets the time of day (only on the hour)

that the computer will replenish the air pocket. The air default
setting is 1:00 

A

.

M

. We recommend that you do not change the

default setting. Changing the default setting may interfere with
other RainSoft products. The filter and air regenerations should not
be set for the same time of day.

Number of Air Purges:

Sets the number of times the air will purge

and replenish per day. The default setting is one purge at 1:00 

A

.

M

.

One purge = every 24 hours; Two purges = every 12 hours; Three
purges = every 8 hours; Four purges = every 6 hours.

Menu Forward

and 

Menu Back

keys

: Use to scroll through the list

of functions or to change the
menu choice.

Info Center key:

Use to access the

Information Center.

Manual Regeneration key:

Use to

initiate a manual regeneration.

Enter key:

Use to select or enter

the menu of choice.

Adjust Up and Adjust Down keys:

Use to alter the blinking value.

Customer Settings key:

Use to

access the Customer Settings.

Summary of Contents for RainSoft EC4 OXYTECH 150 PLUS MM

Page 1: ...EC C4 4 O OX XY YT TE EC CH H C Ch he em mi ic ca al l f fr re ee e i ir ro on n s su ul lf fu ur r a an nd d m ma an ng ga an ne es se e r re ed du uc ct ti io on n W WA AT TE ER R T TR RE EA AT TM M...

Page 2: ...fication Information 4 Installation Instructions 5_11 System Start Up 12 Understanding the Customer Settings 13 Programming the Customer Settings 14 15 Understanding a Manual Regeneration 16 System Al...

Page 3: ...ld be limited to a maximum of 1 0 ppm Operational Specifications Plumbing 3 4 to 11 4 Drain Line 1 2 Water Pressure 20 psi 120 psi 137 89 kPa 827 37 kPa Actual Influent Flow Rate Water available from...

Page 4: ...alarms press any key on the computer Maintenance Requirements Cleaning the Valves Annually Your system will sound an alarm when this service is required Please follow the on screen prompts and contact...

Page 5: ...well pump flow rate 4 Locate a Site for the System The installation site must have a level smooth and clean surface see Figure 1 The two tanks should be installed after the pressure tank and as close...

Page 6: ...2 WARNING THE RISER PIPES ARE NOT INTERCHANGEABLE Close off the top of the filter tank riser pipe see Helpful Tip With the funnel provided add fills 1 4 to the filter tank see Figure 3 Before adding...

Page 7: ...alve O ring seals against the aeration tank WARNING THE CONTROL VALVES ARE NOT INTERCHANGEABLE 7 Turn Off the Water and Drain the Plumbing Turn off the water at the meter or the pressure tank Open all...

Page 8: ...1 check valve on the raw water supply feeding the aeration tank see Figures 5 1 5 2 The check valve must be installed in vertical upflow position with a minimum 12 water column above the check valve s...

Page 9: ...t pipes with water in them or while attached to the system steam will damage the plastic parts in the valves Do not point the soldering torch directly at the tanks or valves These composite mate rials...

Page 10: ...ing and air in take screen see Figure 9 After assembly push the elbow into the brass adapter see Figure 9 Run the drain lines to an approved air gap and drain see Figure 10 SPRING CLIP 1 2 DRAIN LINE...

Page 11: ...gether see Figure 12 One way connection only Plug the 24VAC transformer into a 110 VAC 60 Hz or 230 VAC 50 Hz outlet The installation is complete Please proceed to System Startup on page 12 11 Importa...

Page 12: ...l will display Press the Enter key to select NOW the computer will provide a 10 second countdown before regeneration During regeneration the aeration system will purge water from the aeration tank and...

Page 13: ...lt setting may interfere with other RainSoft products The filter and air regenerations should not be set for the same time of day Time of Air Regeneration Sets the time of day only on the hour that th...

Page 14: ...TIME OF DAY the computer will display Use the Adjust Up and Adjust Down keys to change the hour of day Press the Menu Forward key to access the minutes of day Use the Adjust Up and Adjust Down keys to...

Page 15: ...R REGEN the computer will display Use the Adjust Up or Adjust Down key to change the hour of regeneration if desired Press the Menu Forward key to advance to NUMBER OF PURGE the computer will display...

Page 16: ...will provide a 10 second countdown before regeneration To select LATER press the Menu Forward key and then the Enter key the computer will display 16 MANUAL REGEN FILTER AIR BOTH FILTER REGEN NOW OR...

Page 17: ...ration Avg Water Use Displays the average water use gallons per day Current Flow Rate Displays the flow rate through the system when water is used gallons per minute Vacation Mode Displays the ON OFF...

Page 18: ...18 Filter Valve Exploded View 19 25 12 13 A B 22 14 3 2 1 4 5 7 8 6 24 21 20 23 18 16 17 18 15 11 10 9...

Page 19: ...Aeration Valve Exploded View 38 36 37 22 33 29 28 27 21 C 7 8 6 5 4 13 14 2 12 1 11 15 9 10 3 17 16 18 30 31 32 19...

Page 20: ...20 Filter Control Exploded View 11 8 9 Pin 1 2 3 Pin 1 2 10 6B 6A 5 1 5 4 7...

Page 21: ...21 Aeration Control Exploded View Pin 3 2 1 Pin 2 1 2 3 7 4 5 1 8 5 12 8 6A 6B 13 14...

Page 22: ...2 17950 INJECTOR CAP SOFTENER 17 4 17951 10 24 X 1 SCREW HEX WASHER HEAD 18 2 17617 C INJECTOR PLUG ASSEMBLY 19 2 17557 COMPOSITE BYPASS VALVE 20 2 17958 O RING 015 21 2 13329 O RING 014 22 1 17939 1...

Page 23: ...19536 SEALED SWITCH C NC MALE CONNECTOR RED 6B 2 19537 SEALED SWITCH C NO FEMALE CONN BROWN 7 4 18135 4 X 1 1 4 SLOTTED HEX WASHER TYPE 25 8 6 17542 4 20 X 3 8 SCR PAN H PHIL SS 9 1 19732 OUTDOOR EC4...

Page 24: ...er for service 1 Reset the time of day hour of regenerations 2 Verify that auto daylight savings time is set to ON 2 Systems regenerate at the wrong time 1 The raw water has changed 2 The bypass valve...

Page 25: ...itation of incidental or consequential damages so parts of the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which...

Page 26: ...26 26 26 26 26 NOTES NOTES...

Page 27: ...27 NOTES...

Page 28: ...inSoft Division of Aquion Inc 2080 East Lunt Avenue Elk Grove Village Illinois 60007 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2011 RAINSOFT DIVISION OF AQUION I...

Reviews: