background image

4

SAVE THESE INSTRUCTIONS

division™ skimmers are made in conformity with the national and international security laws

.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

 

1)  Check that the current on the pump’s label matches the outlet current. The pump has a differential 

switch (protector) through which the nominal current must be lower or equal to 30 mA.

2) 

Never operate the pump without water to avoid damage to the pump motor.

3)  Before plugging in the pump, check that the cord and pump are not damaged.
4)  The pump has a type Z cable link. The cable and plug cannot be substituted or repaired. In case 

of damage, replace the entire pump

5)  CAUTION: disconnect all submerged electrical products before doing maintenance in the 

water; in case the plug or electrical outlet is damaged, switch off the circuit breaker before 

disconnecting the plug from the outlet.

6)  This appliance 

can be run in liquids or in any environment with a maximum temperature of 

35°C/95° F.

7) 

Do not use for purposes (

i.e. in bathroom or similar applications) 

other than for which it was 

designed.

8) 

Avoid use with corrosive or abrasive liquids.

9)  This appliance has not been designed for use by children or mentally challenged individuals. 

Appropriate adult supervision or persons responsible for personal safety is required.

10) 

Do not disconnect from an electrical outlet by pulling the cord.

11) 

The filter can only be used in the above-mentioned applications and is only for indoor use.

12)  This appliance has no user serviceable parts. 

 

INSTRUCTIONS FOR THE CORRECT DISPOSAL OF THE PRODUCT ACCORDING TO EU DIRECTIVE 
2002/96/EC

When used or broken, this product does not have to be disposed with other waste. It can be 
delivered to specific electrical waste collection centers or to dealers who provide this service. 

Disposal of electrical products separately avoids negative consequences for the environment 

and for overall public health and allows the reuse of materials providing savings of energy and 

resources.

LIMITED WARRANTY

Seachem guarantees this product (see Exclusions below) to the original purchaser against defects of 
materials and workmanship for a period of five (5) years from the date of original purchase, except for 
the pump’s impeller, which is guaranteed for a period of six (6) months.  This warranty is limited to repair 
or replacement (at Seachem’s option) of defective product only and does not cover loss of aquarium life, 

personal injury, property loss, or damage arising from the use of the product.  You must retain original 

Summary of Contents for division 125

Page 1: ...division 125 250 500 User Manual...

Page 2: ...or de meest recente en of meertalige versie van deze gebruikershandleiding naar www aquavitro com downloads manuals division skimmers pdf DE Die aktuellste und oder mehrsprachigste Version dieses Benu...

Page 3: ...alongthecordandcomingincontactwiththereceptacle Iftheplugorreceptacledoes get wet DON T unplug the cord Disconnect the fuse or circuit breaker that supplies power to appliance Then unplug and examine...

Page 4: ...y children or mentally challenged individuals Appropriate adult supervision or persons responsible for personal safety is required 10 Do not disconnect from an electrical outlet by pulling the cord 11...

Page 5: ...tingfrommodification tamperingwithorattemptedrepairbyanyoneother than Seachem or its designee Transfer of the product to someone other than the original purchaser Subjecting the product to electrical...

Page 6: ...then extracted from the aquarium water the overall organic load of the aquarium is decreased Additionally the division series protein skimmer will increase oxygen content in the system increase oxida...

Page 7: ...eaction Column C onto the Support Base A 2 Apply the Locking Ring B around the connection point of the Reaction Column C to the Support Base A 3 Press the Venturi Injector L into the intake of the Pum...

Page 8: ...Silencer F 13 Insert the Water Control Screw K into the Venturi Injector L lightly so as to leave the flow open 14 Place the Collection Cup D securely on top of the Reaction Column C as shown in Figur...

Page 9: ...he level should be adjusted so that the top of the foam is at the highest level without overflowing While this level will be very stable it is important to wait a few moments to allow for stabilizatio...

Page 10: ...cases the air intake can be regulated but it is an operation to be carried out after having acquired some experience with the skimmer An excessive closure of the air supply could damage the needle imp...

Page 11: ...h replacement needs will vary the Filter Sock M and Sponge I should be replaced every couple of months Secondary Pump Configuration optional O Secondary Pump P Venturi Extension Q O ring R Connecting...

Page 12: ...turi Injector L 4 Remove the cap from the Support Base A just under the Pump G by unscrewing the compression ring A 1 5 Insert the Venturi Extension P into the O ring Q and secure everything with the...

Page 13: ...nistered Some foods contain fatty acids and oils that can inhibit skimming Wait a few hours for the normal biological process to improve the conditions The aquarium may have reached a biological matur...

Page 14: ...14 Appendix Exploded View A B A B B A complete listing and diagram of replacements parts and codes is available at www aquavitro com...

Page 15: ...5 2 Recommended Water Height 14 20 cm 5 5 8 16 25 cm 6 10 16 25 cm 6 10 125 250 500 Liters US Gallons Liters US Gallons Liters US Gallons MaximumLoad extremely highSPSdensity 250 75 600 180 1200 250 A...

Page 16: ...aquavitro is a premium product line from Seachem Laboratories Inc Seachem Laboratories Inc 1000 Seachem Drive Madison GA 30650 www aquavitro com 888 SEACHEM...

Reviews: