IMPORTANT SAFETY INSTRUCTIONS

WARNING

 - To guard against injury, basic safety precautions should be observed, including the following:

A) READ AND FOLLOW ALL SAFETY INSTRUCTIONS

B) DANGER:

 To avoid possible electric shock, special care should be taken since water is employed in the 

use of aquarium equipment. For each of the following situations, do not attempt repairs by yourself; 

return the 

appliance to an authorized service facility for service or discard the appliance:

1) 

CAUTION: If the appliance falls into the water, DON’T reach for it! First unplug it and the retrieve it. If electrical 
components of the appliance get wet, unplug the appliance immediately. (Non-immersible equipment only)

2) 

If the appliance shows any sign of abnormal water leakage, immediately unplug it from the power source. (Non-

immersible equipment only)

3) 

Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not intended 
to be wet.

4)  Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or has been dropped or 

damaged in any manner.

5) 

To  avoid  the  possibility  of  the  appliance  plug  or  receptacle  getting  wet,  position 
aquarium stand and tank or the fountain to one side of a wall-mounted receptacle 
to prevent water from dripping onto the receptacle or plug. A “drip-loop” shown in 

the Figure A should be arranged by the user for each cord connecting an aquarium 

appliance to a receptacle. The “drip-loop” is the part of the cord below the level of the 
receptacle or the connector if an extension cord is used, to prevent water traveling 
along the cord and coming in contact with the receptacle.  If the plug or receptacle does 
get wet, DON’T unplug the cord. Disconnect the fuse or circuit breaker that supplies 
power to appliance. Then unplug and examine for presence of water in the receptacle.

 

C) 

Close supervision is necessary when any appliance is used by or near children.

D) 

To avoid injury, do not contact moving parts or hot parts such as heaters,  

reflectors, lamp bulbs and the like.

E) 

Always unplug an appliance from an outlet when not in use, before putting on or taking off parts and before 

cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.

F) 

Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the 
appliance manufacturer may cause an unsafe condition.

G) 

Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.

H) 

Make sure an appliance mounted on a tank is securely installed before operating it.

I) 

Read and observe all the important notices of the appliance.

J) 

If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or 
watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped 

over or pulled.

K) 

This appliance has a polarized plug (one blade is wider than other). As a safety feature, this plug will fit in a 
polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact 
a qualified electrician. Never use with an extension cord unless plug can be fully inserted. Do no attempt to defeat 

this safety feature.

EXCEPTION: This instruction may be omitted for an appliance that is not provided with a polarized attachment plug.

 

Summary of Contents for division 125

Page 1: ...division 125 250 500 User Manual...

Page 2: ...or de meest recente en of meertalige versie van deze gebruikershandleiding naar www aquavitro com downloads manuals division skimmers pdf DE Die aktuellste und oder mehrsprachigste Version dieses Benu...

Page 3: ...alongthecordandcomingincontactwiththereceptacle Iftheplugorreceptacledoes get wet DON T unplug the cord Disconnect the fuse or circuit breaker that supplies power to appliance Then unplug and examine...

Page 4: ...y children or mentally challenged individuals Appropriate adult supervision or persons responsible for personal safety is required 10 Do not disconnect from an electrical outlet by pulling the cord 11...

Page 5: ...tingfrommodification tamperingwithorattemptedrepairbyanyoneother than Seachem or its designee Transfer of the product to someone other than the original purchaser Subjecting the product to electrical...

Page 6: ...then extracted from the aquarium water the overall organic load of the aquarium is decreased Additionally the division series protein skimmer will increase oxygen content in the system increase oxida...

Page 7: ...eaction Column C onto the Support Base A 2 Apply the Locking Ring B around the connection point of the Reaction Column C to the Support Base A 3 Press the Venturi Injector L into the intake of the Pum...

Page 8: ...Silencer F 13 Insert the Water Control Screw K into the Venturi Injector L lightly so as to leave the flow open 14 Place the Collection Cup D securely on top of the Reaction Column C as shown in Figur...

Page 9: ...he level should be adjusted so that the top of the foam is at the highest level without overflowing While this level will be very stable it is important to wait a few moments to allow for stabilizatio...

Page 10: ...cases the air intake can be regulated but it is an operation to be carried out after having acquired some experience with the skimmer An excessive closure of the air supply could damage the needle imp...

Page 11: ...h replacement needs will vary the Filter Sock M and Sponge I should be replaced every couple of months Secondary Pump Configuration optional O Secondary Pump P Venturi Extension Q O ring R Connecting...

Page 12: ...turi Injector L 4 Remove the cap from the Support Base A just under the Pump G by unscrewing the compression ring A 1 5 Insert the Venturi Extension P into the O ring Q and secure everything with the...

Page 13: ...nistered Some foods contain fatty acids and oils that can inhibit skimming Wait a few hours for the normal biological process to improve the conditions The aquarium may have reached a biological matur...

Page 14: ...14 Appendix Exploded View A B A B B A complete listing and diagram of replacements parts and codes is available at www aquavitro com...

Page 15: ...5 2 Recommended Water Height 14 20 cm 5 5 8 16 25 cm 6 10 16 25 cm 6 10 125 250 500 Liters US Gallons Liters US Gallons Liters US Gallons MaximumLoad extremely highSPSdensity 250 75 600 180 1200 250 A...

Page 16: ...aquavitro is a premium product line from Seachem Laboratories Inc Seachem Laboratories Inc 1000 Seachem Drive Madison GA 30650 www aquavitro com 888 SEACHEM...

Reviews: