![Aquatronica ACQ450 Instruction Manual Download Page 9](http://html.mh-extra.com/html/aquatronica/acq450/acq450_instruction-manual_2961986009.webp)
9 - 14
IsACQ450- Rev. 300507-
Via dell’Industria, 0 - 405 Cavriago (RE) Italy Tel.: +39 05 494403
Fax: +39 05 494410 http:\\www.aquatronica.com E-mail: [email protected]
Dosing pump menu
Select pump (Fig.6)
Use this function to select the pump on which to acti-
vate the following operating modes:
- Manual Controls-
it lets you instantly set the quan-
tity of liquid set (Fig.8); proceed as follows to set this
function:
Main screen page
Main menu
Dosing Pumps
Select one of the dosing pump modules shown
Select pump
Select the dosing pump wanted
Manual controls
Enter the quantity of pro-
duct to dispense.
- Timer Programme
- it lets you carry out one or
more automatic dosing programmes using one of the
following modes:
-
Single -
it lets you dose the quantity of product
wanted (expressed in millilitres) within a period of
settable time and at a certain time the user himself
can define (Date and Hour).
Example 1
The example in Fig.9 shows pump programming
allowing to dose 50 ml of Iodine in a period of time of
one hour and 10 minutes starting from 14:55 of the
day 03/07/06.
-
Repetitive -
It lets you dose the quantity of product
wanted (expressed in millilitres) within a period of
settable time that will be repeated at regular intervals
and set by the user himself.
Example
The example in Fig.10 shows pump programming
allowing to dose 50 ml of Iodine in a period of time of
one hour and 10 minutes starting at 14:55 of the day
03/07/06 and repeated every 20 days.
(Fig. 6)
(Fig. 7)
(Fig. 8)
Select pump
01: Iodine
0: Calcium
03: Plankton
Iodine
Programme Timer
Calibration
Manual Controls
Manual controls
Millilitres 50
(Fig. 9)
Iodine
Millilitres: 50
Time: 1h10m
Hour: 14:55
Date: 03/07/06
Single
Pump Working: Yes
ENGLISH