Instruction Manual
Cod. ACQ450
3 DOSING PUMP
Page 1: ...Instruction Manual Cod ACQ450 3 DOSING PUMP ...
Page 2: ...5 Connecting the dosing pumps Page 6 Main Screen Page Page 7 Glossary of the icons Page 7 Main Menu Page 8 Name Change Page 8 Pump Selection Page 9 Manual Controls Page 9 Timer Programme Page 9 Calibration Page 10 Pump Working Yes Pump Working No Page 11 About Page 11 Certificate of Guarantee Page 11 Declaration of Conformity Page 12 Technical Data Page 13 TO VERIFY ON INTERNET THE PRESENCE OF EVE...
Page 3: ... 95 CE 2002 96 CE and 2003 108 CE concerning the reduction of the use of dangerous substances in electrical and electronic equi pment and waste disposal The symbol of the crossed waste bin on the equipment means that at the end of the equipment s useful life it must be collected separately from other waste To this end the user shall take the equipment at the end of its life to a centre that col le...
Page 4: ...ly original AQUATRONICA parts should be connected to the control unit or those it approves lf accessories are used that are not approved it could lead to damage fire electric shocks or injury to people The company is not liable for any damage to things or harm to people if the control unit is tampered with The product must be out of the reach of children to avoid the danger of electric shocks The ...
Page 5: ... Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com Pack Contents You will find 1 No 1 dosing pump 2 No 1 12V power supply with universal points 3 No 1 instruction manual 4 No 1 graduated container 5 No 1 BUS lead 1 3 5 4 ENGLISH 2 ...
Page 6: ...m Connecting the Dosing Pumps 1 Connector for connecting the dosing pumps to the supply point 12Volt 2 BUS sockets for connecting to the Aquarium controller and to other sensors 3 Jack for connecting accessories max 3 to the dosing pumps at a future date CONNECTING THE SENSORS TO THE PUMPS Pump A Pump B Pump C 3 2 1 Push button A Push button B Push button C ENGLISH ...
Page 7: ...e Day Month Year TIME 2 Icon display line 3 Pump module display line PD Dosing pump module 01 Number of pump modules con nected 4 Connected accessories display line Mon 21 08 06 15 05 Temperature 27 2 C 1 3 2 4 5 Glossary of the icons Icons that can be seen on the display Icon Description Pump in the manual dosing mode Pump not working It means a programme is active on the pump selected PD01 1 2 3...
Page 8: ...allowed Name Change Fig 4 This option allows to change the name of the dosing pump module or the name of each single pump of the module connected to the controller To change the name of the dosing pump module pro ceed as follows Select the Name Change menu with the keys and press Enter Select the letter to insert with the keys and use the keys to move around inside the word ex Fig 5 press Enter at...
Page 9: ...of product wanted expressed in millilitres within a period of settable time and at a certain time the user himself can define Date and Hour Example 1 The example in Fig 9 shows pump programming allowing to dose 50 ml of Iodine in a period of time of one hour and 10 minutes starting from 14 55 of the day 03 07 06 Repetitive It lets you dose the quantity of product wanted expressed in millilitres wi...
Page 10: ...l of liquid and completely free of air 3 Access the calibration screen page of the pump wanted 4 Set the amount of liquid for pump calibration The menu automatically displays as default a calibration quantity of 40 ml you can change this quantity if you want a different one see fig 12 Note For accurate pump calibration we suggest using as much liquid as possible 40 50 ml to minimise any parallax e...
Page 11: ...eople or damage to things caused by a malfunctioning product This guarantee is valid only if payments are in order Conditions The guarantee is valid for a period of 24 months from the date of purchase and only upon presentation of this certificate which must include the shop keeper s stamp the date of sale and the product s serial number together with the invoice or receipt issued by the shop keep...
Page 12: ... 4 F plugs I O ACQ013 CH 8 swiss plugs I O ACQ220 PC interface ACQ200 I O interface ACQ210 RX REDOX sonde interface ACQ210 PH PH sonde interface ACQ210 TL temperature and level sonde interface ACQ210 MS conducibility sonde interface ACQ210 D density sonde interface ACQ450 dosing pump 4 modules ARE IN COMPLIANCE WITH THE FOLLOWING PRODUCT SPECIFICATIONS FIELD Directive Description References Test R...
Page 13: ...Industria 20 42025 Cavriago RE Italy Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com Technical Data ENGLISH Dosing Pump Input Voltage 12VDC Current Used 250 mA Measurements L 162 x W 91 x H 53 mm ...
Page 14: ...Una divisione di A E B S r l v dell Industria 20 42025 Cavriago RE ITALY Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com ...