This option is used to create programs based on the
Conductivity value.
To set up a program, the following must be estab
-
lished:
- A
reference value
, defined as the Conductivity for the
tank, which the system will aim to maintain.
- A
∆
Max value
, defined as the tolerance that must
be observed with respect to values higher than the
reference value.
For example: If the reference is set to 900mS and the
∆ Max is 200mS, the system will be enabled at values
higher than 1100mS (see chart).
- A
∆
Min value
, defined as the tolerance that must
be observed with respect to values lower than the
reference value.
For example: If the reference is set to 900mS and the
∆ Min is 100mS, the system will be enabled at values
lower than 800mS (see chart).
To insert a program, proceed as follows:
Main screen
Main Menu
Conductivity
Programs.
• Select “
Insert
” using the
keys and press “
En-
ter
” (Fig. 5).
Insert
In this screen, the conductivity value to obtain can be
chosen and a minimum and maximum tolerance can
be set (Ex. Fig. 6).
To set this program, proceed as follows:
Main screen
Main menu
Conductivity
Programs
Insert.
•
Select with the reference conductivity value using
the
keys and set the desired value using the
keys.
•
Set the
“
∆
MIN”
and
“
∆
MAX”
tolerances; select the
desired parameter using the
keys and modify the
value using the
keys.
•
Select
“Sockets”
using the
keys to choose
how the outputs will function when the conductivity
level goes above or below the set values. Then press
“Enter”.
•
Select the output to be controlled using the
keys.
The selected output will blink on both lines.
The outputs on the upper line determine which devices
must be enabled/disabled when the conductivity goes
above the set maximum value (Ref. + ∆MAX); the out
-
puts on the upper line are set using the
key.
900
800
1100
Conductivity
Tempo
Ref.+
∆
Max
Key to symbols
Values for which the system is enabled
∆
Max=200mS
∆
Min=100mS
Ref.
Ref.-
∆
Min