IsACQ210NMSC-0 (ENG) Rev.250708-0

4 - 16

Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403  

Fax: +39 0522 494410 http:\\www.aquatronica.com E-mail: [email protected]

English

Thanks to the special shape of the box and fixing bracket, the interface can 

be fitted with others simply and very quickly, as seen below.

RACK FITTING 

Summary of Contents for ACQ210N-MS

Page 1: ...250708 0 1 16 Via dell Industria 20 42025 Cavriago RE Italy Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com Instruction Manual ACQ210N MS Low Range Conductivity Interface Density ...

Page 2: ... Table of Contents General Information Page 3 Pack contents Page 3 Connection Diagram Page 3 Connection to System Page 3 Displaying the read value Page 5 Conductivity Menu Page 5 Disconnect Page 11 Suggestions for an accurate reading Page 12 Waste diposal legislation Page 13 Warranty Page 14 Declaration of conformity Page 15 CHECK FOR ANY UPDATES ON THIS MANUAL ON THE WEBSITE ...

Page 3: ... the conductivity in aquariums Pack contents You will find One low conductivity probe connection interface One BUS cable for connecting the interface to the power unit One bag of accessories containing 1 fixing bracket 1 kit of cable diameter adaptor 1 guard 2 fixing screws English Connection to Aquarium Controller system 1 Connect the low conductivity probe s connector to the interface ACQ210N MS...

Page 4: ...avriago RE Italy Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com English Thanks to the special shape of the box and fixing bracket the interface can be fitted with others simply and very quickly as seen below RACK FITTING ...

Page 5: ...ce the values read by the probe will be displayed on the main screen If several sensors were connected their values can be checked in order by pressing the and keys Conductivity Menu Once the probe and interface are connected the Con ductivity menu will appear in the Main Menu where all of its settings can be programmed All sensor menus have the same structure in order to make them more intuitive ...

Page 6: ... values lower than 800mS see chart To insert a program proceed as follows Main screen Main Menu Conductivity Programs Select Insert using the keys and press En ter Fig 5 Insert In this screen the conductivity value to obtain can be chosen and a minimum and maximum tolerance can be set Ex Fig 6 To set this program proceed as follows Main screen Main menu Conductivity Programs Insert Select with the...

Page 7: ...d sockets have been set press Enter to return to the previous menu Ex Fig 6 The Confirm field is automatically selected by press ing Enter the inserted program is saved If different conductivity values are desired based on the time of day these can be set graphically To set this function proceed as follows Main screen Main menu Conductivity Programs Insert Using the keys select the conductivity re...

Page 8: ...Fig 10 Select Modify using the keys to modify the program or change the desired parameters Then press Enter to confirm the change Select Delete Program using the keys to delete the program The delete screen will appear Fig 11 Press Enter to delete or Esc to cancel Delete All Fig 12 In this menu all of the programs inserted in the menu can be deleted at one time To use this function proceed as foll...

Page 9: ...y level goes below or above the Less than or Greater than values Ex Fig 14 If the conductivity value exceeds these limits the conductivity value on the main screen will blink if the alarm is set to No Sound If the alarm is set to Sound the value will blink an acoustic signal will sound and the icon will appear on the main screen To program this function proceed as follows Main screen Main menu Con...

Page 10: ...e must be rinsed using tap water dried carefully and inserted in the Aquatronica conductivity solution In order to correctly calibrate the sensor proceed as follows Main screen Main menu Conductivity Calibrate Sensor New 1 Select the function New by using the keys then press Enter Fig 15 2 Using the keys set the value of the standard solution next to Calib Value Fig 17 3 Wait 10 minutes in order t...

Page 11: ...uctivity interface is reconnected the con trol unit will automatically begin displaying the read value again To definitively eliminate the conductivity sensor from the system after disconnecting it proceed as follows Main screen Main menu Conductivity Disconnect The Data Record and Calibrate Sensor functions disappear from the Conductivity menu Fig 20 and the Disconnect function appears Select thi...

Page 12: ...he instrument approximately every month as indicated to previ ous pages to correct any reading imperfections due to probe wear Never use calibration solutions that have been left open or have expired Before calibration rinse the probe with tap water and dry it carefully Replace the probe after a period of approximately 15 18 months Do not install the interface in direct contact with wet or damp pa...

Page 13: ...tro technical waste or he she must turn over the used product to the retailer when buying a new equivalent product on a one to one basis Separate waste collection allows used equipment to be recycled treated and disposed of without negative consequences for the environment and health and it allows the materials in the equipment to be recycled Illegal dumping of the product by the user entails the ...

Page 14: ... and the product s serial number accompanied by the invoice or receipt issued by the retailer indicating the serial numbers of the installed products If this information is missing the final customer will receive warranty coverage valid for 24 months starting from the date printed on the back of the product AQUATRONICA can refuse to recognize the warranty if this information is incomplete or has b...

Page 15: ...sACQ210NMSC 0 ENG Rev 250708 0 15 16 Via dell Industria 20 42025 Cavriago RE Italy Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica com Declaration of Conformity ...

Page 16: ...A E B Srl Division Via dell Industria 20 42025 Cavriago RE Italy Tel 39 0522 494403 Fax 39 0522 494410 http www aquatronica com E mail service aquatronica it A E B Srl Division ...