background image

6

Hazardous pressure.
Can cause severe 
injury or major 
property damage 
from tank blow up

Release all pressure
and read instructions
before working on filter.

INITIAL START-UP

Be sure pump is OFF before starting procedure.

Do not operate these filters at more than 50 PSI (345 kPa) under any

circumstances!

1. Securely lock Safe-Lok™ ring in place by rotating ring CLOCKWISE until it

“clicks” past the safety latch (see Figure 3). Stop turning as soon as the ring
clicks past the latch. The ring may feel slightly loose, but it will tighten up
when pump is on and filter is under pressure.

2. Fill trap on pump with water.
3. Open air release valve on top of filter.
4. Open isolation valves.
5. Start pump to purge air from system.
6. When steady stream of water comes from air release valve, close the

valve.

NOTICE:

Leaking around the Safe-Lok™ ring may indicate that the ring is

not fully locked. In this case, proceed as follows:

A. Stop the pump, close the isolation valves, and open the air release valve

to release any pressure within the filter. 

B. Remove the drain plug and drain all water from the filter.
C. Push down on the top of the filter to fully seat the upper tank shell.
D. Rotate the Safe-Lok™ clockwise until it locks behind the safety latch

(see Figure 3). 

E. If the ring was already locked, remove it and the upper tank shell.

Inspect and clean the O-ring and all sealing surfaces. Re-lubricate the
O-ring.

NOTICE:

Lubricate O-ring only with the silicone grease provided or equiva-

lent, as other lubricants may cause the ring to swell.  DO NOT lubricate 
Safe-Lok™ ring or threads on lower tank shell as this may collect grit and
make removal difficult.
After filter is operating, record filter pressure gauge reading in owner's manual
for future use.

NOTICE: 

When installed on a new pool, after approximately 48 hours of op-

eration disassemble filter and clean out plaster dust , construction debris, etc.
(see “Module Cleaning Procedure", Pages 7 and 8).

FILTER DISASSEMBLY/
ASSEMBLY PROCEDURE

Hazardous pressure. Before disassembling filter:

1. STOP PUMP.

2. CLOSE isolation valves.

3. OPEN air release valve and drain fitting.

4. WAIT until all pressure is released and water drained from filter tank and

system before loosening Safe-Lok™ Ring.

Disassembly:

1. Stop the pump.
2. Close isolation valves to prevent flooding. 
3. Open air release valve on top of filter tank to release all pressure from inside

of tank.

Depress Safety Latch
to unscrew Posi-Lok™

RELEASE

RELEASE

Figure 4 – Depress safety latch to
unscrew Safe-Lok™ Ring.

2149 1195

Latch

Tab

Figure 3 – Rotate Safe-Lok™
Ring until tab locks behind the
safety latch.

Summary of Contents for AT84100

Page 1: ...752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 Union City TN Delavan WI Mississauga Ont Murrieta CA 2003 Printed in U S A AT338 Rev 2 3 03 This manual should b...

Page 2: ...urce of pressurized water 2 Use equipment only in a pool or spa installation 3 Trapped air in system can cause explosion BE SURE all air is out of system be fore operating or testing equipment Before...

Page 3: ...order Replace a damaged gauge immediately Cleaning interval is based on pressure rise not on length of time filter is op erated Different water conditions will have different normal cleaning inter va...

Page 4: ...120 454 140 529 160 606 Flow in Gallons Per Minute LPM 20 138 150 568 SPECIFICATIONS FIGURE 1A Dimensions in inches mm Table 1 Filter Specifications Model No AT84100 AT84150 Filter Area sq ft m2 100 9...

Page 5: ...he most convenient piping run After you have piped the inlet and drain apply the inlet decal to the port to which you have run the inlet piping For ease of maintenance use AquaTools union couplings to...

Page 6: ...e until it locks behind the safety latch see Figure 3 E If the ring was already locked remove it and the upper tank shell Inspect and clean the O ring and all sealing surfaces Re lubricate the O ring...

Page 7: ...the bottom of the filter cartridge over the tank outlet port Push down firmly to seal 3 Ensure that the air bleed assembly on top of the module is clean and prop erly mounted NOTICE Lubricate O ring...

Page 8: ...ns of this manual Special Cleaning Instructions Use this procedure to clean scale or oils which are not removed by hosing down module Be sure to dispose of spent chemicals according to all applica ble...

Page 9: ...o explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping NOTICE Protect the filter from freezing...

Page 10: ...d 8 B Water is chemically out of balance consult pool professional C Excessive air in filter Vent air from tank and check for pump suction pipe leaks Clean air bleed filter in module assembly with a h...

Page 11: ...ring 1 35505 1424 9 2 x 1 1 2 Pipe reducer 2 U78 820P 10 Pressure gauge 1 15060 0000T 11 Air bleed assembly 1 24800 0121 12 Filter module AT84100 1 27002 0100S 12 Filter module AT84150 1 27002 0150S 1...

Page 12: ...t to negligence misappli cation improper installation or maintenance or other cir cumstances which are not in AquaTools direct control Full warranty coverage is in effect for one year after instal lat...

Reviews: