AquaTools AT84100 Owner'S Manual Download Page 2

READ AND FOLLOW SAFETY 
INSTRUCTIONS!

This is the safety alert symbol. When you see this symbol on your filter or in

this manual, look for one of the following signal words and be alert to the

potential for personal injury.

warns about hazards that 

will

cause death, serious personal injury, or

major property damage if ignored.

warns about hazards that 

can

cause death, serious personal injury, or

major property damage if ignored.

warns about hazards that 

will

or 

can

cause minor personal injury or

property damage if ignored.

NOTICE 

indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on equipment.

Keep safety labels in good condition; replace if missing or damaged.

Incorrectly installed or tested equipment may fail, causing
severe injury or property damage. 

Read and follow instructions in

owner's manual when installing and operating equipment. Have a
trained pool professional perform all pressure tests.

1. Do not connect system to a city water system or other external source of 

pressurized water.

2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE all air is out of system be-

fore operating or testing equipment.

Before pressure testing, make the following safety checks:

• Check all clamps, bolts, lids, lock rings and system accessories before testing.
• Release all air in system before testing.
• Tighten AquaTools™ pump trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing.
• Water pressure for test must be less than 25 PSI (172 kPa).
• Water Temperature for test must be less than 100

o

F. (38

o

C).

• Limit test to 24 hours. After test, visually check system to be sure it is ready for

operation. Remove pump trap lid and retighten hand tight only.

NOTICE:

These parameters apply to AquaTools™ equipment only. For 

non-AquaTools™ equipment, consult equipment manufacturer.

2

Table of Contents

Safety Instructions ..............................................................................................2

General Information ...........................................................................................3

Specifications .....................................................................................................4

Installation .........................................................................................................5

Initial Startup......................................................................................................6

Filter Disassembly / Assembly .........................................................................6-7

Module Cleaning Procedure............................................................................7-8

Special Cleaning Instruction............................................................................8

System Inspection/Winterizing............................................................................9

Troubleshooting Guide .....................................................................................10

Repair Parts List ................................................................................................11

Warranty ..........................................................................................................12

WARNING

Hazardous Pressure!

Can cause tank 
explosion.

Don not connect filter to
compressed air under any
circumstances.

Summary of Contents for AT84100

Page 1: ...752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 Union City TN Delavan WI Mississauga Ont Murrieta CA 2003 Printed in U S A AT338 Rev 2 3 03 This manual should b...

Page 2: ...urce of pressurized water 2 Use equipment only in a pool or spa installation 3 Trapped air in system can cause explosion BE SURE all air is out of system be fore operating or testing equipment Before...

Page 3: ...order Replace a damaged gauge immediately Cleaning interval is based on pressure rise not on length of time filter is op erated Different water conditions will have different normal cleaning inter va...

Page 4: ...120 454 140 529 160 606 Flow in Gallons Per Minute LPM 20 138 150 568 SPECIFICATIONS FIGURE 1A Dimensions in inches mm Table 1 Filter Specifications Model No AT84100 AT84150 Filter Area sq ft m2 100 9...

Page 5: ...he most convenient piping run After you have piped the inlet and drain apply the inlet decal to the port to which you have run the inlet piping For ease of maintenance use AquaTools union couplings to...

Page 6: ...e until it locks behind the safety latch see Figure 3 E If the ring was already locked remove it and the upper tank shell Inspect and clean the O ring and all sealing surfaces Re lubricate the O ring...

Page 7: ...the bottom of the filter cartridge over the tank outlet port Push down firmly to seal 3 Ensure that the air bleed assembly on top of the module is clean and prop erly mounted NOTICE Lubricate O ring...

Page 8: ...ns of this manual Special Cleaning Instructions Use this procedure to clean scale or oils which are not removed by hosing down module Be sure to dispose of spent chemicals according to all applica ble...

Page 9: ...o explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping NOTICE Protect the filter from freezing...

Page 10: ...d 8 B Water is chemically out of balance consult pool professional C Excessive air in filter Vent air from tank and check for pump suction pipe leaks Clean air bleed filter in module assembly with a h...

Page 11: ...ring 1 35505 1424 9 2 x 1 1 2 Pipe reducer 2 U78 820P 10 Pressure gauge 1 15060 0000T 11 Air bleed assembly 1 24800 0121 12 Filter module AT84100 1 27002 0100S 12 Filter module AT84150 1 27002 0150S 1...

Page 12: ...t to negligence misappli cation improper installation or maintenance or other cir cumstances which are not in AquaTools direct control Full warranty coverage is in effect for one year after instal lat...

Reviews: