background image

6

w w w . a q u a t i c l i f e . c o m

RO Daddy

 Instruction Guide

MEMBRANE REPLACEMENT (CONT.)

  When the plug is removed, the membrane

 

located inside the housing is visible. Pull the

 

membrane out of the housing and replace

 

with the new membrane.

  Reinstall the membrane housing plug. 

 

  Install the membrane clamps, secure the

 

membrane housing strap and replace the

 

U-Shaped connection between the filter

 

canisters and the membrane housing. 

CARTRIDGE REPLACEMENT - MAINTENANCE

The cartridges should be monitored and logged for best 
performance.  It is extremely important that you do not run 
chlorinated water though the membrane as it will damage the 
membrane and cause the filtered water quality to deteriorate.  

 

Micron Cartridge

 – This mechanical filter removes

 

particulates only and will not reduce the chlorine levels

 

in the supply water. The cartridge should be changed

 

when it either visually looks dirty or if water

 

production decreases.

 

Granular Activated Carbon (GAC) Cartridge

 –

 

This chemical filter removes approximately 1ppm of

 

chlorine from the supply water for approximately

 

15,000 total gallons. If the supply water has 2 ppm

 

of chlorine, it will filter up to 7,500 gallons total.

 

Solid Carbon Block Cartridge

 – This second stage

 

chemical filter is comprised of compressed carbon

 

ground into small particles and held together with

 

a fine mesh. The small size carbon effectively

 

removes approximately 1ppm of chlorine up to

 

15,000 total gallons. 

Item # 

Description 

UPC

330323 

Cartridge 20" x 4.5"  

810957013233

 

1 Micron Pre-filter

330324 

Cartridge 20" x 4.5" 

810957013240

 

Solid Carbon Block Pre-filter 

330325 

Cartridge 20" x 4.5" GAC 

810957013257

330327 

Membrane TFC 1000 GPD 

810957013271

NOTE:

 Observe the water flow direction for 

the membrane. The water should flow from 
the left side of the membrane housing to the 
right side of the housing. The membrane 
may indicate the water flow and should have
a gasket or O-ring around the left side of the 
membrane. This gasket seals the membrane 
inside the housing and prevents water from 
bypassing the membrane and into the waste 
water stream. 

NOTE:

 The initial water production

from the RO unit should be discarded.
The membrane is shipped with a 
preservative that should be flushed out
prior to use.  We recommend operating
the unit for one hour prior to using the 
filtered water production.

TIP:

 Use a sealing lubricant on the O-rings 

to help prevent leaks and aid with future 
removal of the membrane housing plug. 

WARNING:

The volume of water that the cartridge will filter must be 
calculated to include both the filtered water volume and 
the waste water volumes. If you produce a 1,000 
gallons of filtered water and use the included flow 
restrictor, you produced 1,800 gallons of waste water 
for a combined total of 2,800 gallons of filtered
through the cartridges. 

It is a good idea to calculate how often you should 
change the cartridges based on water production 
usage. It is much more cost effective to replace the 
cartridges compared to a new membrane.

Summary of Contents for RO Daddy

Page 1: ...r customer support department at 1 888 548 3480 Monday Friday 8 00 AM 4 00 PM Pacific Time or by e mail at customersupport aquaticlife com PARTS LIST Filter Housing Filter Cartridges Micron GAC Granul...

Page 2: ...ould be located in the right side canister this cartridge is the all white fiber cartridge MIDDLE GAC cartridge should be located in the center canister this cartridge is made with a solid plastic hou...

Page 3: ...he clip is removed insert the tubing into the elbow You MUST make sure the tubing is pressed into the fitting far enough to secure the tube You should feel a Double Push into the fitting this is a res...

Page 4: ...multiple connection options Wrap the male threaded connection with plumber s Teflon tape prior to inserting into the threaded female connection on the side of the canister housing Rotate the connecti...

Page 5: ...T need to be completely removed Remove the U shaped connection between the filter canisters and the membrane housing Refer to the membrane connection section referenced previously This will allow the...

Page 6: ...1ppm of chlorine up to 15 000 total gallons Item Description UPC 330323 Cartridge 20 x 4 5 810957013233 1 Micron Pre filter 330324 Cartridge 20 x 4 5 810957013240 Solid Carbon Block Pre filter 330325...

Page 7: ...the product THIS CONSTITUTES AQUATIC LIFE S ENTIRE WARRANTY AND AQUATIC LIFE MAKES NO OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THE PRODUCT AQUATIC LIFE LLC SPECIFICALLY DISCLAIMS A...