background image

PRE-INSTALLATION

1:

  D

D

DO

O

OW

W

WN

N

NTTTO

O

OW

W

WN

N

N

TECHNICAL SPECIFICATIONS

PLATFORM

ok

ok

Freestanding

                                                                         

Emergency Drain

The manufacturer suggests a minimum load

of 54lbs/ft

2  

Maximum water content

Maximum water content

137 Gallons

Weight with water

Weight with water

1631 lbs

Weight when empty

Weight when empty

485 lbs

Voltage

Voltage

220V

220V

Amperes

Amperes

Whirlpool pump motor

Whirlpool pump motor

2x2 HP

2x2 HP

Recirculation motor

Recirculation motor

1/15 HP

1/15 HP

Heating

Heating

4kW

4kW

Operating temperature

Operating temperature

2

Downtown Built-in

Recessed

30A Breaker

30A Breaker

-23˚F~+113˚F

Summary of Contents for Downtown Spa

Page 1: ...Downtown Spa Pre Installation Manual by...

Page 2: ...ximum water content 137 Gallons Weight with water Weight with water 1631 lbs Weight when empty Weight when empty 485 lbs Voltage Voltage 220V 220V Amperes Amperes Whirlpool pump motor Whirlpool pump m...

Page 3: ...An incorrect pre installation could cause structural damage to the spa and void the warranty TEMPORARY POSITIONING The installation of the hot tub should be done immediately upon receipt In any case o...

Page 4: ...ation of the installation site 2 Preparation of the installation site 3 Preparation of the plumbing 4 Preparation of the electrical system 4 IN 40 Electrical connection Drain Water supply Technical in...

Page 5: ...sistent with local regulations A sunny area with increased exposure during the morning ensures greater well being for users Consider the geological composition of the soil on which the supporting plat...

Page 6: ...ompartment Technical compartment for maintenance of operational components plan for 20 inches on all sides of the minipool CONCRETE SLAB h 10 cm minimum See the technical drawing RECESSED INSTALLATION...

Page 7: ...vents to ensure proper ventilation of the technical compartment BUILT IN INSTALLATIONS D C B A Inspection compartment details Controls Installations side NB Make sure the weight is supported on the b...

Page 8: ...by Downtown Spa DOWNTOWN SPA FREESTANDING Built in 8 Base cutout for drainage electrical feed and water supply if applicable...

Page 9: ...ur US Canadian Spa series bathtubs ship with 60Hz pumps while our International models ship with 50Hz pumps WARNING Risk of electrical shock Make sure the power has been disconnected before performing...

Page 10: ...Function Form Fashion 14 aquaticausa com aquaticabath ca aquaticabath co uk aquaticabath eu...