background image

Aquatic Fitness System - Owner’s Manual

12

 Settings Menu 

Page 1 

MAIN > 

Page 2 

MAIN >   > 

Filter Cycle Menu 

Pressing the filter cycle button brings up the filter 
cycle menu, which adjusts how long and how often 
the spa’s filter cycle runs. 

Start Time 

To adjust the filter cycle’s start time, use the left 
and right arrows on the 5-Key Context Keypad to 
select whether to modify hours or minutes.  Use 
the up and down arrows on the 5-Key Context 
Keypad to select the start time. Press Accept to 
save the changes. 

Frequency 

Use the up and down arrows on the 5-Key Context 
Keypad to adjust the number of filter cycles per 
day.   Press Accept to save the changes. 

Duration 

Use the up and down arrows on the 5-Key Context 
Keypad to adjust how many minutes each filter 
cycle will last. Press Accept to save the changes.

Runtime 

Pressing the Runtime button brings up the Runtime 
Setting menu. This menu adjusts how long the jets 
and waterfall run.   

Adjusting Runtime 

Push the Jets or Waterfall button to bring up that 
item’s Runtime screen.  On this screen, use the up 
and down arrows on the 5-Key Context Keypad to 
select how many minutes each cycle will last. 
Press Accept to save the changes.   

Summary of Contents for AquaFit 16

Page 1: ...i...

Page 2: ...itnessSystems com Registering your product establishes your warranty protects your product and helps us develop new and better products My Aquatic Fitness System AquaFit 16 AquaPro 19 AquaFit 19DT Gal...

Page 3: ...TETHER 15 USING THE SWIM KICK BAR 16 USING THE SWIM JETS 16 OPTIONAL HYDROSPORT ROWING SYSTEM 17 INSTALLING THE ROWING SYSTEM 17 ROWING FOR THE FIRST TIME 18 CONNECTING THE HYDROSPORT BODY BELT 19 CON...

Page 4: ...se of this equipment requires the user to always follow safety precautions including x Risk of Accidental Drowning Exercise extreme caution to prevent unsupervised children going near the Aquatic Fitn...

Page 5: ...System Long exposures at high temperatures can cause high body temperature hyperthermia see pg 3 Enter and exit the Aquatic Fitness System slowly Wet surfaces can be very slippery x Proper chemical m...

Page 6: ...ess System or hot tub x AVERTISSEMENT LES FEMMES ENCEINTES QUE LEUR GROSSESSE SOIT CONFIRM E OU NON DEVRAIENT CONSULTER UN M DECIN AVANT D UTILISER UNE CUVE DE RELAXATION x Water temperature in excess...

Page 7: ...read all operating instructions x DO read understand and follow all Safety Danger and Warning instructions before use x DO test water temperature with your hand before entering x DO keep the cover do...

Page 8: ...ning off the GFCI check for a blank control panel screen which means the power is off To turn power back on move the switch to the ON position If you have questions about the location or operation of...

Page 9: ...the valve perpendicular to the pipe to close the hose bibs 9 Place a garden hose in the empty filter canister to fill the system Fill the system until the water level reaches the center of the tile l...

Page 10: ...r temperature exceeds 104q F 40q C the display will show the actual temperature Never get in water if the temperature exceeds 104q F 40q C 12 After the jets are functioning properly replace the filter...

Page 11: ...ht corner of the screen The left and right arrows allow navigation through the menu structure The Temperature menu and the Settings menu are the two main menus on the control panel The Temperature men...

Page 12: ...re Screen The Temperature screen displays the current swim spa temperature and sets the desired swim spa temperature Clock Screen The Clock screen displays the current time of day Runtime Screen The R...

Page 13: ...alue will be replaced by Summer Light Operation Your swim spa is equipped with a Dynamic L E D Light The light has 2 modes Color Change which cycles through all colors and Color Select which allows se...

Page 14: ...filter cycle the indicator light for Jets 1 glows If you manually press JETS 1 during a filter cycle that particular filter cycle disables to give you control of the jet pump Pumps 2 and 3 provide hig...

Page 15: ...ave the changes Frequency Use the up and down arrows on the 5 Key Context Keypad to adjust the number of filter cycles per day Press Accept to save the changes Duration Use the up and down arrows on t...

Page 16: ...eft and right arrows on the 5 Key Context Keypad to adjust the contrast of the display screen Press Accept to save the changes Language Use the up and down arrows on the 5 Key Context Keypad to select...

Page 17: ...nance button to bring up the Maintenance Reminder adjustment screen Use the up and down arrows on the 5 Key Context Keypad to choose if the spa will display maintenance reminders Press Accept to save...

Page 18: ...ist using a quick release buckle and adjusts from the back Swim Tether Mounts are located at either end of the AFS see picture at left Place the pole in the mount strap on the adjustable belt and adju...

Page 19: ...rs on the side front and bottom of the spa to properly position yourself in the swim lane You can also use the swim jets for resistance to while walking or jogging in place Using the Diverter Valve Th...

Page 20: ...he OptiMounts identified by 2 in the 1 2 3 picture A good guide for measuring the correct installation of the rowers is to ensure that you first screw the rower into the OptiMount until it is almost s...

Page 21: ...wers are designed with four separate connection rings allowing you the option of multiple Tensor Cords that offer a wide range of exercises A variety of OptiMount locations allow for installation of a...

Page 22: ...nkle and adjust the cuff to fit you comfortably Be sure it fits firmly If the cuff comes loose during your exercise you or your partner could be injured Snap a HydroSport tensor cord into the D rings...

Page 23: ...Butterfly Top screw through the hole in the end of the bar and screw it into the OptiMount Repeat for the other end of the bar If two bars connect to the same OptiMount line up the holes on the bars i...

Page 24: ...ne up with the securing tabs Pull the basket assembly straight up to remove it Remove the filter below the basket by twisting it 1 4 turn counterclockwise to its stop Lift the filter out of its canist...

Page 25: ...erracina Oak cabinet become stained use the 3M Graffiti Remover System to remove the stain Special Cold Weather Instructions Dimension One Spas design allows for year round use The insulation allows f...

Page 26: ...all the fittings that loosened are re tightened x Replace all jet fittings pump drain plugs hose bib drains and bleeder valves x Fill the system with water in the normal way x Turn the power back on x...

Page 27: ...Turn down the set temperature on the control panel Display reads OVERHEAT 3 High limit or sensor problem 3 Call your dealer for service Electrical System Symptom Problem Corrective Action Will not tur...

Page 28: ...the Selector Valve to the appropriate position 3 Dirty Filter 3 Clean Filter 4 Air lock 4 Loosen pump union to allow air to bleed No Jet Action or action is poor 5 Gate valve closed 5 Open gate valve...

Page 29: ...Aquatic Fitness System Owner s Manual 26...

Page 30: ...a side 240V 3 wire ground 50A 6 AWG Contact your local dealer for any questions related to electrical requirements or gas heater conversion procedure International AFS Electrical Requirements Model Po...