AquaticAccess.com
1921 Production Drive, Louisville, Kentucky 40299-2110 USA
800.325.5438 502.425.5817 Fax: 502.425.9607
Page 1: ...Aquatic Access Inc Pool Lift Model IGMT Installation Guide Instruction Manual AquaticAccess com 1921 Production Drive Louisville Kentucky 40299 2110 USA 800 325 5438 502 425 5817 Fax 502 425 9607...
Page 2: ......
Page 3: ...Decks Alternative Installations Assembly of Lift Water Connection Attach Seat Operation of Lift Service and Maintenance Routine Inspection Disassembly of Lift Determining the Cause of a Leak Cleaning...
Page 4: ......
Page 5: ...tion for the lift Using a 4 carbide core drill provided by the customer drill a hole in the concrete decking and clear to a depth of 8 Fill the hole around the socket with a good grade of hydraulic ce...
Page 6: ...socket plate above and insert bolts Place washers and nuts on bolt and tighten securely For installations where there is a concrete deck with a void beneath 1 2 anchor bolts are used to secure the anc...
Page 7: ...bly any accessories Carton 3 The mast is contained in the third package After you have installed the socket and allowed the cement to cure overnight insert the mast into the socket and check that it r...
Page 8: ...t Although 55 65 PSI is required to lift the rated load less weight can be lifted wiht lower pressures In low pressure situations a pump can be added to boost pressure If a pump is used do not use wat...
Page 9: ...le aligned with the T handle lock in the desired stationary position Once the person is seated rotate the seat until it is over the water and lower the seat slowly by opening the valve a little at a t...
Page 10: ...end the piston rod completely This will expel most of the water from inside cylinder 4 Pull the piston rod back into cylinder by hand Rotate the cylinder back over the deck and let the piston rod rest...
Page 11: ...hrough the top of the cylinder 9 Place the piston rod assembly on a CLEAN surface as dirt and debris will adversely affect the lift s performance Handle the piston rod carefully Any scratches on the p...
Page 12: ...ll or simply by age or wear Replacement seals are always available from Aquatic Access CLEANING OF THE INSIDE OF THE CYLINDER To clean the inside of the cylinder spray the inside with an all purpose c...
Page 13: ...g threads 9 Once the piston rod assembly is installed rotate it so the seat bracket holes at the bot tom of the piston are parallel to the 1 2 top mounting bolt holes at the top of the cylinder 10 Sli...
Page 14: ...quaticAccess com Remember to send in your warranty card to Aquatic Access 1921 Production Drive Louisville KY 40299 2110 If it becomes necessary to replace any part in your unit we need to know its se...
Page 15: ...is to be left unused for eight hours or longer Always run the seat up and down through several cycles after turning the water supply on This bleeds air out of the cylinder which could cause unexpected...
Page 16: ...g on or around the lift 6 Do not jump or dive from lift 7 Turn water supply OFF and secure lift with push pin when the lift is to be left unused for eight hours or longer 8 Always run the seat up and...
Page 17: ...er squirts out of top of cylinder Large amounts of water are getting past the seal Often this corrects itself If not clean or replace the seal White grey or brown chalky deposits on out side surfaces...