background image

 

AquaShield

TM

 Bio-Filter

TM

 

Overview 

 
 

The highest priority of AquaShield

TM

, Inc. (AquaShield™) is to protect waterways 

by  providing  stormwater  treatment  solutions  to  businesses  across  the  world. 
These  solutions  have  a  reliable  foundation  based  on  over  20  years  of  water 

treatment experience. Local regulators, engineers, and contractors have praised 
the AquaShield

TM

 systems for their simple design and ease of installation. All the 

systems  are  fabricated  from  lightweight,  durable  materials,  and  contractors 

prefer the quick and simple installation of our structures that saves them money.  

The  AquaShield

TM

  line  of  patented  stormwater  treatment  products  provide  high 

levels  of  stormwater  treatment.  AquaShield

TM

  manufactures  the  following 

integrated product solutions: 

 

Aqua-Swirl

®

 Stormwater Treatment System 

 

Aqua-Filter

TM

 Stormwater Filtration System 

 

Aqua-Guardian

TM

 Catch Basin Insert 

 

AquaShield

TM

 Bio-Filter

TM

 Stormwater Biofiltration System 

The 

Bio-Filter

TM

  Stormwater  Biofiltration  System

  is  capable  of  gross 

contaminant removal, coarse- and fine-grained sediment removal, oil removal, as 

well as the removal of heavy metals and phosphorus.  

This  Inspection  and  Maintenance  Manual  provides  important  information  for 

continued effective operation of the AquaShield

TM

 Bio-Filter

TM

 system. 

The  Bio-Filter

TM

 

Stormwater  Biofiltration  System

 

is  a  modular  “tree  box”  design 

that provides an innovative and sustainable green infrastructure solution to meet 

the  growing  challenges  of  Low  Impact  Development  (LID)  practices.  The  Bio-

Filter

TM

 is a water quality treatment device capable of removing coarse and fine 

sediment, trash and debris, heavy metals bound to particulate matter, and oil by 

utilizing  elements  of pretreatment  and biofiltration.  Biofiltration is  accomplished 
by a proprietary engineered soil biomedia as well as uptake by the selected tree.  

 

The  Bio-Filter

TM

  provides  advanced  pretreatment  for  rainwater  collection 

structures,  or  can  be  used  as  a  standalone  device  for  discharges  to  sensitive 

receiving waters. Each system is custom engineered for site-specific needs using 
proven  lightweight  and  durable  Polymer  Coated  Steel  (PCS).  The  system 

operates  under  gravitational  and  hydrodynamic  forces  with  no  moving  parts 

which simplifies the treatment process. The standard Bio-Filter

TM

 system utilizes 

 

Summary of Contents for Bio-Filter

Page 1: ...Biofiltration System Inspection and Maintenance Manual March 2017 AquaShield TM Inc 2733 Kanasita Drive Suite 111 Chattanooga TN 37343 Phone 423 870 8888 Fax 423 826 2112 Email info aquashieldinc com...

Page 2: ...le of Contents AquaShieldTM Bio FilterTM Overview Bio FilterTM Operation Bio FilterTM Inspection Maintenance Appendix 2733 Kanasita Drive Suite 111 Chattanooga Tennessee 37343 Phone 423 870 8888 Fax 4...

Page 3: ...ned sediment removal oil removal as well as the removal of heavy metals and phosphorus This Inspection and Maintenance Manual provides important information for continued effective operation of the Aq...

Page 4: ...lation After the Bio Filter is installed and before media installation ensure that the filtration chamber is free from debris and that the perforated underdrain pipe is connected and in place refer to...

Page 5: ...ion Chamber 4 Outlet Chamber 5 Internal Bypass These system components are identified in Figure 1 The five steps of Bio FilterTM treatment are described in the sections below Step 1 Inlet and Trash Sh...

Page 6: ...chamber Any floatables and oil will be retained by the arched baffle positioned on the outlet side of the chamber Water exits the Pretreatment Chamber underneath the arched baffle and through a horiz...

Page 7: ...he need for any external bypass structures Internal bypass occurs when the head level rises within the unit such that flows in excess of the water quality treatment flow will spill across the overflow...

Page 8: ...releases of contaminants at the facility or location and 3 the nature of the area being drained In order to ensure that our systems are being properly maintained AquaShield offers a maintenance soluti...

Page 9: ...f significantly free of accumulated materials to ensure proper operation of the Bio FilterTM unit Materials can be removed by the use of a vacuum truck while performing maintenance of the other Bio Fi...

Page 10: ...snake line can be inserted through the Internal Bypass opening and down to the opening of the Underdrain Pipe Any sediment in the pipe can be vacuumed out accordingly Outlet Chamber The Outlet Chamber...

Page 11: ...APPENDIX Inspection and Maintenance Data Sheets...

Page 12: ...ing if value in step 4 is six 6 inches or more 6 Remove accumulated sediment and water from Pretreatment Chamber by Vacuum system 1 Remove tree grate to expose tree trunk 3 inch mulch layer and top fe...

Page 13: ...o remove sediments oils and other floatable pollutants with a vactor trailer The spent biomedia and sediment generally do not require any special treatment or handling for disposal The filter media ca...

Page 14: ...s to Be Taken Time Frame NOTES 1 Attach site plan showing Bio Filter location 2 Attach detail drawing showing Bio Filter dimensions and model number 3 If an External Bypass structure is used attach de...

Page 15: ...tain As Needed Second and Subsequent Years Post Construction Month During Construction Month First Year Post Construction Month Date Construction Started AquaShield Bio Filter TABULAR MAINTENANCE SCHE...