The IonGen
™
is warranted against
defective materials and workman-
ship for a period of 12 months from
the date of purchase by the user.
Contact the installer or place of
purchase if the IonGen
™
should fail
within the warranty period. Warranty does not include deteriorated
probe. Warranty shall be totally null and void in the event the IonGen
™
is abused, misused, or used for a purpose other than for which the
product is intended. Failure to use as directed may result in loss or
injury to aquatic life. Aquascape, Inc is not responsible for any loss
of fish or aquatic life.
DISCLAImEr
Except as stated below, there are no other representatives or warranties re-
lated to the product or its use. THE USER SHALL DETERMINE THE SUITABILITY
OF THE PRODUCT FOR THE USER’S INTENDED USE, AND THE USER ASSUMES
ALL RISKS AND LIABILITIES WHATSOEVER IN CONNECTION THEREWITH.
Seller and manufacturer’s only obligation is the repair and or replacement
of the IonGen™ as stated below. ALL IMPLIED WARRANTIES ARE HEREBY
EXCLUDED, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Neither seller
nor the manufacturer shall be liable for any injury, loss, or
damage whether direct, incidental, or consequential arising out of the use
or inability to use the product.
1
YEAR
WARRANTY
1
GARANTIE
DE 1 AN
2
YEAR
WARRANTY
2
GARANTIE
DE 2 ANS
3
YEAR
WARRANTY
3
GARANTIE
DE 3 ANS
1
YEAR
WARRANTY
1
GARANTIE
DE 1 AN
2
YEAR
WARRANTY
2
GARANTIE
DE 2 ANS
3
YEAR
WARRANTY
3
GARANTIE
DE 3 ANS
Problem
Cause
Solution
8. Water flow reduction
Debris stuck on Probe
Remove Probe and clean debris and scale build-up off bars
9. Not able to raise ionizing indicator to
maximum bars
(NOTE: For serial numbered models
0005774 and below only. Serial
Number or S/N is located on white
label on cord.)
Manufacture setting in
Control Panel needs to be
adjusted
Remove back panel of Control Panel and turn the blue
potentiometer screw clockwise until maximum bars are able to
be reached using the Control Panel touch pad.
6
Continued from page 5
• Input Voltage: 120 Volts
• Input Frequency: 60 Hz
• Output Voltage: 12 V
• Output Current: 0.5A
• Plug-in Transformer: UL Listed,
CSA Listed Rainproof Class 2
• Flow Chamber: PVC TEE 2” slip x
2” slip x 2” fpt
• Probe Material: Optimum ratio
of 99% pure Copper, Silver, Zinc
• Capacity: Up to 25,000 gallon
water features
For more information about our company or products, please visit our website at www.aquascapeinc.com
or call us at (US) 1-866-877-6637 (CAN) 1-866-766-3426
IonGen
™
Specifications
Targeted Water Parameters
for Optimal Performance
To achieve the best results with the
IonGen
™
it is recommended that the
water feature’s water is within the
water parameters listed in the table
below. The water feature’s water
parameters can change during
the season, especially in features
that experience high evaporation.
Many times a simple water change
can help reset the water feature’s
water parameters. Alkalinity is an
important parameter for the proper
function of the IonGen
™
. One easy
way to raise low alkalinity is to use
ordinary baking soda. Adding ¼ cup
(0.15 pounds) per 1,000 gallons will
typically raise the alkalinity by 10
mg/L (ppm). Raising the alkalinity
should not be done all at once, but
over a period of days. One easy way
to lower alkalinity is performing a
water change.
Note:
It is not unusual
to have low copper level readings
on the test strips, no matter how
high the IonGen’s
™
ionization level
setting. This is due to the copper
being used within the water feature.
Periodic copper testing will ensure
that the levels stay below .25 ppm.
Copper
Less than 0.25
Alkalinity
100 – 250 ppm
Adjust small
screw