26
EN
OPERATION ERRORS
Despite careful production and control, the heat pump can produce errors that must
be solved by an authorised service provider.
Indicator of errors
In case of an error on the appliance, the beeper starts beeping and field no.
4
starts
flashing. When you press field no.
4
the error code is displayed in field no.
12
.
Error
Description of error
Solution
E004
Freezing. The error appears if the
temperature in the heat pump is below 4 °C.
Call the service.
E005
Overheating (temperature > 85 °C,
electronic regulator failure).
Unplug the heat pump from the
power supply. Call the service.
E006
Mg anode error.
Call the service (heat pump
functions normally).
E007
Volume and/or temperature sensors error.
Call the service.
E042
Anti-legionella function error.
Press field no. 4 to restart.
E247
Defrosting error.
Automatically turns on heating with
the electric heater. When the error
is deleted, the aggregate resumes
its normal operation.
E361
External air sensor error.
Call the service (automatically
switches to the electric heater).
E363
Defrosting sensor error.
Call the service (automatically
switches to the electric heater).
Summary of Contents for PAW-DHWM 80-120 ZNT
Page 1: ...PAW DHWM 80 120 ZNT ...
Page 24: ...24 EN ...
Page 48: ...48 DE reparieren sondern nehmen Sie mit dem nächsten autorisierten Kundendienst Kontakt auf ...
Page 120: ...120 DA ...
Page 144: ...144 NO ...
Page 168: ...168 SV ...
Page 192: ...192 HR BIH ...
Page 216: ...216 CS ...
Page 240: ...240 HU ...
Page 264: ...264 PL ...
Page 267: ...267 ...
Page 268: ...09 2014 479748 ...