background image

INSTALLATION AND OPERATING INSTRUCTIONS  

5

 

 

Note:

 Allow the refrigerant liquid inside the compressor at least 3 

minutes to settle before restarting. 

6.  The ‘ICE FULL’ indicator light will switch on and the unit will 

automatically stop making ice when ice basket is full. Press 
STOP and then START button to restart the ice maker after 
some of the ice has been removed from the ice basket.   

Note: 

Use the metal ice scoop included to gently separate any ice 

cubes that are stuck together. 

Note:

 Always use fresh water before starting ice production, either 

at initial installation or after a long shut-off period to maintain 
reasonable hygiene levels. Once you have finished using the 
machine any remaining ice or water should be removed and the 
unit cleaned.

CLEANING AND MAINTENANCE 

Before carrying out any maintenance or cleaning of the unit, make 
sure that the power to the unit is turned off and power cord is 
unplugged from the power socket. 

External cleaning of the unit: 

•  Do not clean unit with any abrasive cleaning agents or solvents.  

•  Use a damp cloth to wipe down the outside of the unit. Do not 

immerse unit in water.

•  Dry unit with a soft dry cloth. 

Internal cleaning of the unit: 

•  When cleaning, unplug the unit and remove any remaining ice 

cubes. 

•  Clean the internal parts (ice basket, water tank, evaporator etc.) 

frequently. 

•  Wipe down the interior of the unit using a soft cloth. Be sure to 

scrub it well to ensure any build-up is removed. You are welcome 
to use a small amount of vinegar to help further clean any 
impurities. 

•  Clean the water temperature sensor (located at the base of the 

water reservoir) at least once a week (Refer to fig. 2)

Fig 2

Summary of Contents for AQP-IM12C

Page 1: ...DELUXE COLLECTION Ice Maker AQP IM12C ...

Page 2: ...Maker Electrical Requirements Australia New Zealand 240V 230V 50Hz Note Please read through the instructions carefully before using or installing the product and ensure that the manual is kept in a safe place for future reference The system must be properly installed and located in accordance with the installation instructions before it is used During the set up of this product if you have any que...

Page 3: ...tension cord must have a rating equal to the rating of this appliance Unplug the power cord when not in use Do not use attachments not recommended or sold by the manufacturer as it may lead to fire electric shock or injury Position the appliance a minimum distance of 20cm away from walls curtains and other appliances and provide adequate space above and on all sides for air circulation Do not plac...

Page 4: ... basket 4 Water reservoir underneath ice basket 5 Handles PARTS IDENTIFICATION DIAGRAM System Specifications AQP IM12C Daily Ice Output 10 15kg 24 hours Ice Storage Capacity 1000g Water Reservoir Capacity 1 5L Refrigerant R134a Dimension 350 x 305 x 360 mm Net Weight 13 Kg 1 2 3 5 ...

Page 5: ...Large sized ice has been selected REFILL WATER Refill water light will illuminate and a beep will sound to indicate low water levels in the water reservoir Add more water to the water reservoir START Press to turn unit on and start the ice making cycle SELECT Ice selection S Small or L Large The default setting is L Large STOP Press to turn unit off or stop the ice making cycle DISPLAY PANEL AND C...

Page 6: ...appropriate electrical outlet Ensure that the unit is placed on a properly leveled surface 2 Open the lid and pour water into the water reservoir ensuring that the water level in the water reservoir is not over the ice collecting basket Refer to fig 1 Note Fill with potable municipal water only Only use drinking water 3 Close the lid and select desired ice cube size by pressing SELECT Note Please ...

Page 7: ...be removed and the unit cleaned CLEANING AND MAINTENANCE Before carrying out any maintenance or cleaning of the unit make sure that the power to the unit is turned off and power cord is unplugged from the power socket External cleaning of the unit Do not clean unit with any abrasive cleaning agents or solvents Use a damp cloth to wipe down the outside of the unit Do not immerse unit in water Dry u...

Page 8: ...of vinegar into the water 2 Make ice for several batches and discard the ice 3 Empty any remaining water from the water reservoir 4 Add clean drinking water into the water reservoir and make ice for several batches and discard the ice This is to ensure any leftover vinegar or impurities have been completely removed from the machine 5 Drain all the water from the water reservoir It is recommended t...

Page 9: ...n stopper in the bottom of the reservoir and let several drops of water run out Ice making cycle is normal but no ice formed Room temperature or water temperature in inner tank is too high The room temperature should be 10 35 C water temperature should be 8 32 C Refrigerant in cooling system has leaked Contact Customer Service Pipe in cooling system is blocked Contact Customer Service The ICE FULL...

Page 10: ...r reservoir is full START button was not pushed after water was added to the water reservoir Press the STOP button wait 3 minutes and press the START button to restart The ice maker will restart automatically Ice full indicator light not on but machine full of ice Sensor has not had time to register Ice Full indicator is operated by a temperature sensor ensure lid is closed and allow time for sens...

Page 11: ...or any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure Register your warranty online at www aquaport com au warranty Conditions of this warranty 1 This product has been fully installed in accordance with the user manual installation instructions 2 Th...

Page 12: ...CUSTOMER CARE 1300 764 325 Aquaport Corporation Pty Ltd 66 70 Hardys Road Torrensville SA 5031 Phone 08 8354 0711 Facsimile 08 8354 0722 Email aquaport aquaport com au www aquaport com au ...

Reviews: