Installation of the connecting assembly*

* The manufacturer reserves the right to use connecting assemblies and taps of a similar design. If you have any questions, 

please, contact the service department.

•  Turn water off at the mainline.

•  Open the kitchen faucet to relieve pressure in 

the water supply system.

•  Unscrew the clamping nut from the flexible 

hose in the cold water supply line to the faucet.

ATTENTION! The flexible hose may contain a 
little water after depressurizing. When discon-
necting the flexible hose, use a 200 ml vessel 
to drain the residual water.

•  Screw the clamping nut of the connecting 

assembly onto the thread of the cold water 

supply.

•  Screw the clamping nut of the flexible hose 

onto the thread of the connecting assembly.

•  Close the inlet cock of the connecting assembly 

and supply water from the cold water supply 

line to make sure that the connection is tight.

•  Connect the corresponding JG tube.

Fig. 5b

Fig. 4

Fig. 5a

The inlet cock  
is in its closed position

Retaining clip

Connecting assembly

Gasket

Cold water supply

How to connect the JG tubes (Fig. 5a)

Pull the retaining clip out from under the plastic 

sleeve, insert the pre-moistened end of the tube 

into the plastic sleeve until it stops about 15 mm 

deep and install the clip.

How to disconnect the JG tubes (Fig. 5b) 

Pull the retaining clip out from under the plastic 

sleeve and pull the tube out by pressing on the 

end of the plastic sleeve.

Check that the tube is tight. The tube should not be pulled out using a force of 80-100 N.

ATTENTION! The end of the pipeline must be flat at the point, where the connecting assembly 
is connected. Do not use excessive force when tightening the clamping nut.
Otherwise, it will damage the gasket.

Summary of Contents for RO-206S

Page 1: ...RO 206S REVERSE OSMOSIS SYSTEM Operation manual...

Page 2: ...so the higher the water salinity the greater water supply pressure is required to keep RO 206S operating RO 206S is made of safe non toxic materials ensuring that no substances hazardous to both human...

Page 3: ...L 1 3 m red 1 pc 3 2 1 4 JG tube d 6 35 mm L 1 2 m black 1 pc 3 3 1 4 JG tube d 6 35 mm L 1 0 m blue with an inserted metal bushing 1 pc 4 Connecting assembly 7 1 set 5 Drain clamp 8 1 set 6 Service...

Page 4: ...uantity at any time At the front the RO 206S housing is covered with a decorative panel where an electronics unit and control elements are located 2 K1 and K2 replaceable filter cartridges are part of...

Page 5: ...be paid to prevent the supply tubes from bending and twisting Fig 3 Your RO 206S must be installed far from or insu lated from heat sources stoves boilers hot water pipes dishwashers washing machines...

Page 6: ...nlet cock of the connecting assembly and supply water from the cold water supply line to make sure that the connection is tight Connect the corresponding JG tube Fig 5b Fig 4 Fig 5a The inlet cock is...

Page 7: ...The bolts should be tightened evenly so that the two parts of the clamp are parallel Put the plastic nut on the JG drain tube so that the tube extends from the other side of the nut by at least 20 mm...

Page 8: ...ion The cartridge life indicator lights blink the light signal is followed by an audible signal On the front panel of your RO 206S Fig 13 flash the PUSH button 3 times to start the flushing mode At th...

Page 9: ...206S is ready for use once the tank is filled ATTENTION The water is not intended for drink ing after flushing Periodically check your RO 206S for leaks during the first week of use Some noise may occ...

Page 10: ...rtridge into the corresponding collector until it stops and turn clockwise as shown in Fig 10a until a click Replacement of K1 K2 filter cartridges and the membranes cartridges Modes Sound alarm LED o...

Page 11: ...f the connecting assembly The cartridge life light indicators turn on the flashing light indicator of the reverse osmosis membrane unit is followed by a sound signal Make sure the RO 206S connections...

Page 12: ...tems that meet sanitary standards It is recommended to analyse the water source for compliance with national standards for drinking water when installing RO 202S outside municipal water supply systems...

Page 13: ...prehensive warranties in the industry Aquaphor warrants that the Aquaphor water filtration system shall be free from defects in material and workman ship under normal use and service Aquaphor Reverse...

Page 14: ...EXCLUSION MAY NOT APPLY TO YOU If you have any issue with the operation of your RO 206S please contact the seller or the manufacturer Service life operating time of replaceable filtering cartridges N...

Page 15: ...er supply plug is not plugged into the outlet Insert the plug of the power supply into a power outlet The power supply plug is not plugged into the coaxial connector of the RO 206S Insert the power su...

Page 16: ...r Corp L Tolstoi 2A Sillam e Estonia 40231 www aquaphor com The manufacturer reserves the right to make improvements to the design of the RO 206S without being mentioned in this Manual The date of man...

Reviews: