AQUAPHOR RO-206S Operation Manual Download Page 12

12

Connecting an additional tank

In the general case, the connection diagram 

for an additional hydraulic accumulator tank is 

shown in Fig. 16. 
Depending on the specific parameters of the 

accumulation tank and the connection conditions, 

it may be necessary to adjust the operating mode 

of the electronic RO-206S control unit. Contact 

a service representative for advice.

10. Storage and 

Transportation Rules 

The RO-206S shelf life is 3 years before operation 

when stored at + 5 to + 38 ºС, originally packed, in 

closed and naturally ventilated rooms at a relative 

humidity not exceeding 80%.
It is forbidden to turn the RO-206S over, to hit or 

to expose to other mechanical stresses.
Protect your RO-206S from shocks and falls, 

as well as not letting any water freeze when 

transporting, storing and using.
Do not expose the membrane cartridges to high 

or low temperatures and direct sunlight. 

Attention! Membranes cartridges come in sealed 
packaging. It is allowed to store membrane car-
tridges for no more than 3 days after they are 
unpacked.

11. Safety

RO-206S is designed to post-treat and soften 

water from municipal water supply systems that 

meet sanitary standards.
It is recommended to analyse the water source for 

compliance with national standards for drinking 

water when installing RO-202S outside municipal 

water supply systems.

•  The service life of the pre-treatment unit and 

the reverse osmosis membranes may be 

reduced if the source water does not meet 

the requirements of national standards for 

drinking water.

•  It is recommended to install additional water 

treatment systems (iron removers, softeners, 

disinfectants, mechanical filters, etc.) if the 

source water significantly differs from the 

requirements of national standards for drinking 

water quality.

•  It is recommended to use RO-206S as a post-

treatment unit for microbiologically safe water, 

although this reverse osmosis system can trap 

out bacteria and viruses from the source water. 

Do not use the system to treat unknown water 

without additional disinfection. Empty and 

refill the tank 3 times for flushing before use 

if you have not used your system for more 

than 2 weeks. Treated water is not subject to 

long-term storage. It is recommended to use 

fresh filtered water.

It is disposed of in accordance with environmental, 

sanitary and other requirements set forth in 

national standards for environmental protection 

and ensuring the sanitary and epidemiological 

welfare of the population.

Summary of Contents for RO-206S

Page 1: ...RO 206S REVERSE OSMOSIS SYSTEM Operation manual...

Page 2: ...so the higher the water salinity the greater water supply pressure is required to keep RO 206S operating RO 206S is made of safe non toxic materials ensuring that no substances hazardous to both human...

Page 3: ...L 1 3 m red 1 pc 3 2 1 4 JG tube d 6 35 mm L 1 2 m black 1 pc 3 3 1 4 JG tube d 6 35 mm L 1 0 m blue with an inserted metal bushing 1 pc 4 Connecting assembly 7 1 set 5 Drain clamp 8 1 set 6 Service...

Page 4: ...uantity at any time At the front the RO 206S housing is covered with a decorative panel where an electronics unit and control elements are located 2 K1 and K2 replaceable filter cartridges are part of...

Page 5: ...be paid to prevent the supply tubes from bending and twisting Fig 3 Your RO 206S must be installed far from or insu lated from heat sources stoves boilers hot water pipes dishwashers washing machines...

Page 6: ...nlet cock of the connecting assembly and supply water from the cold water supply line to make sure that the connection is tight Connect the corresponding JG tube Fig 5b Fig 4 Fig 5a The inlet cock is...

Page 7: ...The bolts should be tightened evenly so that the two parts of the clamp are parallel Put the plastic nut on the JG drain tube so that the tube extends from the other side of the nut by at least 20 mm...

Page 8: ...ion The cartridge life indicator lights blink the light signal is followed by an audible signal On the front panel of your RO 206S Fig 13 flash the PUSH button 3 times to start the flushing mode At th...

Page 9: ...206S is ready for use once the tank is filled ATTENTION The water is not intended for drink ing after flushing Periodically check your RO 206S for leaks during the first week of use Some noise may occ...

Page 10: ...rtridge into the corresponding collector until it stops and turn clockwise as shown in Fig 10a until a click Replacement of K1 K2 filter cartridges and the membranes cartridges Modes Sound alarm LED o...

Page 11: ...f the connecting assembly The cartridge life light indicators turn on the flashing light indicator of the reverse osmosis membrane unit is followed by a sound signal Make sure the RO 206S connections...

Page 12: ...tems that meet sanitary standards It is recommended to analyse the water source for compliance with national standards for drinking water when installing RO 202S outside municipal water supply systems...

Page 13: ...prehensive warranties in the industry Aquaphor warrants that the Aquaphor water filtration system shall be free from defects in material and workman ship under normal use and service Aquaphor Reverse...

Page 14: ...EXCLUSION MAY NOT APPLY TO YOU If you have any issue with the operation of your RO 206S please contact the seller or the manufacturer Service life operating time of replaceable filtering cartridges N...

Page 15: ...er supply plug is not plugged into the outlet Insert the plug of the power supply into a power outlet The power supply plug is not plugged into the coaxial connector of the RO 206S Insert the power su...

Page 16: ...r Corp L Tolstoi 2A Sillam e Estonia 40231 www aquaphor com The manufacturer reserves the right to make improvements to the design of the RO 206S without being mentioned in this Manual The date of man...