10
5
2
1
4
3
Fig. 15
The solid indicators of the filtration units
inform
about the unexpired service life of the cartridges.
Light indicator 5
(see Fig. 15) starts flashing in the
event of a malfunction; it stays solid the rest of the
• Close the inlet cock of the connecting assembly
and open the treated water tap. Wait until the
cartridge life light and sound indication turns
off.
• Remove the overwrapping film from the new
cartridges.
• Rinse the O-rings of the new cartridge under
a water stream.
• Remove the old cartridges. For this, press
the lock button as far as it will go and hold it
while turning the cartridge counter clockwise,
as shown in Fig. 10b.
• Insert a new cartridge into the corresponding
collector until it stops and turn clockwise, as
shown in Fig. 10a, until a click.
Replacement of K1, K2 filter cartridges
and the membranes cartridges
Modes
Sound alarm
LED operation by numbers
(see Fig. 15)
Pump
operation
Solid
Flashing
Filling the tank with treated water
(Operating mode)
1–5
+
The tank is filled (Standby mode)
5
Launch and flush modes
The system starts for the first time
+
5
1–4
+
Flushing the pre-treatment unit
5
1–4
+
Flushing the membrane unit
+
5
1–4
+
Cartridge expired service life indication
Filling the tank with treated water
(Operating mode)
+
5
Corresponds to the
cartridge (s) that has
exceeded its life cycle
+
Fault mode (Emergency mode*)
+
Alternately: (1, 3, 5) / (2, 4)
* After disconnecting and then connecting the water purifier to the main body, the sound signal stops.
time, informing that your RO-206S is connected to
the power supply.