background image

12 

 

 

 

 

10/9/2013  

               Drinking Water Machine

Installation Guide

Drinking Water Machine  

 

 

10/9/2013   

 

 

                13

Installation Guide

Step 3    

Prepare the Sink for Spigot Installation

The most convenient installation would allow the use of an existing spray attachment hole. If the spray 

attachment hole is not available, then follow the basic procedures outlined below.

Drilling a stainless steel sink:

A.

 Mark the sink location for the center of the spigot.

B.

 Impact punch the sink top to provide a starting point for the drill bit.

C.

 Drill a 1/4-inch pilot hole in the sink using a high-speed drill bit.

D.

 Drill a 1/2-inch diameter hole to accept the bolt of a 1-inch Greenlee Chassis Punch.

E.

 Set the punch and turn the nut with a wrench to cut the hole. Follow Greenlee instructions.

Drilling a porcelain clad steel or cast-iron sink:

A.

 Mark the sink location for the center of the spigot. Be sure 

the location you select is not over a reinforcing rib. Check the 

location from under the sink.

B.

 Grind away a 1-inch diameter circle in the porcelain 

using a silicon/carbide wheel and high-speed grinder (See 

Installation Tool List

), down to the metal surface of the sink. 

(See Figure 4).

C.

 Impact punch a small indent in the center of the area 

ground away.

D.

 Drill a 1/4-inch pilot hole through the metal base using a 

standard high-speed drill bit.

Caution:

 Be careful when the drill is about to penetrate the base metal of the sink. Reduce the speed and 

support the drill so the drill chuck does not impact the porcelain or enamel.

E.

 Use the pilot hole as a guide to drill a 1-inch diameter hole with carbide bits to mount the spigot.

Step 4    

Prepare the Air Gap Spigot Assembly for Installation

A.

 Assemble the spigot with all of the components (See Figure 16) according to the spigot assembly 

instructions included with the spigot.

B.

 Feed the assembled spigot and tubing through the hole in the sink and fasten from under the sink according 

to the instructions.

C.

 Position the spigot for customer convenience and then secure the spigot on the sink.

Step 5    

Install the Incoming Water Supply Valve

For installation with standard angle stop incoming water supply valve.

A.

 Shut off the water at the angle stop valve.

B.

 Use a wrench to loosen the compression nut on the angle stop riser tube.

C.

 Install the incoming water supply valve onto the angle stop. Use the wrench to tighten the compression nut 

on the incoming water supply valve. Do not overtighten!

D.

 Reconnect the riser tube to the other end of the incoming 

water supply valve. Do not overtighten!

Caution:

 A longer riser tube assembly will be required if a 

gentle loop cannot be made. (See Figure 5).

E.

 Remove the red locking clip from the incoming water 

supply valve. Fully insert the blue 3/8-inch tube into the speedfit 

connection and replace the red locking clip. The new incoming 

water valve can be swiveled to position the tubing out of the way.

F.

 Make sure the incoming water supply valve is off before 

turning the angle stop valve on. Check for leaks.

Figure 6: Installation with Flexible Hose

Installation Steps and Start-Up Procedures, Cont.

Installation Steps and Start-Up Procedures, Cont.

Figure 4: Grinding Wheel

Figure 5: Flexible Hose Positions

Summary of Contents for DWM-101

Page 1: ...ing Water Machine AQUAPHOR DWM 101 System Tested and certified by NSF International against NSF ANSI Standard 58 for the reduction of claims specified on performance data sheet INSTALLATION GUIDE VERSION 1 2 ...

Page 2: ... iron algae sulphur tannins organic matter or other unusual substances then unless the appliance is represented as being capable of handling these substances in the appliance specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise AQUAPHOR shall have no obligations under this warranty This warranty does not cover d...

Page 3: ...coming water pressure and the water temperature This appliance is designed with a self regulating flush feature that limits the reject water to approximately 5 gallons 19 L for every gallon liter of treated water Your appliance will perform better and last longer with heavy use We encourage you to water house plants provide water for pets cook mix drinks fill batteries etc with treated water Cauti...

Page 4: ...e for convenient use 6 Appliance Shutoff Valve Consists of the supply line to the spigot blue supply line to the appliance and the incoming water supply line Turn this lever to shut off the water to the appliance from the incoming water supply 7 DWM Assembly The DWM assembly contains a decorative cover that is attached by three plastic fasteners four twist lock fittings for attaching the replaceab...

Page 5: ... this checklist before installation The Drinking Water Machine is designed to be used for the treatment of municipally treated water or pre treated well water A water softener or additional types of pretreatment are highly recommended should your water not meet water quality or characteristics standards Water Quality If the water supply contains bacterial iron algae sulphur tannins organic matter ...

Page 6: ...ee Figure 1 before proceeding to familiarize yourself with the general layout of the appliance Step 2 Check Fit Ensure that the complete appliance will fit in the installation location before proceeding Check all factory fittings and tubing connections Be sure all locking clips are in place See steps A through F below for tube connection instructions A Cut the tube square It is essential that the ...

Page 7: ...elain or enamel E Use the pilot hole as a guide to drill a 1 inch diameter hole with carbide bits to mount the spigot Step 4 Prepare the Air Gap Spigot Assembly for Installation A Assemble the spigot with all of the components See Figure 16 according to the spigot assembly instructions included with the spigot B Feed the assembled spigot and tubing through the hole in the sink and fasten from unde...

Page 8: ...e the flanges with tap water Caution Do not touch the filter s with your bare hands Peel the wrapper and use as a sleeve to prevent contamination Lubricate O Rings with glycerin Never use a petroleum based lubricant where it can contact the O Rings D Install the cartridges in the Rinsing position according to the numbered locking buttons located on the sides of the manifolds See Table 1 E Insert c...

Page 9: ...tart Up Procedures Cont Installation Steps and Start Up Procedures Cont Figure 11 Incoming Water Supply Valve Figure 12 Unscrew the Cover of the Membrane Cartridge F Repeat steps E five 5 more times G After the storage tank is filled up for the seventh time the water is now ready to use Important To maintain the highest quality of water AQUAPHOR recommends that if the treated water is not used for...

Page 10: ...ace any clogged cartridges See Changing the Filter Cartridges 1 2 and 4 J Replace any filter cartridge or RO Membrane 3 as deemed fouled after the testing process Turn on the incoming water valve to the appliance K Turn on the treated water spigot and verify flow of water If the water flow is still reduced repeat steps C J to determine if a second cartridge is clogged If water flow is normal proce...

Page 11: ... tank with the Tank Flange Key 4 Examine the membrane neck for damage and inspect and or replace the O Ring 5 Lubricate the O Ring and storage bladder neck with glycerin before re installing the tank flange 6 Reconnect the blue tube to the water fitting at top center of the storage tank and reinstall the I O Valve assembly C Ensure there are no leaks and then replace the decorative cover Unusual S...

Page 12: ... Assembly Lead Free Figure 16 Air Gap Spigot Assembly Lead Free treated water spigot Part Description Quantity 10005 Air Gap Spigot Assembly Lead Free 1 DWM Assembly Figure 17 DWM Assembly Part Description Quantity 1 10015 Input Output Valve assembly 1 2 10020 Valve Assembly 1 Assembly and Parts Cont Assembly and Parts Cont ...

Page 13: ...ct the tube from the drain saddle and clean out the debris or replace the drain line Broken handle or spout Fatigue or misuse Replace the spigot assembly Unusual sounds during operation Problem with one of the restrictors See Maintenance Procedures Troubleshooting Model Part AQUAPHOR DWM 101 RO Membrane 3 TFC ULP Production Rates Gallons per day1 Liters per day1 NSF gpd2 NSF lpd2 52 5 198 36 87 13...

Page 14: ...26 10 9 2013 Drinking Water Machine Installation Guide Drinking Water Machine 10 9 2013 27 Installation Guide Notes Notes ...

Page 15: ...P O Box 298 Groveport OH 43125 Phone 614 836 9422 Fax 614 836 9876 2013 Drinking Water Machine AQUAPHOR DWM 101 ...

Reviews: