background image

18 

 

 

 

 

10/9/2013  

               Drinking Water Machine

Installation Guide

Drinking Water Machine  

 

 

10/9/2013   

 

 

                19

Installation Guide

Figure 13: Input/Output (I/O) Valve

Warning:

 Shut off water to the appliance before beginning any maintenance.

Caution:

 Drain the tank by opening the treated water spigot before disconnecting the tubes or before removing 

any cartridges from the DWM assembly.

Checking and Replacing the RO Membrane (3) and Filter Cartridges (1, 2, and 4)

A.

 Remove the decorative cover from the appliance.

B.

 Remove the RO membrane (3) and replace it with the 

rinsing cap.

C.

 Turn on the incoming water valve to the appliance.

D.

 Turn on the treated water spigot and verify the flow of water.

E.

  If  the  water  flow  is  normal,  replace  the  clogged  RO 

Membrane (3). 

See Changing the RO Membrane (3)

. If the water 

flow is still reduced, proceed to the next step.

F.

 Turn off the treated water spigot. Remove the Replacement 

filter cartridge K5 (1) in position 1. Turn on the water and verify the 

flow of water through the spigot. If the flow is normal, Replacement filter 

cartridge K5 (1) may be clogged. If water flow is still reduced, proceed to the next step.

G.

 Turn off the treated water spigot. Remove the Replacement filter cartridge K2 (2) from position 2. Turn on 

the water and verify the flow of water through the spigot. If the flow is normal, the Replacement filter cartridge K2 (2) 

may be clogged. If water flow is still reduced, proceed to the next step.

H.

 Turn off the treated water spigot. Remove the Replacement filter cartridge K7M (4) from position 4. Turn 

on the water and verify the flow of water through the spigot. If the flow is normal, the Replacement filter cartridge 

K7M (4) may be clogged.

I.

 Replace any clogged cartridges. 

See Changing the Filter Cartridges (1, 2, and 4)

.

J.

 Replace any filter cartridge or RO Membrane (3) as deemed fouled after the testing process. Turn on the 

incoming water valve to the appliance.

K.

 Turn on the treated water spigot and verify flow of water. If the water flow is still reduced, repeat steps C–J 

to determine if a second cartridge is clogged. If water flow is normal, proceed to the next step.

L.

 Ensure there are no leaks and then replace the decorative cover.

Checking and Replacing the I/O Valve Assembly

A. Disconnect the external drain line from the drain saddle and the white membrane drain line from the back 

of the I/O Valve.

B. Place both lines into a bucket and verify the flow of water.
C. Open the treated water spigot and allow the appliance to flush for 5 seconds. Close the spigot and allow 

the tank to refill (approximately 2–3 minutes).

D. While the tank is refilling, water should flow through both the white membrane drain line and the external 

drain line into the bucket.

E. When the tank is filled, the I/O Valve should shut off the water to both drain lines. If the water continues to 

flow through both drain lines, continue with steps F–M to replace the I/O Valve assembly.

F. Remove the decorative cover from the appliance.
G. Remove the locking clips and tubes from all ports on the valve assembly.
H. Unscrew both mounting screws.

Caution:

 Do not press down hard on the screws. Doing so may push the screws out of the plastic. 

I. Remove the valve assembly, retaining the O-Rings. 
J. Install the O-Rings on the new valve assembly
K. Position the new valve assembly and screw in the mounting screws until snug. 

Do not overtighten! 

L. Reconnect all tubes to their appropriate locations and reinstall the locking clips. 
M. Ensure there are no leaks and then replace the decorative cover.

Maintenance Procedures

Maintenance Procedures, Cont.

Summary of Contents for DWM-101

Page 1: ...ing Water Machine AQUAPHOR DWM 101 System Tested and certified by NSF International against NSF ANSI Standard 58 for the reduction of claims specified on performance data sheet INSTALLATION GUIDE VERSION 1 2 ...

Page 2: ... iron algae sulphur tannins organic matter or other unusual substances then unless the appliance is represented as being capable of handling these substances in the appliance specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise AQUAPHOR shall have no obligations under this warranty This warranty does not cover d...

Page 3: ...coming water pressure and the water temperature This appliance is designed with a self regulating flush feature that limits the reject water to approximately 5 gallons 19 L for every gallon liter of treated water Your appliance will perform better and last longer with heavy use We encourage you to water house plants provide water for pets cook mix drinks fill batteries etc with treated water Cauti...

Page 4: ...e for convenient use 6 Appliance Shutoff Valve Consists of the supply line to the spigot blue supply line to the appliance and the incoming water supply line Turn this lever to shut off the water to the appliance from the incoming water supply 7 DWM Assembly The DWM assembly contains a decorative cover that is attached by three plastic fasteners four twist lock fittings for attaching the replaceab...

Page 5: ... this checklist before installation The Drinking Water Machine is designed to be used for the treatment of municipally treated water or pre treated well water A water softener or additional types of pretreatment are highly recommended should your water not meet water quality or characteristics standards Water Quality If the water supply contains bacterial iron algae sulphur tannins organic matter ...

Page 6: ...ee Figure 1 before proceeding to familiarize yourself with the general layout of the appliance Step 2 Check Fit Ensure that the complete appliance will fit in the installation location before proceeding Check all factory fittings and tubing connections Be sure all locking clips are in place See steps A through F below for tube connection instructions A Cut the tube square It is essential that the ...

Page 7: ...elain or enamel E Use the pilot hole as a guide to drill a 1 inch diameter hole with carbide bits to mount the spigot Step 4 Prepare the Air Gap Spigot Assembly for Installation A Assemble the spigot with all of the components See Figure 16 according to the spigot assembly instructions included with the spigot B Feed the assembled spigot and tubing through the hole in the sink and fasten from unde...

Page 8: ...e the flanges with tap water Caution Do not touch the filter s with your bare hands Peel the wrapper and use as a sleeve to prevent contamination Lubricate O Rings with glycerin Never use a petroleum based lubricant where it can contact the O Rings D Install the cartridges in the Rinsing position according to the numbered locking buttons located on the sides of the manifolds See Table 1 E Insert c...

Page 9: ...tart Up Procedures Cont Installation Steps and Start Up Procedures Cont Figure 11 Incoming Water Supply Valve Figure 12 Unscrew the Cover of the Membrane Cartridge F Repeat steps E five 5 more times G After the storage tank is filled up for the seventh time the water is now ready to use Important To maintain the highest quality of water AQUAPHOR recommends that if the treated water is not used for...

Page 10: ...ace any clogged cartridges See Changing the Filter Cartridges 1 2 and 4 J Replace any filter cartridge or RO Membrane 3 as deemed fouled after the testing process Turn on the incoming water valve to the appliance K Turn on the treated water spigot and verify flow of water If the water flow is still reduced repeat steps C J to determine if a second cartridge is clogged If water flow is normal proce...

Page 11: ... tank with the Tank Flange Key 4 Examine the membrane neck for damage and inspect and or replace the O Ring 5 Lubricate the O Ring and storage bladder neck with glycerin before re installing the tank flange 6 Reconnect the blue tube to the water fitting at top center of the storage tank and reinstall the I O Valve assembly C Ensure there are no leaks and then replace the decorative cover Unusual S...

Page 12: ... Assembly Lead Free Figure 16 Air Gap Spigot Assembly Lead Free treated water spigot Part Description Quantity 10005 Air Gap Spigot Assembly Lead Free 1 DWM Assembly Figure 17 DWM Assembly Part Description Quantity 1 10015 Input Output Valve assembly 1 2 10020 Valve Assembly 1 Assembly and Parts Cont Assembly and Parts Cont ...

Page 13: ...ct the tube from the drain saddle and clean out the debris or replace the drain line Broken handle or spout Fatigue or misuse Replace the spigot assembly Unusual sounds during operation Problem with one of the restrictors See Maintenance Procedures Troubleshooting Model Part AQUAPHOR DWM 101 RO Membrane 3 TFC ULP Production Rates Gallons per day1 Liters per day1 NSF gpd2 NSF lpd2 52 5 198 36 87 13...

Page 14: ...26 10 9 2013 Drinking Water Machine Installation Guide Drinking Water Machine 10 9 2013 27 Installation Guide Notes Notes ...

Page 15: ...P O Box 298 Groveport OH 43125 Phone 614 836 9422 Fax 614 836 9876 2013 Drinking Water Machine AQUAPHOR DWM 101 ...

Reviews: