background image

4.

Soldering of joints near the drain port must be done prior to

connecting the Drain Line Flow Control fitting (DLFC). Leave

at least 6" (15 cm) between the DLFC and solder joints

 

when

soldering pipes that are connected on the DLFC.

 

Failure to

do this could cause interior damage to the DLFC.

5.

Plumber tape is the only sealant to be used on the drain

fitting.

6.

Make sure that the floor is clean beneath the salt storage

tank and that the tank is level.

7. Add 2 gallons of water to the brine tank.
8. On units with a bypass, place in bypass position. Turn on the

main water supply. Open a cold soft water tap nearby and let run a

few minutes or until the plumbing is free from foreign material

(usually solder) that may have resulted from the installation. Once

clean, close the water tap.

9. Slowly place the bypass in service position and let water flow into

the mineral tank. When water flow stops, slowly open a cold water

tap nearby and let water run until the air is purged from the unit.

10. Plug the transformer into an electrical outlet.

NOTE: All electrical connections must be connected 
according

 to local codes. Be certain the outlet is uninterrupted.

60002 Rev E

Figure 1 Residential Air Check Valve 

Electrical Connection

The controller operates on 12-volt DC power supply. This 

requires use of the supplied power adapter included with your 

system.

NOTE:  The power source should be constant. Be certain the 

power adapter is not on a switched outlet. Power 

interruptions longer than eight hours may cause the 

controller to lose the time setting. When power is 

restored, the time setting must then be re-entered.

INSTALLATION

Water Pressure

A minimum of 20 psi (1.4 bar) of water pressure is required for 

the regeneration valve to operate effectively.

Electrical Facilities 

An uninterrupted power supply is required. The control uses a 

transformer to supply 12 VDC. Please make sure your voltage 

supply is compatible with your unit before installation.

Existing Plumbing

Condition of existing plumbing should be free from lime and 

iron buildup. Piping that is built up heavily with lime and/or iron 

should be replaced. If piping is clogged with iron, a separate 

iron filter unit should be installed ahead of the system.

Location Of System And Drain

The system should be located close to a drain to prevent air 

breaks and back flow.

Outdoor Locations

When the water conditioning system is installed outdoors, 

several items must be considered.

• Moisture — The system is not designed to withstand

extreme humidity or water spray from below. Examples

are: constant heavy mist, near corrosive environment,

upwards spray from sprinkler.

CAUTION

 This unit is for dry location use only unless used 

with a Listed Class 2 power supply suitable for 

outdoor use.

• Direct Sunlight — The materials used will fade or

discolor over time in direct sunlight. The integrity of the

materials will not degrade to cause system failures. If

it is necessary to locate the system in direct sunlight, a

protective outdoor cover (P/N 61882) over the valve and

controller is necessary.

• Insects — If installing in an environment that may expose

the system to insects or other small animals, a protective

cover is required. The protective outdoor cover (P/N

61882) has been designed to keep all but the smallest

insects out of the critical areas. The cover should be

installed securely in place.

Bypass Valves

Always provide for the installation of a bypass valve if unit is not 

equipped with one.

CAUTION

 Water pressure is not to exceed 125 psi (8.6 bar), 

water temperature is not to exceed 110°F (43°C), 

and the unit cannot be subjected to freezing 

conditions.

WARNING:

 The system must be depressurized before 

removing any connections for servicing.

Installation Instructions

1. Place the media tank where you want to install the unit.

Make sure the unit is level and on a firm base.

2. During cold weather, the installer should warm the valve to

room temperature before operating.

3. All plumbing should be done in accordance with local

plumbing codes. The pipe size for a residential drain line

should be a minimum of 1/2" (13 mm). Backwash flow rates

in excess of 7 gpm (26.5 Lpm) or drain line length in excess

of 20' (6 m) require 3/4" (19 mm) drain line. Commercial

drain lines should be the same size as the drain line flow

control.

Fleck 

5800 XTR2 

Quick Start

 Manual • 

2

Summary of Contents for FLECK 5800 XTR2

Page 1: ...FLECK 5800 XTR2 Quick Start MANUAL 10 66 Brine Tank Dimensions 14 wide x 17 deep x 38 tall ...

Page 2: ...is built up heavily with lime and or iron should be replaced If piping is clogged with iron a separate iron filter unit should be installed ahead of the system Location Of System And Drain The system should be located close to a drain to prevent air breaks and back flow Outdoor Locations When the water conditioning system is installed outdoors several items must be considered Moisture The system i...

Page 3: ...utton the number of times that correspond with the position of the correct letter on the button For example to enter the letter C quickly press the ABC button three times Press when finished 3 After pressing the Assistance Phone screen Figure 5 is displayed Figure 5 Assistance Phone Screen Enter the phone number of the water treatment professional or company that the homeowner may call for system ...

Page 4: ... The Regeneration screen appears Figure 9 Figure 9 Regeneration Screen Press the now button to begin a regeneration immediately 7 The valve will cycle to backwash Ensure the drain line flow remains steady for 10 minutes or until the water runs clear 8 Press the button to cycle to the brine slow rinse Draw position Ensure the unit is drawing water from the brine tank 9 Press the button to cycle to ...

Page 5: ... complexity of these settings and the potential for errors Master Settings should only be accessed by your local water professional Diagnostics Displays the Diagnostic screen which can assist in performing maintenance and troubleshooting performance issues with the valve Assistance Displays a name and phone number to call for unit service Screen Navigation Arrows Displayed in the upper left and up...

Page 6: ...ed regeneration in either time or volume depending on control settings Day and Time Regeneration Settings Regeneration Cycle Wheel Next Scheduled Regeneration Current Cycle Step Diagnostics Assistance Day and Time Displays the currently programmed day of the week and time This button will flash if the control has been reset Regeneration Regenerate the system on demand by pressing the Regeneration ...

Page 7: ...Due to the complexity of these settings and the potential for errors Master Settings should only be accessed by your local water professional NOTE Settings can not be accessed during a regeneration If a regeneration starts while in the settings menu the screen will return to the main screen and all parameters will be voided Master Settings User Assistance The Assistance screen displays the name an...

Reviews: