6
4
Mounting
CAUTION
Material damage caused by neglected ambient/environment conditions
Danger of malfunction or damage!
•
Assuring accessibility for installation, operation and maintenance
•
Mount to rigid object to avoid excessive vibrations
•
Use provided mounting holes
1.
Use provided mounting holes
5
Installation
5.1
Mechanical Installation
Identify the flowmeter and ensure that the flowmeter is suitable for the intended process and
conditions. Easy access for reading the flow meter and controlling the ancillary equipment is im-
portant. Provided that the arrow on the housing is in the direction of flow, the flow meter can be
installed in any position without any special modifications.
NOTE
Exception
•
Do not install upside down
✓