9. Go to the <Supply Configuration>
a. Check the <SL KF>. Is it the right one?
b. If not, go back to the section <How to connect …> and take the appropriate corrections.
10. Go to the <Return Configuration>
a. Check the <RL KF>. Is it the right one?
b. If not, go back to the section <How to connect …> and take the appropriate corrections.
Operating Instruction for the
Board Computer (DFM-BC)
The Board Computer (DFM-BC) has no ON/OFF switch. It has a sleep mode.
What does it mean?
When no activities are recognized on the connected lines (Supply line and Return Line) the Board Computer (DFM-BC) will switch itself OFF.
It will be woken up when more than 2 pulses are coming in over the connected lines.
The consumed power is very low (less than 1 mA), so that no discharge of the vehicle battery should occur during a very long period.
The Menu structure
has 3 branches:
•
User-Mode
Is intended for the daily user. It informs him about the daily needed information.
•
Info-Mode
Is intended for the advanced user. It shows you deeper information about the DFM-System. No parameter changes are possible.
•
Service-Mode.
Service-Mode is only for the Service-Engineer and is password protected. Because you have complete access to all parameters, it is
absolutely important to be a trained and qualified person. Inaccurate changes in this section can result in fault calculations and mista-
kes.
For User ... daily information (User Mode)
Total Consumption
This picture shows the total consumption of the Engine since commissioning.
Last screen
Next screen
TRIP
This picture shows the consumption of the Engine since the last reset.
Previous screen
Next screen
Reset
the
TRIP
This function is activated in dependence of the setting in the section
Service Mode
.
Press OK
to
Press OK
enter the reset
again to reset
mode
the
TRIP
After this, the TRIP will show 0 l/h