9. Technical Data

Measurement range: 0 - 10,00 mS/cm

Resolution:

0,01 mS

Accuracy:

+/- 2,5 % of range +/- 1 digit (Inst.)

Electrode:

PETP shaft; Electrode material: graphite

Ambient conditions:

0 - 45 º C
0 - 80 % relative humidity
(non-condensing)

Power supply:

9 V pack; ca. 100 operating hours

Housing:

ABS plastic housing

Dimensions:

165  x  95  x 42  mm (LxBxH)

Weight:

ca. 280 g (without electrode)

Certified:

CE

Cat. No.:

418 819

Temperature
Compensation:

0 - 100

°

C, manual

Summary of Contents for SensoDirect CD 19

Page 1: ...SensoDirect CD 19 Operating Instructions Conductivity Meter CAL 0 4 6 10 2 8 C 0 40 60 100 20 80 GB...

Page 2: ...ares that this product Product name SensoDirect CD 19 with all optional items conforms to the following regulations EMC EN 61326 1997 A1 1998 A2 2001 EN 55022 Class B 1998 The product conforms to the...

Page 3: ...description 4 2 Products supplied 4 3 Setting to work 4 4 Calibration 4 5 Carrying out measurements 5 6 Overhaul and maintenance 6 7 Changing the battery 6 8 Spare parts accessories 6 9 Technical data...

Page 4: ...trode carrying case operating instructions 3 Setting to work The unit is supplied as standard with a battery and is therefore ready for immediate use once the cinch connector plug to the pH electrode...

Page 5: ...specification adjustments in the factory are made using a 0 05 molecular KCl solution at a temperature of 25 C 6 7 mS cm 5 Carrying out measurements First of all determine the temperature of the medi...

Page 6: ...h any water repellent substances oils greases silicones 7 Changing the Battery If BAT appears in the bottom left corner of the display the battery is flat and must be replaced Remove the back of the u...

Page 7: ...e PETP shaft Electrode material graphite Ambient conditions 0 45 C 0 80 relative humidity non condensing Power supply 9 V pack ca 100 operating hours Housing ABS plastic housing Dimensions 165 x 95 x...

Page 8: ...cm Resolution 0 01 mS cm Accuaracy 2 5 F S 1 Digit Instrument Ambient 0 45 C Conditions 0 80 rel humidity no condensing Sample Conditions 0 80 C Battery 9 V IEC 6F22 CE 89 336 EN add Tolerance 1 Sens...

Page 9: ...ve 6 screws 9 V Replace 9 V Battery Typ IEC 6F22 Don t touch LOW BAT Display Remove battery if instrument is unused for a long time Clean Deionized Water Dry CAL Adjust mS cm 6 70 Display 0 05 mol l K...

Page 10: ...torage batteries is not subject to incorrect use or maintenance negligence or other causes other than those due to material or production faults 2 the unit is returned accompanied by a full descriptio...

Page 11: ...alongside the legal warranty rights of the end user and is not affected if his contract is with a third party Proof of warranty Proof of purchase is required as entitlement to claim under warranty If...

Page 12: ...e 12 D 44287 Dortmund Tel 49 0 2 31 9 45 10 755 Fax 49 0 2 31 9 45 10 750 sales aqualytic de www aqualytic de Germany Technical changes without notice Printed in Germany 08 04 QM System Certificate No...

Reviews: