Aqualytic SensoDirect CD 19 Operating Instructions Manual Download Page 11

11

be repaired or remedied using spare parts of the ap-
propriate quality, free of charge.

Further claims, in particular for compensation for dam-
age not affecting the unit itself, are excluded.

The manufacturers warranty exists alongside the legal
warranty rights of the end user and is not affected if
his contract is with a third party.

Proof of warranty

Proof of purchase is required as entitlement to claim
under warranty. If relevant paperwork is not submitted
the repairs will be chargeable at the service prices
pertaining at the time of repair.

Please return the unit complete with its packaging, full
description of defect and purchase receipt.

Summary of Contents for SensoDirect CD 19

Page 1: ...SensoDirect CD 19 Operating Instructions Conductivity Meter CAL 0 4 6 10 2 8 C 0 40 60 100 20 80 GB...

Page 2: ...ares that this product Product name SensoDirect CD 19 with all optional items conforms to the following regulations EMC EN 61326 1997 A1 1998 A2 2001 EN 55022 Class B 1998 The product conforms to the...

Page 3: ...description 4 2 Products supplied 4 3 Setting to work 4 4 Calibration 4 5 Carrying out measurements 5 6 Overhaul and maintenance 6 7 Changing the battery 6 8 Spare parts accessories 6 9 Technical data...

Page 4: ...trode carrying case operating instructions 3 Setting to work The unit is supplied as standard with a battery and is therefore ready for immediate use once the cinch connector plug to the pH electrode...

Page 5: ...specification adjustments in the factory are made using a 0 05 molecular KCl solution at a temperature of 25 C 6 7 mS cm 5 Carrying out measurements First of all determine the temperature of the medi...

Page 6: ...h any water repellent substances oils greases silicones 7 Changing the Battery If BAT appears in the bottom left corner of the display the battery is flat and must be replaced Remove the back of the u...

Page 7: ...e PETP shaft Electrode material graphite Ambient conditions 0 45 C 0 80 relative humidity non condensing Power supply 9 V pack ca 100 operating hours Housing ABS plastic housing Dimensions 165 x 95 x...

Page 8: ...cm Resolution 0 01 mS cm Accuaracy 2 5 F S 1 Digit Instrument Ambient 0 45 C Conditions 0 80 rel humidity no condensing Sample Conditions 0 80 C Battery 9 V IEC 6F22 CE 89 336 EN add Tolerance 1 Sens...

Page 9: ...ve 6 screws 9 V Replace 9 V Battery Typ IEC 6F22 Don t touch LOW BAT Display Remove battery if instrument is unused for a long time Clean Deionized Water Dry CAL Adjust mS cm 6 70 Display 0 05 mol l K...

Page 10: ...torage batteries is not subject to incorrect use or maintenance negligence or other causes other than those due to material or production faults 2 the unit is returned accompanied by a full descriptio...

Page 11: ...alongside the legal warranty rights of the end user and is not affected if his contract is with a third party Proof of warranty Proof of purchase is required as entitlement to claim under warranty If...

Page 12: ...e 12 D 44287 Dortmund Tel 49 0 2 31 9 45 10 755 Fax 49 0 2 31 9 45 10 750 sales aqualytic de www aqualytic de Germany Technical changes without notice Printed in Germany 08 04 QM System Certificate No...