Thank you for purchasing Aqualogic

s Hydromate20. Following these guidelines will help 

you to get the most from your product.

 

Hydromate Installation 

 

 

Before  commencing,  if  possible  fill  and  flush  the  cistern,  then  isolate  the  water     

supply. This will help when it comes to setup.

 

 

1.

 

Locate a section of the cistern supply pipe work that will accept the solenoid 

valve. 

 

2.

 

Decide on a location to site the Hydromate control box. Ideally this should be in 

a position that ensures occupancy detection for the urinals only. The effective  

sensing angle is up to 30˚ and the range up to 5 metres. The distance between 

control box and solenoid valve can be up to 30 metres.

 

3.

 

Locate the stopcock/service valve for the water supply to the cistern and isolate.

 

4.

 

Install the solenoid valve(s) (observing the correct direction of flow marked on 

the valve body).       

 

5.

 

Make cable entry holes in back box and fit suitable cable glands if required.

 

6.

 

Mount the control back box in the desired position. 

 

7.

 

Prepare the 3 core flex between the valve and control box, leaving surplus at 

each end for connection.

 

8.

 

Disassemble the solenoid valve plug and using the 3 core flex and make connec-

tion between the valve plug and the terminal block marked 

valve

’.             

Note: The valve will work in either polarity.  

 

9.

 

The Hydromate 20 can operate up to 3 solenoid valves. A suitable junction box 

will be required if installing multiple valves.

   

 

 

 

10.

 

Before connecting the 230v supply cable ensure a safe isolation procedure has 

been followed*. 

 

11.

 

NB: (*The electrical supply connections for this unit should only be carried out 

by a competent and qualified electrician)

 

12.

 

Reinstate water supply and test for leaks. 

 

Hydromate 20 Features Explained

 

Flush  Frequency

.  Set  on  Flush  Program  1,  the  urinal  will  flush  30  minutes  after     

detecting the first user. Set on Flush Program 2,  it will flush  40 mins after  detecting 

first user.  This can be altered at any time after set up.

 

Hygiene  Flush. 

During periods of non occupancy the unit will perform a hygiene flush 

every 24, 48 or 72 hours depending on program selected

 

Reset. 

A reset button is located within the Hydromate this clears the memory ready  

for reprogramming.

 

Lighting Control. 

Upon detection the washroom lighting will remain on for a set time

 