Aqualisa Visage Q Series User Manual Download Page 16

aqualisa.co.uk

Please note that calls may be recorded for training and quality purposes.

The company reserves the right to alter, change or modify the product specifications without prior warning.

® Registered Trademark Aqualisa Products Limited.

Q5097  Part No 705247  Issue 01 Jun 20

THE FLYERS WAY, WESTERHAM, KENT TN16 1DE

Customer Services: 01959 560010

REPUBLIC OF IRELAND

Sales enquiries: 01-864-3363, Service enquiries: 01-844-3212

Summary of Contents for Visage Q Series

Page 1: ...VISAGE and VISAGE SMART USER GUIDE...

Page 2: ...lation of your product refer to the Smart Installation Guide Declaration of Conformity Aqualisa Products Limited declares that the Aqualisa SmartValve and supplied controller in conjunction with pairi...

Page 3: ...tion analysis to enhanced user functions Keep up to date with latest features for the Aqualisa app and voice activation by visiting the Aqualisa website Download and open the free Aqualisa app Find in...

Page 4: ...ature has been reached When the LED display is constant your shower is ready to use 5 Press the Start Stop button on the controller to turn the shower off TEMPERATURE START STOP Adjust before starting...

Page 5: ...LET TEMPERATURE START STOP Push and hold for over 3 seconds and release when flow switches between outlets As a safety feature the Aqualisa SmartValve has a maximum run time of 20 minutes The flow can...

Page 6: ...void water dripping from the shower head after use we advise to tilt the head back to allow residual water to drain out The above recommendation applies to both adjustable and fixed shower heads 4 Eco...

Page 7: ...holder to move up or down the rail 3 Angular adjustment is made by carefully but firmly pulling forwards or pushing back the shower head against the ratchet in the holder Removing the shower head Depr...

Page 8: ...r again to disengage the plug Bath Overflow Filler Do not leave the bath filler running unattended Although the overflow will remove excess water once the bath is overfilled this may not be sufficient...

Page 9: ...me out if unable to connect Before starting you will need your Network Name SSID code and password as they are required during the Aqualisa app setup journey These can normally be found on your intern...

Page 10: ...connection A successful connection message will also be provided in the Aqualisa app journey indicating that the shower is ready for use If connection is unsuccessful a message will appear in your Aq...

Page 11: ...procedure should be completed regularly as often as once a week in some hard water areas as scale build up can affect the spray pattern and cause the shower to perform poorly Failure to descale the sh...

Page 12: ...water starts to flow and increase in volume gradually turn up the temperature If the flow starts to splutter stop moving the temperature control until the flow again stabilises then continue to move t...

Page 13: ...mperature Incorrect setting on Logic Module of Aqualisa SmartValveTM If hot water supply is from a combination boiler the Logic module mode MUST be set to COMBI Refer to Setting Water System Mode sect...

Page 14: ...warms the stored water Check by running a cold tap that is supplied from the water storage N B Kitchen taps are normally fed from the mains water system Maximumtemperature settingisnottoyour preferenc...

Page 15: ...vent that something goes wrong we want all our customers to be protected which is why we give you a totally free of charge 1 year parts and labour guarantee You can easily increase your FREE guarantee...

Page 16: ...right to alter change or modify the product specifications without prior warning Registered Trademark Aqualisa Products Limited Q5097 Part No 705247 Issue 01 Jun 20 THE FLYERS WAY WESTERHAM KENT TN16...