Eccentric elbows are provided to allow for inlet pipework adjustment between 130mm – 170mm
centres. Construct suitable connections terminating in ½” BSP female fittings.
•
i
When using the eccentric elbows provided we recommend leaving sufficient threads from the
finished wall surface, after the cover plates have been fitted, to ensure adequate purchase
for the exposed valve. If using alternative fixings please refer to the installation instructions
provided to ensure adequate threads are left to connect the valve after the cover plates have
been fitted to the finished wall surface. Please refer to page 14 for recommended thread depths
information.
20
•
i
In addition to the guide below it is essential that the written instructions are read and
understood and that you have all the necessary components before commencing installation.
Failure to install the product in accordance with these instructions may adversely affect the
warranty terms and conditions. Do not undertake any part of this installation unless you are
competent to do so. Prior to starting ensure that you are familiar with the necessary plumbing
regulations required to install the product correctly and safely.
The BAR001FIX bar valve fixing kit provided with Midas
110/220 shower column provides a method of surface siting
exposed bar valves onto a finished wall surface, using
15mm concealed pipe work.
If required, fit the bar valve fixing accessory following the relevant installation instructions
provided and proceed to step 6.
The valve and fixing bracket assembly MUST NOT be used as a grab rail support method.
INSTALLATION INSTRUCTIONS
Bar valve fixing accessories are available separately. The
MD300EFB is a first fix fixing bracket. If using the
MD300EFB bracket, ensure sufficient threads are left
from the finished wall surface, after the cover plates have been fitted, to ensure adequate
purchase for the valve. Please refer to page 14 for recommended thread depths information.
•
i
A MINIMUM CLEARANCE OF 1.2M FROM THE TOP OF THE SHOWER
VALVE IS REQUIRED TO INSTALL THE SHOWER COLUMN
.
Summary of Contents for MIDAS 110
Page 1: ...MIDAS Installation instructions 110 220 ...
Page 10: ...TYPICAL THERMAL STORAGE UNIT SYSTEM INSTALLATION suitable for use with all Midas valves 10 ...
Page 11: ...MIDAS COMPONENTS Midas 110 shower Midas 110 shower column Midas 110 bath shower mixer 11 ...
Page 12: ...MIDAS COMPONENTS Midas 220 shower Midas 220 shower column Midas 220 bath shower mixer 12 ...
Page 34: ...NOTES 34 ...