Installation instructions

iSys Digital remote control

In addition to the guide below it is essential that the written

instructions below are read and understood and that you have all

the necessary components (shown overleaf) before commencing

installation. Failure to install the product in accordance with these

instructions may adversely affect the warranty terms and

conditions. Do not undertake any part of this installation unless you

are competent to do so. Prior to starting, ensure that you are

familiar with the necessary plumbing regulations required to install

the product correctly and safely.

THE DIGITAL PROCESSOR MUST BE ISOLATED FROM THE MAINS

POWER SUPPLY PRIOR TO INSTALLING THE ISYS DIGITAL REMOTE

CONTROL.

!

For use with single outlet iSys Digital shower systems

IF FITTING THIS PRODUCT WITH AN ISYS DIGITAL SINGLE

OUTLET SHOWER SYSTEM, PLEASE FOLLOW THE FITTING

INSTRUCTIONS BELOW.

!

Summary of Contents for iSys ISD.B3.DS.14

Page 1: ...iSys Digital remote control installation instructions Page 1 iSys Digital Remote control Installation guide TM...

Page 2: ...iSys Digital remote control ISD B3 DS 14 iSys Digital remote control installation instructions Page 2 iSys Digital remote control...

Page 3: ...iSys Digital remote control installation instructions Page 3 Literature not shown Components...

Page 4: ...subjected to continuous spray or it can be sited outside the showering area up to 10 metres from the Digital processor The iSys Digital remote control is not suitable for use with any other Aqualisa D...

Page 5: ...uctions may adversely affect the warranty terms and conditions Do not undertake any part of this installation unless you are competent to do so Prior to starting ensure that you are familiar with the...

Page 6: ...6mm hole for the data cable entry point The cable entry point should be made in the top right hand corner of the back plate recess to ensure the two holes are kept separate 1 Wiring diagram 10m Data C...

Page 7: ...Digital remote control installation instructions Page 7 Prepare a suitable route and install the 10m low voltage data cable leaving a working end of at least 70mm including the connector plug The end...

Page 8: ...late assembly and lower the button into position 6 To release the button insert a small flat bladed screw driver into the small slot at the bottom of the button assembly to release the locking clip ta...

Page 9: ...rt system the cable plugs into the diverter using the splitter box provided If using with a Divert product refer to the Digital Divert instructions opposite Prior to commissioning the iSys Digital rem...

Page 10: ...iSys Digital remote control installation instructions Page 10 10m Data Cable 10m Data Cable Splitter box 2m Data Cable Wiring diagram...

Page 11: ...rews of a suitable length not included 2 Prepare a suitable route and install the 10m low voltage data cable leaving a working end of at least 70mm including the connector plug The end of the data cab...

Page 12: ...ight seal making sure the seal is no longer visible 5 Locate the slot at the top of the button assembly onto the locating peg at the top of the back plate assembly and lower the button into position 6...

Page 13: ...the button out and up off of the back plate top locating peg BEFORE ANY ELECTRICAL ADJUSTMENT IS ATTEMPTED THE ELECTRICITY SUPPLY MUST BE TURNED OFF AT THE MAINS SWITCH ELECTRICAL INSTALLATION MAY ONL...

Page 14: ...er junction box as shown 11 PLEASE NOTE THE 10M LOW VOLTAGE DATA CABLES CAN BE PLUGGED INTO EITHER OF THE SIDE BY SIDE ENTRY PORTS OF THE SPLITTER JUNCTION BOX THIS WILL NOT AFFECT THE OPERATION OF TH...

Page 15: ...enquiries aqualisa co uk Republic of Ireland Sales enquiries 01 864 3363 Service enquiries 01 844 3212 Part No 700982 Issue 01 Jan 14 Please note that calls may be recorded for training and quality p...

Reviews: