Dream DCV cartridge replacement
! Isolate both hot and cold water supplies.
1. Remove the grub screw cover located at the 6 o’clock position.
2. Insert the hexagonal key into the temperature control knob
and loosen the grub screw. Remove the control knob from the
valve and set aside.
3. Carefully remove the white plastic maximum temperature stop ring from the brass
spindle using a small flat bladed screwdriver and set aside.
4. Remove the thermostatic cartridge by unscrewing anti-clockwise from the valve, using
a 30mm socket or wrench.
5. Screw the new cartridge into the body assembly, and tighten using a 30mm socket
or wrench.
6. Adjust the temperature by turning the brass spindle clockwise for a cooler setting or
anti-clockwise for a warmer setting.
!Please note: The factory setting is set to 46˚C. This is marked with a red marking on
the brass spindle. When the marking is a the 12 o’clock position, the temperature
is set to 46˚C.
24
!If the lever is fitted onto the bottom of the knob, unscrew the lever and
remove the securing grub screw using the hexagonal key provided.