background image

4.2.6 Timer setting

You can set the timer of unit on
In the on or off state, Press "TIME ON" to enter timer-on interface

Press "TIME ON" and 

time-hour-bit flashing

Press "     " or "       " to change the hours value

Press "TIME ON"  

to save hours At the same time,  minutes-bit flashing Press "       " or  "       " to  change the 
minute value

Press "TIME ON" to save and exit. At this time,  "TIME ON" LED light is 

on. ( The time-off setting is to press "TIME OFF", the  other operation is the same as 
timer-on )
For example

MODE

HEAT

COOL

CLOCK

TIMER ON TIMER OFF

AUTO

MODE

HEAT

COOL

CLOCK

TIMER ON TIMER OFF

Hour

Munite

Press

TIME ON

MODE

HEAT

COOL

CLOCK

TIMER ON TIMER OFF

MODE

HEAT

COOL

CLOCK

TIMER ON TIMER OFF

Press

       

or

       

MODE

HEAT

COOL

CLOCK

TIMER ON TIMER OFF

MODE

HEAT

COOL

CLOCK TIMER ON TIMER OFF

MODE

HEAT

COOL

CLOCK

TIMER ON TIMER OFF

(1)

AUTO

AUTO

AUTO

AUTO

AUTO

AUTO

Press

TIME ON

Press

TIME ON

Press

       

or

       

Press

TIME ON

16

4. USAGE AND OPERATION

Summary of Contents for SF010P G/Evap

Page 1: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual ...

Page 2: ......

Page 3: ...mming Pool Heat Pumps Location 3 3 How Close to Your Pool 3 4 Swimming Pool Heat Pumps Plumbing 3 5 Swimming Pool Heat Pumps Electrical Wiring 3 6 Initial Start up of the Unit 4 Usage and Operation 4 1 Function of the controller 4 2 Usage of the controller 4 3 5 Maintenance and Inspection 5 1 Maintenance 5 2 Parameter table Malfunction table 6 Appendix 1 3 3 5 8 8 9 9 10 11 11 12 12 13 19 20 20 20...

Page 4: ...ated inside the unit is equipped with an over load protection system It does not allow for the unit to start for at least 3 minutes from a previous stoppage 10 The unit can only be repaired by the qualified personnel of an installer center or an authorized dealer for North America market 11 Installation must be performed in accordance with the NEC CEC by authorized person only for North America ma...

Page 5: ...and frequency as stated in this manual Use genuine standard spare parts only Failure to comply with these recommendations will invalidate the warranty Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature constant For split type unit The indoor unit can be Discretely hidden or semi hidden to suit a luxury house Our heat pump has following characteristics 1 Durable Th...

Page 6: ...ntal 47 50 1 5 4 UNIT Heating capacity Heating Power Input Running Current Power Supply Compressor Quantity Compressor Fan Quantity Fan Power Input Fan Rotate Speed Fan Direction Noise Water Connection Water Flow Volume Water Pressure Drop max Unit Net Dimensions L W H Unit Ship Dimensions L W H Net Weight Shipping Weight kW Btu h kW A W RPM dB A mm 3 m h kPa mm mm kg kg See the drawing of the uni...

Page 7: ...e see nameplate see package label SF050P G Evap 22 75000 3 6 16 1 230V 50Hz 1 scroll 2 120 2 850 horizontal 56 50 7 5 20 SF050 3P G Evap 22 75000 3 6 7 3 380V 3N 50Hz 1 scroll 2 120 2 850 horizontal 56 50 7 5 20 UNIT Heating capacity Heating Power Input Running Current Power Supply Compressor Quantity Compressor Fan Quantity Fan Power Input Fan Rotate Speed Fan Direction Noise Water Connection Wat...

Page 8: ...ion 264 290 91 300 Water inlet 50 Water outlet 50 570 746 395 280 5 2 SPECIFICATION 2 2 The dimensions for Swimming Pool Heat Pump Unit unit mm Model SF015P G Evap Horizontal vision Vertical vision 264 290 91 300 Water inlet 50 Water outlet 50 570 746 395 280 ...

Page 9: ... inlet 50 Water outlet 50 Horizontal vision Vertical vision 372 956 2 2 The dimensions for Swimming Pool Heat Pump Unit 2 SPECIFICATION Models SF020P G Evap unit mm 334 98 545 360 600 350 Water inlet 50 Water outlet 50 Horizontal vision Vertical vision 372 956 ...

Page 10: ...or Swimming Pool Heat Pump Unit 2 SPECIFICATION 7 Model SF050P G Evap SF050 3P G Evap SF060P G Evap SF060 3P G Evap unit mm 455 430 630 Water Outlet 50 103 400 Water Inlet 50 1251 1002 396 Horizontal vision Vertical vision ...

Page 11: ...ller 3 1 Installation illustration Attention Please follow these steps when using for the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valve and start the unit ATTN It is necessary that the water in pipe is higher than the pool surface Chlorinator cell Water outlet Pool Valve Water supply Water inlet Water pump San...

Page 12: ... and may prevent adequate heat delivery 3 2 Swimming Pool Heat Pumps Location Normally the pool heat pump is installed within 7 5 metres of the pool The longer the distance from the pool the greater the heat loss from the piping For the most part the piping is buried Therefore the heat loss is minimal for runs of up to15 meters 15 meters to and from the pump 30 meters total unless the ground is we...

Page 13: ...according to the nameplate The water pressure drop is less than 10kPa at max Flow rate Since there is no residual heat or flame Temperatures The unit does not need copper heat sink piping PVC pipe can be run straight into the unit Condensation Since the Heat pump cools down the air about 4 5 water may condense on the fins of the horseshoe shaped evaporator If the relative humidity is very high thi...

Page 14: ... Time Delay The unit is equipped with a 3 minute built in solid state restart delay included to protect control circuit components and to eliminate restart cycling and contactor chatter This time delay will automatically restart the unit approximately 3 minutes after each control circuit interruption Even a brief power interruption will activate the solid state 3 minute restart delay and prevent t...

Page 15: ...p Down Auto indicator light Heating indicator light Cooling indicator light Timer on indicator Timer off indicator Key Key name Key function 4 1 Function of wire controller LED display Press this key to select the upward option or increase the parameter value Press this key to select the downward option or decrease the parameter value Choose key Press this key to choose the Celsius degree or Fahre...

Page 16: ...can choose unit mode In the unit on or off state you can choose cooling heating or a mode by pressing MODE button Attention if the unit is only for heating cooling the mode switching operation is invalid utomatic Cooling temp Cooling indicator light Heating temp Heating indicator light Press MODE 4 2 Usage of wire controller 4 2 3Temperature selection Choose display type of unit temperature when t...

Page 17: ...Press can not save setting parameter but back to the main interface Attention If there is no operation for 5s system would remember parameter setting and back to the main interface MODE HEAT COOL TIMERON TIMEROFF MODE HEAT COOL CLOCK TIMERON TIMEROFF Running interface MODE HEAT COOL CLOCK TIMERON TIMEROFF AUTO AUTO AUTO CLOCK Press or Cooling set Press MODE Save parameter Press System will save us...

Page 18: ...setting parameter and back to main interface Attention If there is no operation for 5s system will remember parameter setting and back to the main interface MODE HEAT COOL CLOCK TIMERON TIMEROFF AUTO MODE HEAT COOL CLOCK TIMERON TIMEROFF Press CLOCK MODE HEAT COOL CLOCK TIMERON TIMEROFF MODE HEAT COOL CLOCK TIMERON TIMEROFF Press or MODE HEAT COOL CLOCK TIMERON TIMEROFF MODE HEAT COOL CLOCK TIMERO...

Page 19: ...me TIME ON LED light is on The time off setting is to press TIME OFF the other operation is the same as timer on For example MODE HEAT COOL CLOCK TIMERON TIMEROFF AUTO MODE HEAT COOL CLOCK TIMERON TIMEROFF Hour Munite Press TIME ON MODE HEAT COOL CLOCK TIMERON TIMEROFF MODE HEAT COOL CLOCK TIMERON TIMEROFF Press or MODE HEAT COOL CLOCK TIMERON TIMEROFF MODE HEAT COOL CLOCK TIMERON TIMEROFF MODE HE...

Page 20: ... timer off light turn off 2 MODE HEAT COOL CLOCK TIMERON TIMEROFF AUTO MODE HEAT COOL CLOCK TIMERON TIMEROFF Press TIME ON MODE HEAT COOL CLOCK TIMERON TIMEROFF Press On Off AUTO AUTO 4 2 7 Keyboard lock To avoid mis operations please lock the controller after parameter setting At the main interface pressing for 5 seconds when hearing one sound the keyboard is locked When the keyboard is locked pr...

Page 21: ...showing on the controller screen when relative malfunction occurs You can refer to the malfunction table to find out the failure cause and solution For example MODE HEAT COOL CLOCK TIMERON TIMEROFF AUTO Water inlet temp Sensor failure 18 4 USAGE AND OPERATION ...

Page 22: ...ode default Adjust yes no Adjustable 27 4 3 Parameter table Adjustable Adjustable T02 True testing figure Inlet water temp Outlet water temp Return water temp Setting auto mode R02 R03 T03 T04 T05 T01 Pipe temp Ambient temp Evaporator temp 27 True testing figure True testing figure True testing figure True testing figure ...

Page 23: ...temp Sensor failure Display P04 P01 P02 P05 P07 Canse The ambient temp sensor is open or shortcircuit The water inlet temp Sensor is open or shortcircuit The water outlet temp sensor is open or shortcircuit The pipe temp sensor is open or short circuit The evaporator temp Sensor is open or shortcircuit Solution Check or change the ambient temp Sensor Check or change thewater inlet temp Sensor Chec...

Page 24: ... Water pump 220 230VAC OUT4 High speed of fan motor 220 230VAC OUT3 OUT1 No Symbol Meaning 4way valve 220 230VAC Compressor of system1 220 230VAC NET GND 12V Wire controller DI01 GND On Off Switch input no use No use Flow switch input normal close 7 8 9 10 11 12 14 15 High pressure protect Low pressure protect 5 Neutral wire AC N OUT5 Low speed of fan motor 220 230VAC 6 16 AI01 GND AI02 GND AI03 G...

Page 25: ...e line MCB Creepage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 16mm 2 mm 25 2 mm 25 2 35mm 2 50mm 2 70mm 2 95mm 2 Three phase unit 2 3 1 5mm 2 3 2 5mm 2 3 4mm 2 3 6mm 2 3 10mm 2 16mm 3 2 25mm 3 2 3 25mm 2 3 35mm 2 3 50mm 2 3 70mm 2 3 95mm 30mA less than 0 1 sec 30mA...

Page 26: ...Note ...

Page 27: ......

Page 28: ...EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling ...