background image

XE

 

MOBILE

 

SERIES

AQU

AFOG

11

Jaybird Mfg., Inc.

65

59

372

351

60

61

71

423

75

72

72

65

65

143

143

65

65

67

65

Tank's W

all

 

Inside T

ank

 

93

94

677

hrSM-exp t

ank

 e

xploded

 v

iew

 

Wall

 

Inside T

ank

 

Unit's 25' P

ower 

Line fr

om Mo

tor

400-132

400-036

35

400-088

(Optional)

449

483

STO-14/3

455

290

298

295

READ &

UNDERS

TAND

NOTICE

WARNING

MAINT

AIN A 

FULL T

ANK TO 

RET

AIN EXPL

OSION-PR

OOF FEA

TURES!

OPERA

TE ONL

Y WHEN T

ANK IS FILLED

 

AND UNIT IS CONNECTED TO A

RELIABLE W

ATER SOUR

CE.

WARNING

KEEP HANDS 

CLEAR!

HIGH-SPEED W

ARNING. MAKE SURE 

GUARDS ARE INST

ALLED OR UNIT IS OUT 

OF REA

CH.

DANGER

ALL WIRING AND 

ELECTRIC

AL 

CONNECTIONS MUS

T BE PERF

ORMED B

A QU

ALIFIED ELECTRICIAN

.

96

Summary of Contents for XE-HRSM-2000-EXP

Page 1: ...ead Understand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL UL and CSA Electrical Components NOTICE MODEL XE HRSM 2000 EXP ON OFF Rear Feed...

Page 2: ...OR SERIOUS INJURY WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN DEATH OR SERIOUS INJURY CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVO...

Page 3: ...ll fasteners at frequent intervals for proper tightness MOTORS ELECTRICAL EQUIPMENT AND CONTROLS CAN CAUSE ELECTRICAL ARCS THAT WILL IGNITE FLAMMABLE LIQUID OR GAS NEVER OPERATE OR REPAIR IN OR NEAR F...

Page 4: ...TENSION CORD IS NOT RECOMMENDED IF NECESSARY REFER TO FIG 12 NOTICE Grounded and suitable for hazardous duty locations Unit Preparation EXTENSION CORD SPECIFICATIONS FOR SINGLE FAN USE ONLY AWG Americ...

Page 5: ...Liquid Supply Hose Connection Liquid Storage Atomized Liquid 449 20A Dedicated Power Supply The volume of fog can be regulated by adjusting the Flow Control Valve See Fig 2 Particle size is smaller dr...

Page 6: ...n on the unit and listen for any possible abnormalities such as the blades rubbing against the venturi Make re adjustments if necessary Evaluatefogqualitybyadjustingtheoutputusingtheflowcontrolvalve S...

Page 7: ...pump remove the inline strainer cap Part 71 and turn the system ON for a few seconds Replace cap and try operating unit again B If pump is receiving electricity but there is no fog check for sediment...

Page 8: ...the electrical breaker trips off there is an overload in the system and there may be a serious motor problem Turn off all other devices connected to the same circuit If the breaker continues to trip...

Page 9: ...lt SST 8 288 1 8 NPT F elbow 1 294 1 8 NPT M x 3 8 tube fitting 1 349 5 16 brass rod 1 391 Top pivot plate 1 392 Bottom pivot plate 1 395 5 16 nylon lock nut 2 400 047 XE Faceplate screw SST 8 403 Bra...

Page 10: ...plate Rear of Housing 16 52 600 L 117 54 20 49 32 32 20 600 R 10 Top of Tank Power Cord 58 56 58 57 56 57 116 391 392 56 517 395 479 Side view of motor 458 459 460 452 454 458 457 453 10 2002 10 2002...

Page 11: ...14 3 455 290 298 295 REA D UNDER ST AND NOTICE WAR NING MA INT AIN A FU LL TANK TO RE TAIN EX PL OS ION PR OO F FE ATUR ES OP ER AT E ON LY WH EN TA NK IS FIL LE D AN D UN IT IS CO NN EC TE D TO A RE...

Page 12: ...4 20 finish nut SST 2 288 1 8 NPT elbow 1 290 1 4 NPT street tee 1 294 1 8 NPT F x 3 8 tube fitting 1 295 1 4 NPT M x 1 4 tube fitting 1 297 1 4 NPT F x 3 8 tube fitting 1 298 1 2 NPT M x 1 4 NPT F bu...

Page 13: ...r will be required 4 Inspect Blade Assembly Clean the blade assembly about once a year especially if a film of calcium or mineral deposits is visible on the exterior of the blades Remove any build up...

Page 14: ...ck of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUFACTURI...

Reviews: