Aquafog HRSM-1500 User'S Manual And Operating Instructions Download Page 3

3

10.  Keep fingers away from a running unit; 

        fast moving and hot parts will cause injury 

        and/or burns.
11.  If the equipment starts to vibrate abnormally, 

        STOP the motor and check immediately for 

        the cause. Vibration is generally an indication 
        of trouble.

Fogging Precautions

DANGER

A motionless atomizer may 

appear safe, but its blade 

could suddenly begin high-

speed rotation without 

warning as a result of 

control programming.

When the HRSM is automated by controls, 

warning signs should be posted near the high-

speed equipment.

Disconnect and lock out power source to inspect 

or service the unit.

G

ENERAL

 S

AFETY

Since the mobile HRSM uses high-speed 

components to atomize liquids, the following safety 

precautions must be observed at all times:

1.  Read all manuals included 

     with this product. Be familiar 

     with the product and controls.
2.  The HRSM is intended to be 

     used on level ground. Test for stability before 

     operation.
3.  Follow United States Environmental Protection 

     Agency (EPA) guidelines and regulations when 

     fogging pesticide or chemical solutions.
4.  Follow all local electrical and safety codes 

     as well as the United States National  

 

     Electrical Codes (NEC) and Occupational  Safety  

     and Health Act (OSHA).
5.  Only persons well acquainted with these 

     rules of safe operation should be allowed to 

     use the atomizer.
6.  Keep visitors away and NEVER allow children in 

     the work area.
7.  Use of an extension cord for the HRSM is 

     not recommended. If necessary, refer to 

     the A.W.G  chart in the following section or 

     consult a  certified electrician.
8.  Before each use, inspect blade assembly 

     and electrical components for signs of damage, 

     deterioration, weakness or leakage. Repair or 

     replace defective items before using.
9.  Check all fasteners at frequent intervals for 

     proper tightness.

MOTORS, ELECTRICAL EQUIPMENT AND 

CONTROLS CAN CAUSE ELECTRICAL 

ARCS THAT WILL IGNITE FLAMMABLE 

LIQUID OR GAS. NEVER OPERATE OR 

REPAIR IN OR NEAR FLAMMABLE LIQUID OR GAS. 

NEVER STORE FLAMMABLE LIQUIDS OR GASES IN THE 

VICINITY OF THE ATOMIZER.

DO NOT ATOMIZE

FLAMMABLE MATERIALS.

12.  Humidity and cold air are

        two common asthma triggers.    

 

        Asthmatic people working  

 

 

        with this equipment need to

        be made aware of the risk.
13.  When atomizing toxic chemicals, follow  the  

        instructions provided by the chemical    

        manufacturer.

NEVER OPERATE HRSM 

WITHOUT THE SAFETY GUARD 

IN PLACE UNLESS THE UNIT IS RAISED SEVEN FEET 

ABOVE WORKING HEIGHT.

WARNING

WARNING

DANGER

HIGH-SPEED ROTATION

Summary of Contents for HRSM-1500

Page 1: ...MODEL o HRSM 2000 o HRSM 2001 3ph o HRSM 1500 Read Understand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL UL and CSA Electrical Components...

Page 2: ...TH OR SERIOUS INJURY WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN DEATH OR SERIOUS INJURY CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT A...

Page 3: ...nited States National Electrical Codes NEC and Occupational Safety and Health Act OSHA 5 Only persons well acquainted with these rules of safe operation should be allowed to use the atomizer 6 Keep vi...

Page 4: ...E ONLY AWG American Wire Gauge Voltage 25 to 50 ft 50 to 100 ft 115 14 AWG 12 AWG 230 16 AWG 14 AWG Fig 12 ELECTRICAL GROUND FAULT RECEPTACLES ARE RECOMMENDED AND MAY BE REQUIRED BY LOCAL AND OR NATIO...

Page 5: ...ith 15 intervals up to 45 Propelling the fog upward allows more time for the particles to evaporate keeping floor areas drier When making an adjustment balance the weight of the fogging head off of th...

Page 6: ...alities such as the blades rubbing against the venturi Make re adjustments if necessary Evaluate fog quality adjusting the output by using the flow control valve See Fig 3 After starting it generally...

Page 7: ...the handle is down and closed when up If the valve is open and there is still no fog the pump may need to be primed In rare cases the pump may retain an air bubble To prime the pump remove the inline...

Page 8: ...circuit If the breaker continues to trip the motor is probably in need of repair Consult an electrician for evaluation 9 Fan and or Motor Vibration A If the fan unit begins vibrating severely first be...

Page 9: ...1 41 10 24 x 1 2 phillips RH SST 4 42 10 24 nylon stop nut SST 4 43 11 16 x 1 1 4 flat washer SST 1 44 Drain tubing 3 45 Liquid tight cord fitting 2 46 Key 1 52 1 4 20 x 3 4 HH bolt SST 4 54 1 4 20 x...

Page 10: ...w of motor Side of top pivot plate Rear of Housing Power supply in from on off switch Power supply out to pump 8 13 14 15 16 52 600 L 117 54 20 344 46 58 56 45 45 43 8 39 44 32 58 57 56 57 116 349 403...

Page 11: ...65 59 372 76 82 85 86 86 92 89 88 87 351 60 61 84 109 45 110 71 69 75 72 72 65 65 143 143 65 65 84 45 198 67 65 Tank s Wall Inside Tank 93 94 96 677 Three Phase Components Single Phase Components HRS...

Page 12: ...Electrical switch box 3 phase 1 88 Switch 3 phase 1 89 Spacer plate 3 phase 1 92 Switch cover 3 phase 1 93 Hose connector gasket 1 94 Hose connector 1 96 Gasket 1 97 Float valve 1 98 Stem 1 99 Float...

Page 13: ...ray oil around the shaft where it exits the motor body Lubricate motor once a season or whenever squealing occurs 4 Inspect Blade Assembly Clean the blade assembly about once a year especially if a fi...

Page 14: ......

Reviews: