13
M
AINTENANCE
1. Clean Strainers
The RSM is equipped with 3 strainers that should be cleaned periodically - the Drain
Strainer (Part #39) in the Tank, the Inline Strainer (Part #71) at the bottom of the
Flow Control Valve and the Pump Screen on the Pump. Check strainers and remove
any trapped debris.
2. Flush Out Tank
The tank should be rinsed regularly, especially if using chemicals. Remove drain plug
(Part #351) and, using a garden hose, thoroughly flush tank and pump of any sediment.
3. Lubricate Main Motor
The main motor is a permanently lubricated motor, but it is beneficial to apply spray oil
around the shaft where it exits the motor body. Lubricate motor once a season or
whenever squealing occurs.
4. Inspect Blade Assembly
Clean the blade assembly about once a year, especially if a film of calcium or mineral
deposits is visible on the exterior of the blades. Remove any build-up from the blades
and any debris from blade passageways. While cleaning, inspect for irregularities or
hairline cracks and replace as necessary.
5. Storage
Protect your mobile Aquafog from winter damage. Expansion due to freezing can burst
the fittings or the internal feed pump. If storing unit in below freezing temperatures,
be sure all fluid is drained from the tank area. Damage due to freezing is not covered
under warranty.
DISCONNECT AND LOCK OUT POWER SOURCE
BEFORE SERVICING
WARNING
Summary of Contents for HRSM-1500