B

C

Ф6  drill bit

Step 1: Position the wall profile (No 1 ) onto the bath , approximately 12-15mm from the outside bath edge , ensuring that 

  the side with the pre-drilled holes are facing outwards from the bath  ( Diagram A). 

 

Step 2: Level the profile with a spirit level, then mark the position using a pencil through the 3 pre-drilled screw holes in the

            wall profile,drill the marked points using a 6mm masonry drill bit. Once this is done insert 3 wall plugs(No.2) (Diagram B). 

NOTE 

:Y

ou may find it easier to mark and drill the wall if you apply masking tape to it first.

Step 3: Secure the wall profile using 3 x ST4X30 screws (No.4) (Diagram C).

12-15mm

from bath 

    edge

4x30mm screws

A

D

G

F

E