1.1 Description of the function 

Apart  from  the  mechanical  water  treatment 

(filter / pool hydraulics), it is vital to control hy-

giene  parameters  such  as  pH  value  and  disin-

fectant  levels.  The  classical  method  of  manual 

measurement and correction is time-consuming 

and awkward. For the dosing unit to perform its 

task, there are some basic conditions which have 

to  be  met. They are described in  these instruc-

tions. You can use the control unit only for pri-

vate  swimming  pools  with  a  maximum  water 

volume of 65 m

3

 

1.2 pH-value and active oxygen  

The pH value is a key indicator of whether the 

water is acid, neutral or basic. A value of 7.2 has 

been found to be optimal for people and for the 

technology.  Moreover,  the  disinfectants  have 

their maximum effect at 7.2. 

Disinfection with active oxygen is especially ef-

fective in pools not very polluted (dirt, frequen-

cy of bathers, etc). Your pool professional must 

install a bigger-sized filtration equipment, as this 

alternative product has  a poorer effect in com-

parison with chlorine. Water temperature should 

not  exceed  of  28°  Centigrade.  With  a  higher 

temperature,  algae, viruses and bacteria can eas-

ily  proliferate.  Shall  your  hygiene  parameters  in 

the  pool  not  meet  your  demands  (despite  of  a 

regular dosing of active oxygen), we recommend 

a hyperchlorination to disinfect the pool again. 

Optimal  pool  hydraulics  are  just  as  important. 

This is because no disinfectants can enter areas 

where  the  water  cannot  be  circulated.  Algae 

growth  mainly  starts  in  the  corners  and  on  the 

bottom  of  the  pool.  Hence  depending  on  the 

amount of growth, walls and bottom have to be 

cleaned  mechanically  occasionally.  Dirt  is  col-

lected  inside  the  pre-filters  (skimmer  /  filter 

pump) too, and must be removed regularly. 

For the dosing unit to work optimally, the filter 

unit must  be switched  on at least 10 hours per 

day and backwash must be done at regular inter-

vals (1x per week). Fresh water input (automatic 

or  manual)  occurs  only  outside  the  running 

times  of  the  filter,  so  that  the  untreated  water 

cannot influence the measurements taken by the 

dosing technology. 

 

1.3 Installation 

The dosing unit must be installed in a dry room 

with  good  ventilation.  To  avoid  damage  if  the 

system  breaks  down,  there  must  be  a  drain  of 

sufficient  size.  The  control  unit  is  fixed  to  the 

wall with the fixing screws included in the scope 

of delivery. 

Please ensure that the suction pipe of the dosing 
pump  is  as  short  as  possible.  Hence  the  safety 
cans  are  placed  directly  under  the  device.  The 
suction lances must be screwed in the chemical 

tanks  and  connected  to  the  control  unit  using 
the plug. The injection valves for pH and disin-
fection are installed as shown on the installation 
diagram. The test water pipe is to be connected 
to the flow cell as shown in the installation dia-
gram.  

 

The mains cable and the temperature sensor 

have already been connected inside the con-

trol unit. The maximum permissible voltage 

is 230 V. The mains socket must be sited as 

close  as  possible  to  the  device  and  inter-

locked with the filter pump, that is, the elec-

tric  mains  socket  is  allowed  to  be  live  only 

when the filter pump is running. The swim-

ming  pool  installation  is  to  be  equipped 

with  a  separate  FI  switch.  Please  observe 

the  official  standards  for  wiring  regulations 

(i.e. German DIN VDE 0100) as well as lo-

cal  standards.  Ensure  that  the  mains  cable 

and  peripherals  are  not  live  during  installa-

tion or maintenance work.  

 

Page 23

 

1. Introduction

 

Summary of Contents for SL3 Deluxe 1,6 l/h

Page 1: ...2 19 Deutsch German DE 20 37 Englisch English UK 38 55 Franz sisch French FR 56 73 Niederl ndisch Dutch NL 74 91 Polnisch Polish PL 92 109 Russisch Russian RUS SL3 Deluxe 1 6 l h...

Page 2: ...im Betriebsmodus 2 2 Wechseln zwischen Betriebs und Einstellungsmodus 3 0 pH Wert Einstellungen 3 1 Sollwert 3 2 Min Alarm 3 3 Max Alarm 3 4 p Bereich 3 5 Nachstellzeit 3 6 Vorhaltezeit 3 7 min Stellg...

Page 3: ...Bedienfeld Display 2 Abdeckblende 3 Messwasseranschluss 4 pH Elektrode 5 Messwasserdurchflusszelle 6 Pumpe pH 7 Pumpe Desinfektion 8 Netzleitung Temperaturf hler und Anschluss f r Sauglanze 9 Durchfl...

Page 4: ...d 100 Min Stellgrad 15 Nachstellzeit 0 sec Vorhaltezeit 0 sec P Bereich 1 00 Max Alarm 7 60 Min Alarm 6 80 System Einstellungen Uhrzeit 09 00 00 Dosierzeit pH 120 min Verz gerung 8 min Datum Di 10 01...

Page 5: ...reinigt werden In Vorfiltern Skimmer Filter pumpe sammelt sich ebenfalls Schmutz an und muss regelm ig entfernt werden Damit die Dosieranlage optimal arbeiten kann muss die Filteranlage mindestens 10...

Page 6: ...uacontrol DOS SL 3 Wand Stockschraube Sauglanzendose Mutter D bel Wasserf hler mit Schelle an Rohr d 50 und d 63 angebaut Sauglanze pH Sauglanze Desinfektion Sauglanzenstecker Netzstecker Netz Tempera...

Page 7: ...ugleitung pH 2 Saugleitung Desinfektion 3 Messwasserentnahmestelle 4 Impfstelle pH 5 Impfstelle Desinfektion 6 Messwasserr ckf hrung 7 Druckseite nach Filter 8 Saugseite vor Pumpe 9 Kanister pH 10 Kan...

Page 8: ...Alarmwert ber oder unterschritten wurde Erscheint in einer Zeile Limit dann wurde die Sicherheitsabschaltung f r den jeweiligen Para meter aktiviert Deaktivierung siehe Kapitel 5 4 und Kapitel 5 5 Ein...

Page 9: ...egelung Untermen Durch Dr cken der Pfeil Tasten k n nen Sie im Untermen bl ttern Erscheint im Display die gew nschte Option die ver ndert werden soll dann dr cken Sie die OK Taste Im Display erscheint...

Page 10: ...ntile gereinigt werden Regelsteilheit Der Zahlenwert gibt den Proportionalbereich also die Regelsteilheit an bliche Werte sind 1 00 1 00 je nach Dosierrichtung Bedeutung Bei einem p Bereich von 1 00 a...

Page 11: ...te ausgew hlt Durch nochmaliges Best tigen mit der OK Taste wird die Kalibrierungsroutine aktiviert Nach 15 Sekunden zeigt der Regler kurz den Wert der verwendeten Pufferl sung an Danach wird die Sond...

Page 12: ...r d nnter Salzs ure und Pepsin einige Stunden L sungsmittel z B Aceton d rfen nicht zur Reinigung von Elektro den mit Kunststoffschaft verwendet wer den da dieser angegriffen werden kann Grunds tzlich...

Page 13: ...zt mit den Pfeiltasten ver n dert werden Zum Speichern des neuen Wertes dr cken Sie nochmals die OK Taste Ab bruch erfolgt durch Dr cken der Mode Tas te 4 1 Dosierung Aus Ein Aus Der Bedarf an Aktivsa...

Page 14: ...ertes dr cken Sie nochmals die OK Taste Abbruch erfolgt durch Dr cken der Mode Taste 5 1 Uhrzeit In diesem Men punkt wird die aktuelle Uhrzeit eingestellt 5 2 Verz gerung Entspricht der Startverz geru...

Page 15: ...den Werksseitig ist die Anlage auf IDS 2 eingestellt Eine nderung bzw eine Ausschaltung des IDS erfolgt im Untermen Systemeinstellungen W hlen Sie durch Dr cken der Pfeiltasten den Punkt IDS aus und b...

Page 16: ...ay Handsteuerung Die Do sierpumpe pH arbeitet mit maximaler Leistung Handsteuerung Desinfektion Bei Bedarf kann eine Zusatzdosierung f r Ak tivsauerstoff erfolgen Aus Beckengr e und Temperatur errechn...

Page 17: ...tigkeit Ca einmal pro Jahr ist der Pumpschlauch zu wechseln da dies ein Verschlei teil ist Gehen Sie dabei folgenderma en vor Die Saug und die Druckseite des Schlauches von Ihren Schlauchanschl ssen l...

Page 18: ...ufd sen 10 Skimmer 11 Bodenablauf 9 Sicherheitshinweis Die Sauglanzen zur Gebindeentnahme m ssen ensprechend der Beckengr e so positioniert werden dass bei einem Ausfall eines Schaltrelais eine berdos...

Page 19: ...s und Gesundheitsanforderungen der EU Richtlinie entspricht Bei einer nicht mit uns abgestimmten nderung des Produktes verliert diese Erkl rung ihre G ltigkeit Bezeichnung des Produktes Mess Regel und...

Page 20: ...e control unit 2 1 Display in operating mode 2 2 Changing between operating mode and set up mode 3 0 pH value settings 3 1 Setpoint pH 3 2 Min Alarm 3 3 Max Alarm 3 4 p band 3 5 I reset time 3 6 D act...

Page 21: ...2 3 4 1 Display 2 Cover plate 3 Test water terminal 4 pH electrode 5 Flow cell for test water 6 pH pump 7 Disinfection pump 8 Mains supply temperature sensor and terminal for suction lance 9 flow moni...

Page 22: ...00 Min Output 15 I reset time 0 sec D action time 0 sec P band 1 00 Max Alarm 7 60 Min Alarm 6 80 System settings Time 09 00 00 Dosing time pH 120 min Delay 8 min Date Sun 21 01 2022 IDS 2 Mode Disinf...

Page 23: ...cally occasionally Dirt is col lected inside the pre filters skimmer filter pump too and must be removed regularly For the dosing unit to work optimally the filter unit must be switched on at least 10...

Page 24: ...Fixing screws Suction lance socket Nut Dowel Water sensor with clamp fitted to pipe d 50 and d 63 Suction lance pH Suction lance disinfection Suction lance plug Mains plug Power Temperature S D Sketc...

Page 25: ...pipe disinfection 3 Test water outlet 4 Injection valve pH 5 Injection valve disinfection 6 Return test water 7 Return pipe after filter 8 Suction pipe before pump 9 Chemical tank pH 10 Chemical tank...

Page 26: ...ing pumps are activated The arrow before the of dosing performance means that an alarm value has been exceeded or undershot If Limit appears in a line the security switch off for the parameter concern...

Page 27: ...ub menu You c an s c r o l l through the sub menu by pressing the arrow keys When the option you want to change appears in the display press the OK key A star appears in the display The value can now...

Page 28: ...n slope The figure gives the p band ie the regulation slope Usual values are 1 00 1 00 depending on dosing direction Meaning For a p band of 1 00 the dosing pump works at full performance when the mea...

Page 29: ...pH 7 buffer used it can be corrected to pH 7 using the ar row keys Afterwards take the probe out of the first buff er solution and if possible rinse it in water and dry it off using a dry paper towel...

Page 30: ...tone Biological deposits Solution of diluted hydro chloric acid and pepsin several hours solvents eg acetone must not be used to clean electrodes with plastic shaft as the shaft can be attacked by suc...

Page 31: ...sing the Mode key Caution the options Start dosing and Pool size can only be modified when the dosing is on position ON 4 1 Dosing Off On Off The unit will dose daily the quantity of active oxygen nee...

Page 32: ...tem start the dosing is blocked until the delay has expired Role of thumb Time delay in minutes Backwash time 2 min The dosing time limitation prevents dangerous faulty dosing if an electrode fails Th...

Page 33: ...sons in most cases The system is set to IDS 2 in the factory The IDS can be altered or switched off in the system settings submenu Press the Arrow keys to select the IDS item and confirm this with OK...

Page 34: ...rdosing Reason When a water treatment product is pumped into the nozzle pipe depending on the pool hydraulics there can be a time delay before the water with treatment product reaches the measuring ce...

Page 35: ...leaks Change the pump hose ca once a year as it is a spare part Proceed as follows Disconnect the suction and return sides of the pump from their hose connections Loosen the fastening screw of the tra...

Page 36: ...ion lances for taking product from the container must be positioned appropriately to the size of the pool so that overdosing is im possible even if a relay should malfunction It is necessary to ensure...

Page 37: ...ty and health requirements of the EU Directive In the event of a change to the product not agreed with us this declaration shall lose its validity Designation of the product Measuring control and dosi...

Page 38: ...ement 2 2 Commutation entre le mode de fonctionnement et le mode de r glage 3 0 Valeur pH R glages 3 1 Valeur de consigne 3 2 Alarme min 3 3 Alarme max 3 4 Plage P 3 5 Temps de r ajustement 3 6 Temps...

Page 39: ...neau de commande cran 2 Cache 3 Raccord d eau de mesure 4 lectrode pH 5 Cellule de d bit d eau de mesure 6 Pompe pH 7 Pompe D sinfection 8 C ble d alimentation sonde de temp rature raccordement pour l...

Page 40: ...ax 100 Taux de modulation min 15 Temps de r ajuste ment 0 sec Temps de d rivation 0 sec Plage P 1 00 Alarme max 7 60 Alarme min 6 80 Syst me R glages Heure 09 00 00 Temps de dosage pH 120 min D lai 8...

Page 41: ...e syst me de dosage puisse fonction ner de mani re optimale l installation de filtrage doit tre mise en marche au moins 10 heures par jour et un r trolavage doit tre effectu inter valles r guliers 1 f...

Page 42: ...uble filetage Bo tier de la lance d aspiration crou Cheville Sonde eau mont e avec collier sur le tube d 50 et d 63 Lance d aspiration pH Lance d aspiration D sinfection Fiche de la lance d aspiration...

Page 43: ...spiration D sinfection 3 Point de pr l vement d eau de mesure 4 Point d inoculation pH 5 Point d inoculation D sinfection 6 Retour de l eau de mesure 7 C t pression apr s le filtre 8 C t aspiration av...

Page 44: ...fie qu une valeur d alarme a t d pass e vers le haut ou vers le bas Si Limit appara t sur une ligne cela signifie que la coupure de s curit a t activ e pour le param tre concern Pour la d sactivation...

Page 45: ...u r l e s touches fl ch es on fait d filer le sous menu Si l option souhait e modifier appara t l cran appuyer sur la touche OK Une toile appara t l cran La valeur peut maintenant tre modifi e l aide...

Page 46: ...valves d inoculation nettoy es Pente de r gulation La valeur num rique indique la plage propor tionnelle c est dire la pente de r gulation Les valeurs habituelles sont 1 00 1 00 selon le sens de dosag...

Page 47: ...ne nouvelle fois avec la touche OK la routine de calibrage est activ e Apr s 15 secondes le r gulateur affiche la valeur de la solution tampon utilis e Retirer ensuite la sonde de la premi re solution...

Page 48: ...ique dilu et de pepsine quelques heures les solvants par ex l ac tone ne doivent pas tre utilis s pour nettoyer les lectrodes avec tige en plastique car celle ci risque d tre attaqu e En principe il f...

Page 49: ...trer la nouvelle valeur appuyer nouveau sur la touche OK Pour annuler il suffit d ap puyer sur la touche Mode 4 1 Dosage arr t marche Arr t Les besoins en oxyg ne actif sont ajout s quotidiennement au...

Page 50: ...la touche OK Pour annuler il suffit d ap puyer sur la touche Mode 5 1 Heure Ce point de menu permet de r gler l heure ac tuelle 5 2 Temporisation Correspond la temporisation de d marrage du r gulateur...

Page 51: ...n est r gl e en usine sur IDS 2 Une modification ou une d sactivation de l IDS s ef fectue dans le sous menu R glages du syst me S lectionner l option IDS en appuyant sur les touches fl ch es et confi...

Page 52: ...pompe de dosage pH fonctionne la puissance maximale Commande manuelle D sinfection Si n cessaire un dosage suppl mentaire d oxy g ne actif peut tre effectu Le r gulateur cal cule la dur e de fonctionn...

Page 53: ...ords du tuyau Le tuyau de pompe doit tre remplac environ une fois par an car il s agit d une pi ce d usure Pour ce faire proc der comme suit D tacher le c t aspiration et le c t pression du tuyau des...

Page 54: ...ntr e 10 cumeur 11 Siphon de sol 9 Consignes de s curit Les lances d aspiration pour la prise de r cipient doivent tre positionn es en fonction de la taille du bassin de mani re ce qu un surdosage soi...

Page 55: ...curit et de sant de la directive europ enne En cas de modification du produit non convenue avec nous la pr sente d claration perd sa validit D signation du produit Syst mes de mesure de contr le et de...

Page 56: ...eergaven in bedrijfsmodus 2 2 Wisselen tussen bedrijfs en instelmodus 3 0 Instellingen pH waarde 3 1 Instelwaarde 3 2 Min alarm 3 3 Max alarm 3 4 p bereik 3 5 Nasteltijd 3 6 Voorstoptijd 3 7 Min uitga...

Page 57: ...Bedieningspaneel display 2 Afdekpaneel 3 Meetwateraansluiting 4 pH elektrode 5 Meetwaterdoorstromingscel 6 Pomp pH 7 Pomp desinfectie 8 Netsnoer temperatuurvoeler aansluiting voor zuiglans 9 Doorstrom...

Page 58: ...ni veau 100 Min uitgangsni veau 15 Nasteltijd 0 sec Voorstoptijd 0 sec P bereik 1 00 Max alarm 7 60 Min alarm 6 80 Systeem Instellingen Tijd 09 00 00 Doseertijd pH 120 min Vertraging 8 min Datum Di 10...

Page 59: ...dem daarom mechanisch worden gereinigd Ook in de voorfilters skimmer filterpomp hoopt zich vuil op en dit moet regelmatig worden verwijderd Om de doseerinstallatie optimaal te laten werken moet het fi...

Page 60: ...ng Aquacontrol DOS SL 3 Wand Stokschroef Zuiglansdoos Moer Plug Watersensor met klem aan leiding bevestigd d 50 en d 63 Zuiglans pH Zuiglans desinfectie Zuiglansstekker Netstekker Net Temperatuur S D...

Page 61: ...uigleiding pH 2 Zuigleiding desinfectie 3 Afnamepunt meetwater 4 Injectiepunt pH 5 Injectiepunt desinfectie 6 Meetwaterretour 7 Drukzijde na filter 8 Zuigzijde voor pomp 9 Jerrycan pH 10 Jerrycan desi...

Page 62: ...teit betekent dat er een alarmwaarde over of onderschreden werd Als er Limit in een regel verschijnt is de veiligheidsuitschakeling voor de betreffende parameter geactiveerd Voor deactivering zie hoof...

Page 63: ...de pijltoetsen te d r u k k e n kunt u in het s u b m e n u bladeren Als in het display de gewenste optie verschijnt die gewijzigd moet worden drukt u op de OK toets In het display verschijnt een ste...

Page 64: ...Door nogmaals te bevestigen met de OK toets wordt de kalibratieroutine geactiveerd Na 15 seconden toont de regelaar kort de waarde van de gebruikte bufferoplossing Daarna wordt de sonde uit de eerste...

Page 65: ...worden gereinigd Regelsteilheid De numerieke waarde geeft het proportionele bereik aan d w z de regelsteilheid Gebruikelijke waarden zijn 1 00 1 00 afhankelijk van de doseerrichting Betekenis Bij een...

Page 66: ...ur om elektroden met een kunststof schacht te reinigen mogen geen oplosmiddelen zoals aceton worden gebruikt omdat ze daardoor kunnen worden aangetast In principe moet na elke reiniging voldoende word...

Page 67: ...n gewijzigd Om de nieuwe waarde op te slaan drukt u nogmaals op de OK toets U kunt annuleren door op de Mode toets te drukken 4 1 Dosering Uit Aan Uit De benodigde actieve zuurstof wordt dagelijks aan...

Page 68: ...aals op de OK toets U kunt annuleren door op de Mode toets te drukken 5 1 Tijd In dit menu item wordt de huidige tijd ingesteld 5 2 Vertraging Komt overeen met de startvertraging van de regelaar in mi...

Page 69: ...dsuitschakeling Het systeem is in de fabriek ingesteld op IDS 2 Het IDS kan worden gewijzigd of uitgeschakeld in het submenu Systeeminstellingen Selecteer door op de pijltoetsen te drukken het IDS pun...

Page 70: ...lay Handmatige besturing De doseerpomp pH werkt met maximale capaciteit Handmatige besturing desinfectie Indien nodig kan een extra dosering actieve zuurstof worden gedaan De regelaar berekent de loop...

Page 71: ...slangaansluitingen op lekkage De pompslang moet ongeveer n keer per jaar worden vervangen omdat dit een slijtdeel is Ga hiervoor als volgt te werk Maak de slang aan zuig en drukzijde los van de slanga...

Page 72: ...uk 10 Skimmer 11 Bodemafvoer 9 Veiligheidsaanwijzing De zuiglansen voor verwijdering uit de containers moeten overeenkomstig de grootte van het zwembad zodanig worden geplaatst dat overdosering bij he...

Page 73: ...zondheidseisen van de EU richtlijn In geval van een wijziging van het product die niet met ons is overeengekomen verliest deze verklaring haar geldigheid Benaming van het product Meet regel en doseers...

Page 74: ...2 2 Prze czanie pomi dzy dwoma trybami pracy i tryb ustawiania 3 0 Regulacja wsp czynnika pH 3 1 Warto zadana 3 2 Alarm minimum 3 3 Alarm maksimum 3 4 Zakres p 3 5 Czas wyregulowania 3 6 Czas podtrzy...

Page 75: ...l sterowania wy wietlacz 2 os ona 3 przy cze wody pomiarowej 4 elektroda pH 5 kom rka przep ywu wody pomiarowej 6 pompa pH 7 pompa rodka dezynfekuj cego 8 przew d sieciowy czujnik temperatury przy cze...

Page 76: ...Maks stop regul 100 Min stop regul 15 Cz wyregul 0 s Cz podtrz 0 s Obszar P 1 00 Maks alarm 7 60 Min alarm 6 80 System Ustawienia Czas zegarowy 09 00 00 Czas dozowania pH 120 min Zw oka 8 minut Data...

Page 77: ...w filtrach wst pnych zgarniacz pompa filtracyjna i musz by regularnie usuwane Aby instalacja dozuj ca mog a funkcjonowa optymalnie system filtracyjny musi by w czony przez co najmniej 10 godzin dzienn...

Page 78: ...OS SL 3 ciana ruba dwustronna gniazdo lancy ss cej nakr tka ko ek rozpr ny czujnik wody zamocowany opask na rurze d 50 i d 63 lanca ss ca pH lanca ss ca dezynfekcji wtyczka lancy ss cej wtyczka siecio...

Page 79: ...ew d ss cy dezynfekcji 3 punkt poboru wody pomiarowej 4 stanowisko iniekcji pH 5 stanowisko iniekcji dezynfekcji 6 powr t wody pomiarowej 7 strona t oczna za filtrem 8 strona ss ca przed pomp 9 kanist...

Page 80: ...tla aktualnie zmierzone warto ci i w razie potrzeby aktywuje pompy Strza ka przed procentowym wska nikiem dozowania oznacza e warto alarmowa zosta a przekroczona lub spad a poni ej warto ci minimalnej...

Page 81: ...lacji pH Podmenu Przy pomocy przycisk w nawigacji ze strza k mo na kartkowa w podmenu Gdy na wy wietlaczu pojawia si opcja kt r nale y zamieni nale y wcisn przycisk OK Na wy wietlaczu pojawia si gwiaz...

Page 82: ...przew d dozuj cy musi by p ukany wod a zawory iniekcyjne musz by czyszczone Nachylenie krzywej regulacji Warto liczbowa podaje zakres proporcjonalno ci czyli nachylenie krzywej regulacji Typowe warto...

Page 83: ...edura kalibracji jest aktywowana przez ponowne potwierdzenie przyciskiem OK Po 15 sekundach regulator wy wietla przez chwil warto u ytego roztworu buforowego Nast pnie wyj sond z pierwszego roztworu b...

Page 84: ...r rozcie czonego kwasu solnego i pepsyny kilka godzin rozpuszczalnik np aceton nie mo e by stosowany do czyszczenia elektrod z rdzeniem z tworzywa sztucznego gdy mo e on zosta uszkodzony Zasadniczo po...

Page 85: ...y przycisk w nawigacji ze strza kami eby zapisa now warto ponownie nacisn przycisk OK Wci ni cie przycisku trybu Mode powoduje anulowanie 4 1 Dozowanie WY ZA WY Potrzebna ilo aktywnego tlenu jest doda...

Page 86: ...ie przycisku trybu Mode powoduje anulowanie 5 1 Czas zegarowy W tym punkcie menu ustawia si aktualny czas zegarowy 5 2 Zw oka Op nienie w czania regulatora jest wskazane w minutach Po ka dym starcie i...

Page 87: ...Fabrycznie instalacja jest ustawiona na IDS 2 IDS mo na zmieni lub wy czy w podmenu Ustawienia systemowe Wciskaj c przyciski nawigacji ze strza k wybra punkt IDS i potwierdzi przyciskiem OK Mo na wybr...

Page 88: ...etlaczu pojawi si komunikat Sterowanie r czne Pompa dozuj ca pH pracuje z maksymaln wydajno ci Sterowanie r czne Dezynfekcja W razie potrzeby mo liwe jest dodatkowe dozowanie aktywnego tlenu Sterownik...

Page 89: ...ki transportuj cej Szczelno w a pompy Przy cza w y pod k tem szczelno ci W pompy nale y wymienia mniej wi cej raz w roku poniewa jest to cz zu ywaj ca si Post powa przy tym w nast puj cy spos b Od czy...

Page 90: ...8 stanowisko iniekcji dezynfekcji 9 dysze dop ywu 10 zgarniacz 11 Kratka ciekowa 9 Wskaz wka bezpiecze stwa W zale no ci od wielko ci basenu lance zasysaj ce z kanistra musz by umieszczone tak eby w...

Page 91: ...ze stwa i ochrony zdrowia okre lonymi w dyrektywie UE W przypadku nieuzgodnionej z nami zmiany produktu niniejsza deklaracja traci wa no Oznaczenie produktu Systemy pomiarowe kontrolne i dozuj ce do b...

Page 92: ...ontrol DOS SL 3 Deluxe 1 6 01 2022 pH 2022 CE 1 0 1 1 1 2 pH 1 3 2 0 2 1 2 2 3 0 pH 3 1 3 2 Min Alarm 3 3 Max Alarm 3 4 3 5 3 6 3 7 3 8 3 9 pH 3 10 3 11 4 0 4 1 4 2 4 3 4 4 5 0 5 1 5 2 5 3 pH 5 4 IDS...

Page 93: ...93 Aquaconsulting Aquacontrol DOS SL 3 1 2 3 4 pH 5 6 pH 7 8 9 9 8 7 6 5 4 3 2 1...

Page 94: ...94 Aquaconsulting Aquacontrol DOS SL 3 pH pH 07 20 00 100 15 0 0 1 00 7 60 6 80 09 00 00 pH 8 10 01 2022 1 09 00 IDS 2 OK...

Page 95: ...1 1 pH 65 3 1 2 pH pH 7 2 28 C 10 1 3 pH 230 VDE 0100 95 Aquaconsulting Aquacontrol DOS SL 3 1...

Page 96: ...96 Aquaconsulting Aquacontrol DOS SL 3 d 50 d 63 pH S D B C...

Page 97: ...97 Aquaconsulting Aquacontrol DOS SL 3 2 1 5 4 10 7 9 8 6 3 1 pH 2 3 4 pH 5 6 7 8 9 pH 10...

Page 98: ...2 1 pH pH pH pH 2 2 Limit 5 4 5 5 Mode Mode Swimtec pH 7 20 0 10 10 19 C 0 pH 0 9 20 20 C 0 pH 7 20 0 10 10 19 C 0 pH pH 7 80 60 9 20 20 C 0 pH 7 80 9 20 20 C 98 CE 2...

Page 99: ...99 Aquaconsulting Aquacontrol DOS SL 3 pH pH pH Mode pH OK pH pH Mode pH 1 100 1 15 1 0 1 0 1 1 00 1 7 60 1 6 80 1 pH OK 1 07 20 00 1 SN6 pH pH...

Page 100: ...0 pH pH pH pH 3 4 3 2 Min Alarm 6 80 3 3 Max Alarm 7 60 3 4 1 00 pH 1 00 pH 1 00 pH pH pH 1 00 1 00 1 00 D1 pH D 0 5 pH 50 3 5 0 3 6 0 3 7 15 15 15 15 3 8 100 80 80 80 100 Aquaconsulting Aquacontrol D...

Page 101: ...101 Aquaconsulting Aquacontrol DOS SL 3 3 9 pH pH pH 7 15 pH 4 15 pH 4 pH pH pH 7 OK 12 pH 7 OK pH 4 OK 10 pH 4 OK...

Page 102: ...102 Aquaconsulting Aquacontrol DOS SL 3 3 10 pH 7 pH 4 pH pH 3 11 0 1 3 1 5 3 3...

Page 103: ...09 00 00 1 103 Aquaconsulting Aquacontrol DOS SL 3 4 Mode Kanal 2 OK Mode 4 1 4 2 09 00 4 3 1 1 4 4 10 24 520 25 520 26 620 27 700 28 800 29 880 30 980 31 980 pH OK...

Page 104: ...104 Aquaconsulting Aquacontrol DOS SL 3 5 Mode OK Mode 5 1 5 2 2 5 3 1 pH 60 1 6 1 6 pH Limit pH 8 09 00 00 8 8...

Page 105: ...105 Aquaconsulting Aquacontrol DOS SL 3 5 4 IDS pH pH IDS IDS 2 IDS IDS OK IDS IDS pH IDS 1 IDS 2 45 1 6 IDS 3 45 1 6 IDS IDS 3 IDS 2 IDS 1...

Page 106: ...106 Aquaconsulting Aquacontrol DOS SL 3 pH pH Mode OK pH Handsteuerung pH MODE 6 Mode Regler Stoppen OK gestoppt pH OK 7...

Page 107: ...107 Aquaconsulting Aquacontrol DOS SL 3 1 pH pH4 pH7 3 9 2 pH pH 3 8...

Page 108: ...10 108 Aquaconsulting Aquacontrol DOS SL 3 8 5 6 2 3 10 7 0 5 9 9 4 1 11 1 2 3 4 5 6 7 pH 8 9 10 11 9...

Page 109: ...control Gesellschaft f r Mess Regel und Steuerungstechnik zur Wasseraufbereitung mbH Champagne 7 D 42781 Haan DOS CL2 Deluxe DOS CL2 Deluxe Salt DOS SL3 Deluxe 2014 35 EU 2014 30 EU 01 01 2022 Josef S...

Reviews: