background image

TM Reverse Osmosis Water Filtration System

 

Product Code: SYS-RO924TM5 

Page 

7

 of 

15

 

 

 

9.

 

Reset LED indicator by following instructions on page 10. 

10.

 

Install the drain clamp by drilling a 4 mm hole in the waste pipe. Position the drain 
clamp above the trap. 

Connect ¼” BLACK drain tube to drain clamp 

and tighten 

compression nut. Do not allow drain hose to protrude more than 10 mm into drain, 
making sure the holes in the drain and the clamp are exactly aligned. This can be 
done by inserting a thin Phillips screwdriver through them whilst tightening the 
clamp. (Fig 5) 

11.

 

When connecting the red, black, blue and white tubes leave plenty of extra 
length so that the purifier can be repositioned during servicing without having to 
disconnect all the hoses. 

12.

 

Connect WHITE tube to storage tank.

 Screw ball valve to tank outlet and ensure valve 

is open. (Fig 6)

 

13.

 

Once unit has been completely plumbed it will need to be actuated. To do this ensure 
isolation valve is off and faucet is open. Gradually open isolation valve to begin water 
production. The first sign will be water running to drain. This is normal and then finally 
product water will begin coming out faucet. This may take several minutes.

 

a.

 

At this stage close faucet. This forces product water to fill up the storage 
tank. To check that water is still being produced, check water is running to 
drain. This should continue for several hours until tank is full. When tank is 
full, the pressure in the tank will overcome the inlet water pressure and the 
shut off valve will activate, shutting off the inlet water. To check this, check if 
water is running to drain. Once tank is full, no water should run to drain. To flush 
system, allow tank to fill, open faucet outlet until water stops, close faucet and allow tank to fill. Check all 
connections for leaks. 

14.

 

Reverse osmosis systems produce water slowly, almost drop to drop. If the tank is empty to begin with, it will take the tank 
3 to 4 hours to fill. Reverse osmosis systems product water slowly. Initially filling the tank will take 3 - 4 hours. Fill and 
empty twice before drinking water from the system. This is essential in order to flush away any sterilising solution in the 
membrane. 

15.

 

Check all connections are tightened properly. Check for leaks. 

16.

 

To dispense drinking water from the faucet, push and hold the handle down or push up for continuous operation. 

17.

 

When the unit is in place and the water lines are installed, the unit should be run for 4 hours before the purified water is 
used, on initial start up. The unit cannot be stored for more than 2 weeks without use, or damage to the membrane may 
occur. Please enquire if this is the case. For a period of non-use greater than 2 days, flush for 10 minutes before use. For 
non-use periods of more than 2 weeks, the cartridges may need replacing. 

18.

 

The sediment and chemical removal filters should be replaced every 12 months. The membrane should be replaced when 
water quality deteriorates or every 36 - 48 months, depending on incoming water quality. Use only genuine AquaCo 
replacement cartridges and cartridges that are suitable for this appliance. 

 

 

 

 

 

Figure 5

 

Figure 6

 

Summary of Contents for SYS-RO924TM5

Page 1: ...rse Osmosis Water Filtration System Product Code SYS RO924TM5 Page 1 of 15 WARNING For correct operation installation it is essential to observe these instructions TM REVERSE OSMOSIS WATER FILTRATION...

Page 2: ...lation 4 Installation requirements 4 Typical Installation 5 Installation Procedure 6 Cartridge Installation Maintenance 8 Membrane Service Maintenance 9 Alkalising Inline Service Maintenance 9 Faucet...

Page 3: ...ockist Customer Service Helpline 08 6156 0220 Australia OPERATION The AquaCo reverse osmosis systems are designed to run economically for many years dependent on the initial installation and periodica...

Page 4: ...ded is a control valve incorporating backflow prevention anti hammer flow control and pressure limiting capabilities in full compliance with the relevant laws INSTALLATION REQUIREMENTS 1 13 mm Cold wa...

Page 5: ...ter Hose Not included PLV Pressure Limiting Valve Housing Sump with 1st Stage Filter Sediment Pre Filter Housing Sump with 2nd Stage Filter Carbon Block Auto Shut Off Valve 1 4 Male Elbow Membrane Hou...

Page 6: ...ith the cold water line As pictured the valve is in the off position During this point you can turn the water back on to check for leaks in the valve installation 6 Select location on kitchen sink to...

Page 7: ...vercome the inlet water pressure and the shut off valve will activate shutting off the inlet water To check this check if water is running to drain Once tank is full no water should run to drain To fl...

Page 8: ...ng housings place a container underneath to catch any spillage See Fig 7 Figure 7 4 Cleanse the inside of the housing using warm water Check O ring and lubricate with food grade silicone lubricant or...

Page 9: ...then turn on the faucet letting the air out of the system and flushing the membrane Repeat the flushing process at least one time waiting at least 2 hours between each procedure ALKALISING INLINE SER...

Page 10: ...13 2 Install battery into the battery seat positive side up discard plastic insert Figure 12 3 Reinstall battery seat assembly into the faucet lever battery side facing outwards 4 Blue light flashes d...

Page 11: ...ing to local plumbing codes on the cold water line Replacement Cartridges See Cartridge replacement section This system requires regular replacement of the filter cartridge to maintain proper operatio...

Page 12: ...t Stage Sediment Filter PP 925 1 2nd Stage Carbon Filter CB 925 5 3rd Stage 75 GPD Membrane MEM 75GPD 4th Stage Carbon Filter CB 925 5 5th Stage Alkalising Filter IL 1125BB ALK TO MAINTAIN THE HIGH QU...

Page 13: ...orine Reduction 95 45 000 L 0 75 gpm Initial _P 5 0 psid 0 75 gpm Carbon Weight 0 80 lbs Carbon Type Activated Carbon NOTES CHLORINE REDUCTION CAPACITY BASED ON LABORATORY TESTING CONDUCTED USING TEST...

Page 14: ...from date of purchase The 5 year warranty comprises 1 year in parts and labour plus 4 years in parts only To make a claim under the warranty take the product and proof of purchase to place where you...

Page 15: ...provided in addition to other rights and remedies you have under law Our goods come with guarantees which cannot be excluded under the Australian Consumer Law You are entitled to replacement or refund...

Reviews: