- 7 - 

 

open the flushing valve totally. After flushing close the 
valve carefully - without power. In operation minimum 
three times more brine flows than pure water!  

Careful maintenance increases the life time of the 
reverse osmosis membrane.

 An automatically driven 

flushing valve can be mounted to the unit - even after 
installation of the mounting board. 

Monthly flushing of the unit 

To increase the life time of the membrane please flush the 
reverse osmosis unit every month for 15 to 30 minutes. 
Open the flushing valve totally and prove the water 
outflow. If the water do not runs out of the brine tube for 
minimum 5 liters per minute check the pre filter(s) or the 
water pressure.  
After flushing close the flushing valve. 

Attention: the 

flushing valve do not shut totally! Do not close it 
tightly! Otherwise the correct function of the reverse 
osmosis unit is not guaranteed.

 

Maintenance every four month -  

change of the pre filter(s) 

Check the condition of the pre filter(s)

. Blocked filters 

reduces water flow and increases the quality of the pure 
water enormously. If the pre filter is not changed for a 
long time the membrane can be destroyed. 
To check the pre filter shut of the water tap and release the 
pressure from the unit (wait for a minute). Unscrew the 
housing of the 10" pre filter (9). Take off the filter 
cartridge (10) and lock at its color and condition. If the 
color is brown, red or black and smells, the cartridge has 
to be changed. Therefore put a new filter into the filter 
housing and screw the housing at the top. Do not forget 
the ring seal. 
The combi filter has a normal life time of 6 to 12 months. 
If the life time is shorter than 6 month use a score filter 
before the combi filter.  

Check the water flow.

    

Therefore you need a measuring cylinder and a watch with 
seconds. Start the reverse osmosis unit. After flushing the 
flushing valve operated the unit for minimum 10 minutes. 
Then fill the pure water into the cylinder. Take the time 
after 1 liter pure water. Calculate the water flow with the 
formula: 

water flow

volume

time

in litre / day

in litre

in minutes

=

1440

 

Write the date, the feed water pressure (manometer 
optional) and the calculated pure water flow into a 
maintenance plan. With the same method you must 
evaluate the flow of the brine (closed flushing valve) and 
write the value into the plan. With the following formula 
you are able to calculate the ratio brine flow / pure water 
flow: 

ratio

brine flow

permeate flow

brine : permeate

=

 

 

Now you have to check the quality of the pure water. 

The best method of measuring is the determination of the 
electrical conductivity. You can also determine the water 
hardness by quick test. Please use the instruction manuals 
of these test. If you have determined the conductivity or 
the hardness write the value into the maintenance plan. 
Test the quality of the feed water in the same way. 

Now you are able to calculate the rejection: 

rejection

conductivity pure water

conductivity feed water

in %

= −

(

)

1

100

 

or 

rejection

hardness pure water

hardness feed water

in %

= −

(

)

1

100

 

If the calculation is to complicated please use the 
following table. Please chose the line with the conductivity 
or water hardness of your feed water (for example 
500 µS/cm). In the 2nd row you see the values that are o.k. 
for the pure water (in that example 50 to 15 µS/cm). If the 
water quality is too bad (conductivity is higher than the 
values in the 2nd row), the reverse osmosis membrane has 
a rejection below 90%. Please see "faults". 

conductivity feed water

conductivity permeate in µS/cm

in µS/cm

with good membrane

100

10

to

3

200

20

to

6

500

50

to

15

750

75

to

23

1000

100

to

30

1250

125

to

38

1500

150

to

45

hardness feed water

hardness permeate in °dH

in °dH

with good membrane

2

0,2

to

0,1

5

0,5

to

0,2

7

0,7

to

0,2

10

1,0

to

0,3

15

1,5

to

0,5

20

2,0

to

0,6

25

2,5

to

0,8

 

Storing a reverse osmosis membrane /  

changing a membrane  

Storing a reverse osmosis membrane 

 

You can stop an AquaCare reverse osmosis unit for a long 
time without defects at the membrane. To prevent a big 
bacteria growth (smell) on the membrane and on the pre 
filter(s) it is better to make some steps before stopping the 
unit for more than 4 weeks.  
First stop the unit by closing the water tap. If there is no 
water pressure in the unit (after c. 30 seconds), open the 
pre filter(s) and drain the water. The pre filters may dry. 
It is not allowed to dry the membrane. It would be 
destroyed. Please disassemble all tubes from the 
membrane housing (11) and close the open connections 
with plugs (red plugs for inlet and permeate outlet, with 
plug for brine). Now open the membrane housing and 
drain the water. The next step is to fill the housing with 
AquaCare disinfection solution (50 to 100 ml) and to close 
the housing. Now the membrane can be stored for many 
months without bacterial growth.  

Important! Never store the membrane below 0°C 
(30°F)! Ice destroys the membrane. 

If you want to reuse the reverse osmosis unit please open 
the membrane housing, drain the disinfection solution and 
assemble the plant (see "Putting into operation"). 

Changing the membrane 

 

If the membrane (12) is not in order you have to change it. 
Therefore stop the unit and open the membrane housing 
(11). Pull the old membrane out of the housing and push 
the new one into it (first the part with the small ring 

Summary of Contents for Excel 1000 1:1

Page 1: ...e water outlet C Abwasserausgang Waste water outlet 1 Flachdichtung Seal 2 Muffe i i Muffle i i 3 Fitting a 6i Fitting a 6i 4 Wasserhahnanschluss Tap water connector 5 6 mm PE Schlauch 6 mm PE tube 6...

Page 2: ...hadstoffen angereicherte Teil des Wassers vor der Membran abgeleitet werden Abwasser Konzen trat Die Reinwasserqualit t und leistung einer Umkehr osmoseanlage wird von mehreren Faktoren beeinflusst Je...

Page 3: ...n den Deckel wieder auf das Geh use ffnen Sie den Wasserhahn Rohwasser die Luft ent weicht aus der Anlage Nachdem ein gleichm iges Rau schen zu h ren ist schlie en sie das Sp lventil 20 Ach tung Venti...

Page 4: ...Zeile mit dem Leitwert H rte der Ihrem Leitungswasser am besten entspricht Wenn z B Ihr Leitungswasser einen Leitwert von 550 S cm hat gehen Sie in die Zeile 500 S cm Das Reinwasser darf dann h chste...

Page 5: ...mit Vaseline ein Sollten die O Ringe Risse oder Macken aufweisen m ssen sie ersetzt werden berpr fen Sie ob in der Geh useaufnahme des Membran sammelrohrs ein Riss ist Wenn ja muss das Membrange h us...

Page 6: ...stone minimum 30 mm deep Push the plugs into the holes and use the screws to fix the board at the wall If you want to fix it on wood or plastic drill holes with diameters between 2 5 and 3 0 mm Then c...

Page 7: ...uring is the determination of the electrical conductivity You can also determine the water hardness by quick test Please use the instruction manuals of these test If you have determined the conductivi...

Page 8: ...tes and close it If the brine do not run please change the flushing valve Too much pure water and to low rejection Check the seals at the pure water collector at the membrane If they are not in order...

Page 9: ...R 087x3 5N Membranen membranes Excel 600 300 GPD 190 075 Modulgeh use 2812 membrane housing 2812 191 106 Halter clip 191 102 Halter clip 191 107 PE Schl uche PE tubes PE06 4rt PE06 4bl PE06 4sw Flachd...

Page 10: ...Membrantyp Type of Membran Wickelmodul spiral wound Membranmaterial Material of membrane Polyamid TFC Membrangr e Excel 90 Excel 160 Excel 180 1 1 Excel 320 Excel 360 1 1 Excel 480 Excel 1000 1 1 Memb...

Reviews: